These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
1058 related items for PubMed ID: 10096477
1. Eighteen-year follow up after Hancock II bioprosthesis insertion. Legarra JJ, Llorens R, Catalan M, Segura I, Trenor AM, de Buruaga JS, Rabago G, Sarralde A. J Heart Valve Dis; 1999 Jan; 8(1):16-24. PubMed ID: 10096477 [Abstract] [Full Text] [Related]
2. Evaluation of valve-related complications in patients with Sorin Bicarbon prosthesis: a seven-year experience. Bortolotti U, Milano A, D'Alfonso A, Piccin C, Mecozzi G, Magagna P, Fabbri A, Mazzucco A. J Heart Valve Dis; 2001 Nov; 10(6):795-801. PubMed ID: 11767189 [Abstract] [Full Text] [Related]
3. Clinical evaluation of the carbomedics prosthesis: experience at providence health system in Portland. Minakata K, Wu Y, Zerr KJ, Grunkemeier GL, Handy JR, Ahmad A, Starr A, Furnary AP. J Heart Valve Dis; 2002 Nov; 11(6):844-50. PubMed ID: 12479287 [Abstract] [Full Text] [Related]
4. Twenty-year results of the Hancock II bioprosthesis. Borger MA, Ivanov J, Armstrong S, Christie-Hrybinsky D, Feindel CM, David TE. J Heart Valve Dis; 2006 Jan; 15(1):49-55; discussion 55-6. PubMed ID: 16480012 [Abstract] [Full Text] [Related]
9. Five-year follow up of the ATS mechanical heart valve. Emery RW, Krogh CC, Jones DJ, Nicoloff DM, Blake DP, Arom KV. J Heart Valve Dis; 2004 Mar; 13(2):231-8. PubMed ID: 15086262 [Abstract] [Full Text] [Related]
10. Twenty-year clinical experience with porcine bioprostheses. Fann JI, Miller DC, Moore KA, Mitchell RS, Oyer PE, Stinson EB, Robbins RC, Reitz BA, Shumway NE. Ann Thorac Surg; 1996 Nov; 62(5):1301-11; discussion 1311-2. PubMed ID: 8893561 [Abstract] [Full Text] [Related]
11. Eleven-year single-center experience with the ATS Open Pivot Bileaflet heart valve. Baykut D, Grize L, Schindler C, Keil AS, Bernet F, Zerkowski HR. Ann Thorac Surg; 2006 Sep; 82(3):847-52. PubMed ID: 16928496 [Abstract] [Full Text] [Related]
12. Fifteen years follow up with the St. Jude Medical Biocor porcine bioprosthesis. Mykén P, Bech-Hanssen O, Phipps B, Caidahl K. J Heart Valve Dis; 2000 May; 9(3):415-22. PubMed ID: 10888100 [Abstract] [Full Text] [Related]
13. Mechanical versus bioprosthetic valve replacement in middle-aged patients. Kulik A, Bédard P, Lam BK, Rubens FD, Hendry PJ, Masters RG, Mesana TG, Ruel M. Eur J Cardiothorac Surg; 2006 Sep; 30(3):485-91. PubMed ID: 16857373 [Abstract] [Full Text] [Related]
14. Up to nine-years' experience with the Allcarbon prosthetic heart valve. Ho TH, Van Nguyen P, Phan PK, Pham VN. J Heart Valve Dis; 2005 Jul; 14(4):512-7. PubMed ID: 16116878 [Abstract] [Full Text] [Related]
15. Long-term outcome after valve replacement with the omnicarbon prosthesis. di Summa M, Poletti G, Brero L, Centofanti P, La Torre M, Patanè F, Raggio JM, Sanchez FG, Maroñas JM, Torregrosa S, Valera FJ, Caffarena J. J Heart Valve Dis; 2002 Jul; 11(4):517-23. PubMed ID: 12150300 [Abstract] [Full Text] [Related]