These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


145 related items for PubMed ID: 10735458

  • 1.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 2.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 3.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 4. Comparison of two strip test methods of whole blood glucose measurement in the neonatal period.
    Papp M, Sharief N.
    Acta Paediatr; 2001 Sep; 90(9):1042-6. PubMed ID: 11683193
    [Abstract] [Full Text] [Related]

  • 5. The effect of the haematocrit value on the determination of glucose levels by reagent-strip methods.
    Barreau PB, Buttery JE.
    Med J Aust; 1987 Sep 21; 147(6):286-8. PubMed ID: 3626945
    [Abstract] [Full Text] [Related]

  • 6. The effect of haematocrit on reagent strip tests for glucose.
    Wiener K.
    Diabet Med; 1991 Sep 21; 8(2):172-5. PubMed ID: 1827405
    [Abstract] [Full Text] [Related]

  • 7. Calibration of glucose oxidase-based test strips for capillary blood measurement with oxygen saturated venous blood samples.
    Cheng WJ, Lin CW, Wu TG, Su CS, Hsieh MS.
    Clin Chim Acta; 2013 Jan 16; 415():152-7. PubMed ID: 23089075
    [Abstract] [Full Text] [Related]

  • 8. Relationships of glucose concentrations in capillary whole blood, venous whole blood and venous plasma.
    Kuwa K, Nakayama T, Hoshino T, Tominaga M.
    Clin Chim Acta; 2001 May 16; 307(1-2):187-92. PubMed ID: 11369356
    [Abstract] [Full Text] [Related]

  • 9. Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care/hospital/ambulatory patients in the United States and Canada.
    Kost GJ, Vu HT, Lee JH, Bourgeois P, Kiechle FL, Martin C, Miller SS, Okorodudu AO, Podczasy JJ, Webster R, Whitlow KJ.
    Crit Care Med; 1998 Mar 16; 26(3):581-90. PubMed ID: 9504590
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12. Assessing the Accuracy of Continuous Glucose Monitoring (CGM) Calibrated With Capillary Values Using Capillary or Venous Glucose Levels as a Reference.
    Andelin M, Kropff J, Matuleviciene V, Joseph JI, Attvall S, Theodorsson E, Hirsch IB, Imberg H, Dahlqvist S, Klonoff D, Haraldsson B, DeVries JH, Lind M.
    J Diabetes Sci Technol; 2016 Jul 16; 10(4):876-84. PubMed ID: 26810924
    [Abstract] [Full Text] [Related]

  • 13. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).
    Dimeski G, Jones BW, Tilley V, Greenslade MN, Russell AW.
    Ann Clin Biochem; 2010 Jul 16; 47(Pt 4):358-65. PubMed ID: 20592335
    [Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. Near-patient testing of blood glucose using the Bayer Rapidlab 860 analyser in a regional neonatal unit.
    Peet AC, Kennedy DM, Hocking MD, Ewer AK.
    Ann Clin Biochem; 2002 Sep 16; 39(Pt 5):502-8. PubMed ID: 12227857
    [Abstract] [Full Text] [Related]

  • 16. The effect of variations in haematocrit, mean cell volume and red blood cell count on reagent strip tests for glucose.
    Kilpatrick ES, Rumley AG, Myint H, Dominiczak MH, Small M.
    Ann Clin Biochem; 1993 Sep 16; 30 ( Pt 5)():485-7. PubMed ID: 8250502
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18. Correlation Between Capillary and Venous Blood Glucose in the Lactose Tolerance Test.
    Domínguez Jiménez JL, Fernández Suárez A.
    Dig Dis Sci; 2016 Jan 16; 61(1):208-14. PubMed ID: 26320083
    [Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 8.