These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


131 related items for PubMed ID: 10855635

  • 1. Imaging pulmonary emboli and deep venous thrombi with 99mTc-bitistatin, a platelet-binding polypeptide from viper venom.
    Knight LC, Baidoo KE, Romano JE, Gabriel JL, Maurer AH.
    J Nucl Med; 2000 Jun; 41(6):1056-64. PubMed ID: 10855635
    [Abstract] [Full Text] [Related]

  • 2. Comparison of iodine-123-disintegrins for imaging thrombi and emboli in a canine model.
    Knight LC, Maurer AH, Romano JE.
    J Nucl Med; 1996 Mar; 37(3):476-82. PubMed ID: 8772651
    [Abstract] [Full Text] [Related]

  • 3. In vitro platelet binding compared with in vivo thrombus imaging using alpha(IIb)beta3-targeted radioligands.
    Knight LC, Romano JE, Maurer AH.
    Thromb Haemost; 1998 Nov; 80(5):845-51. PubMed ID: 9843182
    [Abstract] [Full Text] [Related]

  • 4. Imaging vascular thrombosis with 99mTc-labeled fibrin alpha-chain peptide.
    Thakur ML, Pallela VR, Consigny PM, Rao PS, Vessileva-Belnikolovska D, Shi R.
    J Nucl Med; 2000 Jan; 41(1):161-8. PubMed ID: 10647619
    [Abstract] [Full Text] [Related]

  • 5. Use of radiolabeled peptides to image deep venous thrombosis and pulmonary embolism.
    Muto P, Lastoria S.
    J Nucl Med; 2000 Jun; 41(6):1065-6. PubMed ID: 10855636
    [No Abstract] [Full Text] [Related]

  • 6. Detection of thromboembolism with ⁹⁹mTc-labeled F(ab)₂ fragment of anti-glycoprotein IIIa chimeric monoclonal antibody in beagle canines.
    Ji S, Fang W, Dong N, He Z, Ruan C.
    Thromb Res; 2012 Nov; 130(5):703-8. PubMed ID: 22967949
    [Abstract] [Full Text] [Related]

  • 7. [Imaging of thromboembolism by scintigraphy with the 99m-technetium-labelled synthetic peptide P280].
    Lastoria S, Vergara E, Varrella P, Muto P, Acampa W, Caracò C, Salvatore M.
    Radiol Med; 1995 Dec; 90(6):812-9. PubMed ID: 8685469
    [Abstract] [Full Text] [Related]

  • 8. Pre-clinical evaluation of technetium-99m platelet receptor-binding peptide.
    Lister-James J, Vallabhajosula S, Moyer BR, Pearson DA, McBride BJ, De Rosch MA, Bush LR, Machac J, Dean RT.
    J Nucl Med; 1997 Jan; 38(1):105-11. PubMed ID: 8998163
    [Abstract] [Full Text] [Related]

  • 9. Design and synthesis of a short-chain bitistatin analogue for imaging thrombi and emboli.
    Baidoo KE, Knight LC, Lin KS, Gabriel JL, Romano JE.
    Bioconjug Chem; 2004 Jan; 15(5):1068-75. PubMed ID: 15366961
    [Abstract] [Full Text] [Related]

  • 10.
    Leung K.
    ; 2004 Jan. PubMed ID: 20641217
    [Abstract] [Full Text] [Related]

  • 11. Biological evaluation of thrombus imaging agents utilizing water soluble phosphines and tricine as coligands when used to label a hydrazinonicotinamide-modified cyclic glycoprotein IIb/IIIa receptor antagonist with 99mTc.
    Barrett JA, Crocker AC, Damphousse DJ, Heminway SJ, Liu S, Edwards DS, Lazewatsky JL, Kagan M, Mazaika TJ, Carroll TR.
    Bioconjug Chem; 1997 Jan; 8(2):155-60. PubMed ID: 9095355
    [Abstract] [Full Text] [Related]

  • 12. Functional expression of bitistatin, a disintegrin with potential use in molecular imaging of thromboembolic disease.
    Knight LC, Romano JE.
    Protein Expr Purif; 2005 Feb; 39(2):307-19. PubMed ID: 15642483
    [Abstract] [Full Text] [Related]

  • 13. Biological evaluation of 99mTc-labeled cyclic glycoprotein IIb/IIIa receptor antagonists in the canine arteriovenous shunt and deep vein thrombosis models: effects of chelators on biological properties of [99mTc]chelator-peptide conjugates.
    Barrett JA, Damphousse DJ, Heminway SJ, Liu S, Edwards DS, Looby RJ, Carroll TR.
    Bioconjug Chem; 1996 Feb; 7(2):203-8. PubMed ID: 8983342
    [Abstract] [Full Text] [Related]

  • 14. Radiation Dosimetry of the Fibrin-Binding Probe ⁶⁴Cu-FBP8 and Its Feasibility for PET Imaging of Deep Vein Thrombosis and Pulmonary Embolism in Rats.
    Blasi F, Oliveira BL, Rietz TA, Rotile NJ, Day H, Naha PC, Cormode DP, Izquierdo-Garcia D, Catana C, Caravan P.
    J Nucl Med; 2015 Jul; 56(7):1088-93. PubMed ID: 25977464
    [Abstract] [Full Text] [Related]

  • 15. Radiolabeled peptides in the detection of deep venous thrombosis.
    Taillefer R.
    Semin Nucl Med; 2001 Apr; 31(2):102-23. PubMed ID: 11330782
    [Abstract] [Full Text] [Related]

  • 16. Thrombus imaging with a technetium-99m-labeled activated platelet receptor-binding peptide.
    Lister-James J, Knight LC, Maurer AH, Bush LR, Moyer BR, Dean RT.
    J Nucl Med; 1996 May; 37(5):775-81. PubMed ID: 8965144
    [Abstract] [Full Text] [Related]

  • 17. Evaluation of 99mTc-labeled cyclic RGD peptide with a PEG4 linker for thrombosis imaging: comparison with DMP444.
    Fang W, He J, Kim YS, Zhou Y, Liu S.
    Bioconjug Chem; 2011 Aug 17; 22(8):1715-22. PubMed ID: 21780818
    [Abstract] [Full Text] [Related]

  • 18. Imaging thromboembolism with fibrin-avid 99mTc-peptide: evaluation in swine.
    Aruva MR, Daviau J, Sharma SS, Thakur ML.
    J Nucl Med; 2006 Jan 17; 47(1):155-62. PubMed ID: 16391200
    [Abstract] [Full Text] [Related]

  • 19. Acute thromboscintigraphy with (99m)Tc-apcitide: results of the phase 3 multicenter clinical trial comparing 99mTc-apcitide scintigraphy with contrast venography for imaging acute DVT. Multicenter Trial Investigators.
    Taillefer R, Edell S, Innes G, Lister-James J.
    J Nucl Med; 2000 Jul 17; 41(7):1214-23. PubMed ID: 10914912
    [Abstract] [Full Text] [Related]

  • 20. Detecting deep venous thrombosis with technetium-99m-labeled synthetic peptide P280.
    Muto P, Lastoria S, Varrella P, Vergara E, Salvatore M, Morgano G, Lister-James J, Bernardy JD, Dean RT, Wencker D.
    J Nucl Med; 1995 Aug 17; 36(8):1384-91. PubMed ID: 7629582
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.