These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
185 related items for PubMed ID: 10828192
1. High-resolution diffusion imaging using a radial turbo-spin-echo sequence: implementation, eddy current compensation, and self-navigation. Seifert MH, Jakob PM, Jellus V, Haase A, Hillenbrand C. J Magn Reson; 2000 Jun; 144(2):243-54. PubMed ID: 10828192 [Abstract] [Full Text] [Related]
2. Double-spin-echo diffusion weighting with a modified eddy current adjustment. Finsterbusch J. Magn Reson Imaging; 2010 Apr; 28(3):434-40. PubMed ID: 20071120 [Abstract] [Full Text] [Related]
3. Diffusion-weighted imaging in patients with acute brain ischemia at 3 T: current possibilities and future perspectives comparing conventional echoplanar diffusion-weighted imaging and fast spin echo diffusion-weighted imaging sequences using BLADE (PROPELLER). Fries P, Runge VM, Kirchin MA, Stemmer A, Naul LG, Wiliams KD, Reith W, Bücker A, Schneider G. Invest Radiol; 2009 Jun; 44(6):351-9. PubMed ID: 19363447 [Abstract] [Full Text] [Related]
4. Diffusion-weighted MR of the brain: methodology and clinical application. Mascalchi M, Filippi M, Floris R, Fonda C, Gasparotti R, Villari N. Radiol Med; 2005 Mar; 109(3):155-97. PubMed ID: 15775887 [Abstract] [Full Text] [Related]
5. Improvement of the diffusion-weighted images acquired with radial trajectories using projection data regeneration. Han Y, Hwang J, Chung JY, Yun S, Park H. J Magn Reson Imaging; 2007 Sep; 26(3):799-804. PubMed ID: 17685419 [Abstract] [Full Text] [Related]
6. Stimulated echo induced misestimates on diffusion tensor indices and its remedy. Chuang TC, Wu MT, Huang TY, Lin YR, Tsai SY, Chang HC, Chung HW. J Magn Reson Imaging; 2010 Jun; 31(6):1522-9. PubMed ID: 20512910 [Abstract] [Full Text] [Related]
7. An optimized pulse sequence for isotropically weighted diffusion imaging. Cercignani M, Horsfield MA. J Magn Reson; 1999 Sep; 140(1):58-68. PubMed ID: 10479549 [Abstract] [Full Text] [Related]
8. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study. Hussain SM, De Becker J, Hop WC, Dwarkasing S, Wielopolski PA. J Magn Reson Imaging; 2005 Mar; 21(3):219-29. PubMed ID: 15723376 [Abstract] [Full Text] [Related]
9. Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Reese TG, Heid O, Weisskoff RM, Wedeen VJ. Magn Reson Med; 2003 Jan; 49(1):177-82. PubMed ID: 12509835 [Abstract] [Full Text] [Related]
10. Mapping eddy current induced fields for the correction of diffusion-weighted echo planar images. Horsfield MA. Magn Reson Imaging; 1999 Nov; 17(9):1335-45. PubMed ID: 10576719 [Abstract] [Full Text] [Related]
11. A field-monitoring-based approach for correcting eddy-current-induced artifacts of up to the 2nd spatial order in human-connectome-project-style multiband diffusion MRI experiment at 7T: A pilot study. Ma R, Akçakaya M, Moeller S, Auerbach E, Uğurbil K, Van de Moortele PF. Neuroimage; 2020 Aug 01; 216():116861. PubMed ID: 32305565 [Abstract] [Full Text] [Related]
12. Reconstruction as a source of artifact in non-gated single-shot diffusion-weighted EPI. Robson MD, Porter DA. Magn Reson Imaging; 2005 Nov 01; 23(9):899-905. PubMed ID: 16310105 [Abstract] [Full Text] [Related]
13. Online motion correction for diffusion-weighted segmented-EPI and FLASH imaging. Weih KS, Driesel W, von Mengershausen M, Norris DG. MAGMA; 2004 May 01; 16(6):277-83. PubMed ID: 15052418 [Abstract] [Full Text] [Related]
14. Characterization and correction of diffusion gradient-induced eddy currents in second-order motion-compensated echo-planar and spiral cardiac DTI. van Gorkum RJH, Guenthner C, Koethe A, Stoeck CT, Kozerke S. Magn Reson Med; 2022 Dec 01; 88(6):2378-2394. PubMed ID: 35916545 [Abstract] [Full Text] [Related]
15. A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI. Andersson JL, Skare S. Neuroimage; 2002 May 01; 16(1):177-99. PubMed ID: 11969328 [Abstract] [Full Text] [Related]
16. Optimization of diffusion-weighted single-refocused spin-echo EPI by reducing eddy-current artifacts and shortening the echo time. Shrestha M, Hok P, Nöth U, Lienerth B, Deichmann R. MAGMA; 2018 Oct 01; 31(5):585-597. PubMed ID: 29603048 [Abstract] [Full Text] [Related]
17. Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display. Takahara T, Imai Y, Yamashita T, Yasuda S, Nasu S, Van Cauteren M. Radiat Med; 2004 Oct 01; 22(4):275-82. PubMed ID: 15468951 [Abstract] [Full Text] [Related]
18. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Andersson JL, Skare S, Ashburner J. Neuroimage; 2003 Oct 01; 20(2):870-88. PubMed ID: 14568458 [Abstract] [Full Text] [Related]
19. MRI of the female pelvis at 3T compared to 1.5T: evaluation on high-resolution T2-weighted and HASTE images. Kataoka M, Kido A, Koyama T, Isoda H, Umeoka S, Tamai K, Nakamoto Y, Maetani Y, Morisawa N, Saga T, Togashi K. J Magn Reson Imaging; 2007 Mar 01; 25(3):527-34. PubMed ID: 17326081 [Abstract] [Full Text] [Related]