These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
431 related items for PubMed ID: 10382162
1. Motion artifact control in body MR imaging. Barish MA, Jara H. Magn Reson Imaging Clin N Am; 1999 May; 7(2):289-301. PubMed ID: 10382162 [Abstract] [Full Text] [Related]
2. Fast spin-echo triple-echo Dixon: initial clinical experience with a novel pulse sequence for fat-suppressed T2-weighted abdominal MR imaging. Low RN, Ma J, Panchal N. J Magn Reson Imaging; 2009 Sep; 30(3):569-77. PubMed ID: 19711403 [Abstract] [Full Text] [Related]
3. Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? Alibek S, Adamietz B, Cavallaro A, Stemmer A, Anders K, Kramer M, Bautz W, Staatz G. Acad Radiol; 2008 Aug; 15(8):986-95. PubMed ID: 18620119 [Abstract] [Full Text] [Related]
4. Abdominal magnetic resonance imaging: optimization and artifact suppression. Mitchell DG. Top Magn Reson Imaging; 1992 Jun; 4(3):18-34. PubMed ID: 1605953 [Abstract] [Full Text] [Related]
5. Evaluation of focal liver lesions: fast-recovery fast spin echo T2-weighted MR imaging. Akin O, Schwartz LH, Welber A, Maier CF, Decorato DR, Panicek DM. Clin Imaging; 2006 Jun; 30(5):322-5. PubMed ID: 16919552 [Abstract] [Full Text] [Related]
6. [Breath-holding three-dimensional MR imaging: evaluation of phase reordering for motion artifact suppression]. Amanuma M, Kimura T, Takizawa O, Kozawa E, Enomoto K, Watabe T, Heshiki A. Nihon Igaku Hoshasen Gakkai Zasshi; 1995 Mar; 55(4):222-7. PubMed ID: 7746722 [Abstract] [Full Text] [Related]
7. Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques. Lee SS, Byun JH, Hong HS, Park SH, Won HJ, Shin YM, Lee MG. J Magn Reson Imaging; 2007 Aug; 26(2):323-30. PubMed ID: 17610287 [Abstract] [Full Text] [Related]
15. Cardiac MRI: comparison between single-shot fast spin echo and conventional spin echo sequences in the morphological evaluation of the ventricles. Erriquez D, Di Cesare E, Barile A, Gallucci M, Splendiani A, Masciocchi C. Radiol Med; 2002 Aug; 103(1-2):34-44. PubMed ID: 11859299 [Abstract] [Full Text] [Related]