These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


429 related items for PubMed ID: 10864986

  • 1. Evaluation of polyethylene terephthalate for ABO and Rh typing and alloantibody screening.
    Anderson DR, Wiseman J, MacLeod J, Burton E, Zayed E.
    Transfusion; 2000 Jun; 40(6):669-72. PubMed ID: 10864986
    [Abstract] [Full Text] [Related]

  • 2. Evaluation of the gel system for ABO grouping and D typing.
    Langston MM, Procter JL, Cipolone KM, Stroncek DF.
    Transfusion; 1999 Mar; 39(3):300-5. PubMed ID: 10204594
    [Abstract] [Full Text] [Related]

  • 3. ABO and D typing and alloantibody screening in marrow samples: relevance to intraosseous blood transfusion.
    Bäckman S, Ångerman-Haasmaa S, Jousi M, Siitonen S, Salmela K.
    Transfusion; 2018 Jun; 58(6):1372-1376. PubMed ID: 29492974
    [Abstract] [Full Text] [Related]

  • 4. Evaluation of an automated microplate technique in the Galileo system for ABO and Rh(D) blood grouping.
    Xu W, Wan F, Lou Y, Jin J, Mao W.
    Clin Lab; 2014 Jun; 60(2):241-4. PubMed ID: 24660536
    [Abstract] [Full Text] [Related]

  • 5. Comparison of a gel microcolumn assay with the conventional tube test for red blood cell alloantibody titration.
    Finck R, Lui-Deguzman C, Teng SM, Davis R, Yuan S.
    Transfusion; 2013 Apr; 53(4):811-5. PubMed ID: 22804101
    [Abstract] [Full Text] [Related]

  • 6. Evaluation of Erytra® fully automated analyser for Routine Use in Transfusion Laboratory.
    Chang C, Brown M, Davies L, Pointon L, Brown R, Barker D.
    Transfus Med; 2014 Feb; 24(1):33-8. PubMed ID: 24188135
    [Abstract] [Full Text] [Related]

  • 7. Red Cell Alloimmunization in Repeatedly Transfused Sudanese Patients with leukemia in Northern Sudan.
    Abdalkream Jawish TA, Hessen HM, Alshafeea MA, Mohamedahmed KA, Ahmed EA, Modawe GA, Ibrahim IK.
    Asian Pac J Cancer Prev; 2023 Jan 01; 24(1):21-24. PubMed ID: 36708548
    [Abstract] [Full Text] [Related]

  • 8. The effects of diaspirin-crosslinked hemoglobin on the assessment of immunohematology profiles.
    Reppucci AJ, Mattia-Goldberg C, Przybelski RJ, Kuczerepa PR, Balma DL.
    Transfusion; 1997 Jan 01; 37(11-12):1143-8. PubMed ID: 9426637
    [Abstract] [Full Text] [Related]

  • 9. Multicentre evaluation of Erytra Eflexis®, a benchtop fully automated analyser with a compact design for routine use in blood transfusion laboratory.
    Elliott C, Carrascosa T, Souchet JL, Smith D, Malaxetxebarria I, You J, Bendahan M, Barnes S, Lisle F, Whitehouse N.
    Transfus Med; 2019 Dec 01; 29(6):401-407. PubMed ID: 31321832
    [Abstract] [Full Text] [Related]

  • 10. The suitability of hemolyzed specimens for compatibility testing using automated technology.
    Laga A, Cheves T, Maroto S, Coutts M, Sweeney J.
    Transfusion; 2008 Aug 01; 48(8):1713-20. PubMed ID: 18482191
    [Abstract] [Full Text] [Related]

  • 11. Evaluation of two automated instruments for pre-transfusion testing: AutoVue Innova and Techno TwinStation.
    Shin SY, Kwon KC, Koo SH, Park JW, Ko CS, Song JH, Sung JY.
    Korean J Lab Med; 2008 Jun 01; 28(3):214-20. PubMed ID: 18594174
    [Abstract] [Full Text] [Related]

  • 12. Economic and workflow analysis of a blood bank automated system.
    Shin KH, Kim HH, Chang CL, Lee EY.
    Ann Lab Med; 2013 Jul 01; 33(4):268-73. PubMed ID: 23826563
    [Abstract] [Full Text] [Related]

  • 13. Evaluation of a lateral flow-based technology card for blood typing using a simplified protocol in a model of extreme blood sampling conditions.
    Clavier B, Pouget T, Sailliol A.
    Transfusion; 2018 Feb 01; 58(2):313-316. PubMed ID: 29193130
    [Abstract] [Full Text] [Related]

  • 14. A new plastic collection tube made of polyethylene terephtalate is suitable for monitoring traditional anticoagulant therapy (oral anticoagulant, unfractionated heparin, and low molecular weight heparin).
    Toulon P, Ajzenberg N, Smahi M, Guillin MC.
    Thromb Res; 2007 Feb 01; 119(2):135-43. PubMed ID: 16426667
    [Abstract] [Full Text] [Related]

  • 15. [Electronic data processing-assisted serial automation of current methods in blood group serology].
    Brinkhues O, Giers G, Hanfland P.
    Beitr Infusionsther; 1992 Feb 01; 30():474-7. PubMed ID: 1284764
    [Abstract] [Full Text] [Related]

  • 16. Evaluation of a new generation of plastic evacuated blood-collection tubes in clinical chemistry, therapeutic drug monitoring, hormone and trace metal analysis.
    Boeynaems JM, De Leener A, Dessars B, Villa-Lobos HR, Aubry JC, Cotton F, Thiry P.
    Clin Chem Lab Med; 2004 Jan 01; 42(1):67-71. PubMed ID: 15061383
    [Abstract] [Full Text] [Related]

  • 17. A possible case of a haemolytic transfusion reaction caused by anti-Le(a) antibody.
    Duncan V, Pham HP, Williams LA.
    Blood Transfus; 2015 Jul 01; 13(3):535-6. PubMed ID: 26057494
    [No Abstract] [Full Text] [Related]

  • 18. Retrospective analysis of forward and reverse ABO typing discrepancies among patients and blood donors in a tertiary care hospital.
    Makroo RN, Kakkar B, Agrawal S, Chowdhry M, Prakash B, Karna P.
    Transfus Med; 2019 Apr 01; 29(2):103-109. PubMed ID: 29327382
    [Abstract] [Full Text] [Related]

  • 19. Automated blood grouping by gel technology.
    Parker PI, Scott Y, McArdle B, Wallis JP.
    Br J Biomed Sci; 1995 Dec 01; 52(4):266-70. PubMed ID: 8555780
    [Abstract] [Full Text] [Related]

  • 20. Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes.
    Dasgupta A, Blackwell W, Bard D.
    Ther Drug Monit; 1996 Jun 01; 18(3):306-9. PubMed ID: 8738774
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 22.