Title: A modified balance chart -- ordering and charting intravenous fluids by "B numbers". Author: Leigh JM. Journal: Eur J Intensive Care Med; 1976 Nov; 2(3):131-3. PubMed ID: 991866. Abstract: Most difficulties with intravenous fluid charting are due to the inability to identify which bottle/bag on the balance sheet corresponds to the bottle/bag on the order sheet. These can be eliminated by allocating every bottle/bag a number in sequence and charting intravenous fluids in START and FINISH columns against a time scale. Accumulation of the Running Total minimises arithmetical errors as only two numbers are added together on any one occasion. A definitive balance form and order sheet, printed on both sides of a single sheet of A4 paper illustrates the "B Number" method with a reasonably complicated example of fluid balance.[Abstract] [Full Text] [Related] [New Search]