These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
165 related items for PubMed ID: 10587695
1. Analytic and clinical evaluation of the Abbott AxSYM cardiac troponin I assay. ver Elst KM, Chapelle JP, Boland P, Demolder JS, Gorus FK. Am J Clin Pathol; 1999 Dec; 112(6):745-52. PubMed ID: 10587695 [Abstract] [Full Text] [Related]
2. Multicenter clinical and analytical evaluation of the AxSYM troponin-I immunoassay to assist in the diagnosis of myocardial infarction. Apple FS, Maturen AJ, Mullins RE, Painter PC, Pessin-Minsley MS, Webster RA, Spray Flores J, DeCresce R, Fink DJ, Buckley PM, Marsh J, Ricchiuti V, Christenson RH. Clin Chem; 1999 Feb; 45(2):206-12. PubMed ID: 9931042 [Abstract] [Full Text] [Related]
3. Improved identification of acute coronary syndromes with second generation cardiac troponin I assay: utility of 2-hour delta cTnI > or = +0.02 ng/mL. Fesmire FM, Fesmire CE. J Emerg Med; 2002 Feb; 22(2):147-52. PubMed ID: 11858918 [Abstract] [Full Text] [Related]
4. False-positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Elimination of this interference by using a polyclonal antisera against rheumatoid factors. Dasgupta A, Banerjee SK, Datta P. Am J Clin Pathol; 1999 Dec; 112(6):753-6. PubMed ID: 10587696 [Abstract] [Full Text] [Related]
5. Cardiac troponin-T immunoassay for diagnosis of acute myocardial infarction. Wu AH, Valdes R, Apple FS, Gornet T, Stone MA, Mayfield-Stokes S, Ingersoll-Stroubos AM, Wiler B. Clin Chem; 1994 Jun; 40(6):900-7. PubMed ID: 8087984 [Abstract] [Full Text] [Related]
6. Cardiac troponin I measurement with the ACCESS immunoassay system: analytical and clinical performance characteristics. Christenson RH, Apple FS, Morgan DL, Alonsozana GL, Mascotti K, Olson M, McCormack RT, Wians FH, Keffer JH, Duh SH. Clin Chem; 1998 Jan; 44(1):52-60. PubMed ID: 9550558 [Abstract] [Full Text] [Related]
7. Evaluation of the analytical performance of the advanced method for cardiac troponin I for the AxSYM platform: comparison with the old method and the Access system. Storti S, Prontera C, Parri MS, Iervasi A, Vittorini S, Emdin M, Zucchelli GC, Longombardo G, Migliorini P, Clerico A. Clin Chem Lab Med; 2006 Jan; 44(8):1022-9. PubMed ID: 16879072 [Abstract] [Full Text] [Related]
8. Analytical performance and clinical utility of a sensitive immunoassay for determination of human cardiac troponin I. Davies E, Gawad Y, Takahashi M, Shi Q, Lam P, Styba G, Lau A, Heeschen C, Usategui M, Jackowski G. Clin Biochem; 1997 Aug; 30(6):479-90. PubMed ID: 9316743 [Abstract] [Full Text] [Related]
9. False-positive troponin I measured with the Abbott AxSYM attributed to fibrin interference. Kazmierczak SC, Sekhon H, Richards C. Int J Cardiol; 2005 May 11; 101(1):27-31. PubMed ID: 15860379 [Abstract] [Full Text] [Related]
10. Development of monoclonal antibodies for an assay of cardiac troponin-I and preliminary results in suspected cases of myocardial infarction. Bodor GS, Porter S, Landt Y, Ladenson JH. Clin Chem; 1992 Nov 11; 38(11):2203-14. PubMed ID: 1424112 [Abstract] [Full Text] [Related]
11. Serum levels of cardiac troponin I and other marker proteins in patients with chronic renal failure. Nakai K, Nakai K, Nagane Y, Obara W, Sato M, Ohi K, Matsumoto N, Takanashi N, Itoh C. Clin Exp Nephrol; 2004 Mar 11; 8(1):43-7. PubMed ID: 15067515 [Abstract] [Full Text] [Related]
12. Comparison of Abbott AxSYM, Behring Opus Plus, DPC Immulite and Ortho-Clinical Diagnostics Vitros ECi for measurement of cardiac troponin I. Kao JT, Wong IL, Lee JY, Chen RC. Ann Clin Biochem; 2001 Mar 11; 38(Pt 2):140-6. PubMed ID: 11269755 [Abstract] [Full Text] [Related]
13. Effect of elevated concentration of alkaline phosphatase on cardiac troponin I assays. Dasgupta A, Chow L, Wells A, Datta P. J Clin Lab Anal; 2001 Mar 11; 15(4):175-7. PubMed ID: 11436198 [Abstract] [Full Text] [Related]
14. Evaluation of Stratus CS stat fluorimetric analyser for measurement of cardiac markers Troponin I (cTnI), creatine kinase MB (CK-MB), and myoglobin. Bénéteau-Burnat B, Baudin B, Vaubourdolle M. J Clin Lab Anal; 2001 Mar 11; 15(6):314-8. PubMed ID: 11793431 [Abstract] [Full Text] [Related]
15. Performance of the enhanced Abbott AxSYM cardiac troponin I reagent in patients with heterophilic antibodies. Yeo KT, Storm CA, Li Y, Jayne JE, Brough T, Quinn-Hall KS, Fitzmaurice TF. Clin Chim Acta; 2000 Feb 25; 292(1-2):13-23. PubMed ID: 10686273 [Abstract] [Full Text] [Related]
16. Evaluation of kryptor cardiac troponin I immunoassay. Lefèvre G, Graïne H, Bakkouch K, Garbarz E, Marlin G, Michel PL, Capeau J. Ann Clin Biochem; 2002 Mar 25; 39(Pt 2):145-7. PubMed ID: 11928763 [Abstract] [Full Text] [Related]
18. Clinical and analytical performance of automated immunochemiluminometric assays for determination of cardiac markers in serum. Panteghini M. J Biolumin Chemilumin; 1998 Mar 25; 13(5):307-9. PubMed ID: 9839196 [Abstract] [Full Text] [Related]
19. Impact of the troponin standard on the prevalence of acute myocardial infarction. Kontos MC, Fritz LM, Anderson FP, Tatum JL, Ornato JP, Jesse RL. Am Heart J; 2003 Sep 25; 146(3):446-52. PubMed ID: 12947361 [Abstract] [Full Text] [Related]
20. Comparison of cardiac troponin I versus T and creatine kinase MB after coronary artery bypass grafting in patients with and without perioperative myocardial infarction. Peivandi AA, Dahm M, Opfermann UT, Peetz D, Doerr F, Loos A, Oelert H. Herz; 2004 Nov 25; 29(7):658-64. PubMed ID: 15580320 [Abstract] [Full Text] [Related] Page: [Next] [New Search]