1. Arterial repair with synthetic patch by using titanium clips. Pikoulis E, Rhee P, Nishibe T, Burris D, Leppäniemi AK, Fishback N, Wherry DC, Rich NM. J Trauma; 2000 Feb; 48(2):292-5. PubMed ID: 10697089 [Abstract] [Full Text] [Related]
2. Arterial reconstruction with vascular clips is safe and quicker than sutured repair. Pikoulis E, Rhee P, Nishibe T, Leppäniemi AK, Fishback N, Hufnagel HV, Wherry DC, Rich NM. Cardiovasc Surg; 1998 Dec; 6(6):573-8. PubMed ID: 10395258 [Abstract] [Full Text] [Related]
3. Arterial and venous repair with vascular clips: comparison with suture closure. Leppäniemi A, Wherry D, Pikoulis E, Hufnagel H, Waasdorp C, Fishback N, Rich N. J Vasc Surg; 1997 Jul; 26(1):24-8. PubMed ID: 9240317 [Abstract] [Full Text] [Related]
4. Rapid arterial anastomosis with titanium clips. Pikoulis E, Burris D, Rhee P, Nishibe T, Leppäniemi A, Wherry D, Rich N. Am J Surg; 1998 Jun; 175(6):494-6. PubMed ID: 9645780 [Abstract] [Full Text] [Related]
5. Ureteral repair with titanium staples: comparison with suture closure. Leppäniemi AK, Wherry DC, Pikoulis E, Hufnagel HV, Fishback N, Rich NM. Urology; 1998 Apr; 51(4):553-7. PubMed ID: 9586606 [Abstract] [Full Text] [Related]
6. Common bile duct repair with titanium staples. Comparison with suture closure. Leppäniemi A, Wherry D, Pikoulis E, Hufnagel H, Waasdorp C, Fishback N, Rich N. Surg Endosc; 1997 Jul; 11(7):714-7. PubMed ID: 9214317 [Abstract] [Full Text] [Related]
7. Study comparing sutures and nonpenetrating titanium clips for arteriotomy closure after embolectomy. Pikoulis E, Koronarchis D, Filis K, Leppäniemi A, Papas S, Xiromeritis N, Papalambros E, Bastounis E. Surg Endosc; 2001 Jul; 15(7):726-8. PubMed ID: 11591977 [Abstract] [Full Text] [Related]
8. Growing cava vein anastomosis: comparison of cross-clamping and suture times using VCS metallic clips, interrupted nonabsorbable, or continuous absorbable suturing techniques. Calles-Vázquez MC, Abellán Rubio E, Ayala VC, Usón Gargallo J, Sánchez Margallo FM. Ann Vasc Surg; 2013 Oct; 27(7):947-53. PubMed ID: 23993110 [Abstract] [Full Text] [Related]
9. Vein patch angioplasty with non-penetrating titanium clips. Comparison to standard suture technique. Pikoulis E, Rhee P, Nishibe T, Koronarchis D, Leppäniemi A, Karavokyros I, Burris D, Bakoyiannis C, Fishback N, Wherry D, Rich N. Acta Chir Belg; 2009 Oct; 109(6):756-9. PubMed ID: 20184062 [Abstract] [Full Text] [Related]
10. Vascular closure stapler clip anastomosis decreases aortic cross-clamping time compared to interrupted nonabsorbable and running absorbable sutures in growing pigs. Calles-Vázquez MC, Viguera FJ, Crisóstomo V, Usón-Gargallo J. Ann Vasc Surg; 2006 Jan; 20(1):35-41. PubMed ID: 16378146 [Abstract] [Full Text] [Related]
11. Anastomoses in the common femoral artery, vascular clips or sutures? A feasibility study. Donker JM, Tijnagel MJ, van Zeeland ML, Veen EJ, van der Laan L. Ann Vasc Surg; 2013 Feb; 27(2):194-8. PubMed ID: 22840340 [Abstract] [Full Text] [Related]
12. Comparison of titanium vascular closure staples with suture repair of the thoracic aorta in swine. Deb S, Martin B, Sun L, Burris D, Wherry D, Pikoulis E, Rhee P. Chest; 2000 Dec; 118(6):1762-8. PubMed ID: 11115470 [Abstract] [Full Text] [Related]
13. Vascular closure stapler clips versus polypropylene sutures in end-to-end anastomoses of growing arteries and veins. Calles-Vázquez MC, Usón JM, Viguera FJ, Sun F, Paz JI, Usón-Gargallo J. Ann Vasc Surg; 2005 May; 19(3):320-7. PubMed ID: 15818456 [Abstract] [Full Text] [Related]
14. Angiographic, ultrasonographic, and macroscopic assessment of aortic growth after VCS clips, interrupted polypropylene, or running polyglycolic acid anastomosis. Calles-Vázquez MC, Crisóstomo V, Sun F, Usón-Gargallo J. J Pediatr Surg; 2007 Oct; 42(10):1695-702. PubMed ID: 17923198 [Abstract] [Full Text] [Related]
15. Five years' world experience with nonpenetrating clips for vascular anastomoses. Zeebregts CJ, Kirsch WM, van den Dungen JJ, Zhu YH, van Schilfgaarde R. Am J Surg; 2004 Jun; 187(6):751-60. PubMed ID: 15191871 [Abstract] [Full Text] [Related]
16. Heterotopic renal transplantation in piglets using vascular closure stapler metallic clips or conventional suturing techniques: comparison of vessel growth and macroscopical study. Calles-Vázquez MC, Rubio EA, Ayala VC, Gargallo JU, Margallo FM. J Pediatr Surg; 2012 Jul; 47(7):1390-8. PubMed ID: 22813802 [Abstract] [Full Text] [Related]
17. Clinical application of vascular closure staple clips for blood access surgery. Haruguchi H, Nakagawa Y, Uchida Y, Sageshima J, Fuchinoue S, Agishi T. ASAIO J; 1998 Jul; 44(5):M562-4. PubMed ID: 9804495 [Abstract] [Full Text] [Related]
18. Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage. Ito K, Aoyama T, Horiuchi T, Hongo K. J Neurosurg Spine; 2015 Dec; 23(6):812-9. PubMed ID: 26315957 [Abstract] [Full Text] [Related]
19. [Titanium metallic clips: easier and faster than conventional suturing for heterotopic renal autotransplant in growing pigs]. Calles Vázquez MC, Abellan Rubio E, Crisóstomo Ayala V, Martín Cancho MF, Sánchez Margallo FM, Usón Gargallo J. Actas Urol Esp; 2009 Jan; 33(1):76-82. PubMed ID: 19462729 [Abstract] [Full Text] [Related]