These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


717 related items for PubMed ID: 10888100

  • 1. Fifteen years follow up with the St. Jude Medical Biocor porcine bioprosthesis.
    Mykén P, Bech-Hanssen O, Phipps B, Caidahl K.
    J Heart Valve Dis; 2000 May; 9(3):415-22. PubMed ID: 10888100
    [Abstract] [Full Text] [Related]

  • 2. Seventeen-year experience with the St. Jude medical biocor porcine bioprosthesis.
    Mykén PS.
    J Heart Valve Dis; 2005 Jul; 14(4):486-92. PubMed ID: 16116875
    [Abstract] [Full Text] [Related]

  • 3. Medtronic mosaic porcine bioprosthesis: investigational center experience to six years.
    Jamieson WR, Fradet GJ, MacNab JS, Burr LH, Stanford EA, Janusz MT, Abel JG, Germann E, Cheung A.
    J Heart Valve Dis; 2005 Jan; 14(1):54-63. PubMed ID: 15700437
    [Abstract] [Full Text] [Related]

  • 4. Eighteen-year follow up after Hancock II bioprosthesis insertion.
    Legarra JJ, Llorens R, Catalan M, Segura I, Trenor AM, de Buruaga JS, Rabago G, Sarralde A.
    J Heart Valve Dis; 1999 Jan; 8(1):16-24. PubMed ID: 10096477
    [Abstract] [Full Text] [Related]

  • 5. Long-term follow up of patients undergoing reoperative surgery with aortic or mitral valve replacement using a St. Jude Medical prosthesis.
    Emery RW, Krogh CC, McAdams S, Emery AM, Holter AR.
    J Heart Valve Dis; 2010 Jul; 19(4):473-84. PubMed ID: 20845896
    [Abstract] [Full Text] [Related]

  • 6. Carpentier-Edwards porcine bioprostheses: clinical performance assessed by actual analysis.
    Jamieson WR, Miyagishima RT, Burr LH, Lichtenstein SV, Fradet GJ, Janusz MT.
    J Heart Valve Dis; 2000 Jul; 9(4):530-5. PubMed ID: 10947046
    [Abstract] [Full Text] [Related]

  • 7. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
    Emery RW, Krogh CC, Arom KV, Emery AM, Benyo-Albrecht K, Joyce LD, Nicoloff DM.
    Ann Thorac Surg; 2005 Mar; 79(3):776-82; discussion 782-3. PubMed ID: 15734375
    [Abstract] [Full Text] [Related]

  • 8. Twenty-year results of the Hancock II bioprosthesis.
    Borger MA, Ivanov J, Armstrong S, Christie-Hrybinsky D, Feindel CM, David TE.
    J Heart Valve Dis; 2006 Jan; 15(1):49-55; discussion 55-6. PubMed ID: 16480012
    [Abstract] [Full Text] [Related]

  • 9. Twenty-year clinical experience with porcine bioprostheses.
    Fann JI, Miller DC, Moore KA, Mitchell RS, Oyer PE, Stinson EB, Robbins RC, Reitz BA, Shumway NE.
    Ann Thorac Surg; 1996 Nov; 62(5):1301-11; discussion 1311-2. PubMed ID: 8893561
    [Abstract] [Full Text] [Related]

  • 10. Porcine versus pericardial bioprostheses: eleven-year follow up of a prospective randomized trial.
    Chaudhry MA, Raco L, Muriithi EW, Bernacca GM, Tolland MM, Wheatley DJ.
    J Heart Valve Dis; 2000 May; 9(3):429-37; discussion 437-8. PubMed ID: 10888102
    [Abstract] [Full Text] [Related]

  • 11. CarboMedics mechanical prosthesis: performance at eight years.
    Jamieson WR, Fradet GJ, Miyagishima RT, Henderson C, Brownlee RT, Zhang J, Germann E.
    J Heart Valve Dis; 2000 Sep; 9(5):678-87. PubMed ID: 11041184
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. Clinical evaluation of the carbomedics prosthesis: experience at providence health system in Portland.
    Minakata K, Wu Y, Zerr KJ, Grunkemeier GL, Handy JR, Ahmad A, Starr A, Furnary AP.
    J Heart Valve Dis; 2002 Nov; 11(6):844-50. PubMed ID: 12479287
    [Abstract] [Full Text] [Related]

  • 15. Early clinical experience with the On-X prosthetic heart valve.
    Laczkovics A, Heidt M, Oelert H, Laufer G, Greve H, Pomar JL, Mohr FW, Haverich A, Birnbaum D, Regensburger D, Palatianos G, Wolner E.
    J Heart Valve Dis; 2001 Jan; 10(1):94-9. PubMed ID: 11206775
    [Abstract] [Full Text] [Related]

  • 16. Aspire porcine bioprosthesis: ten years' experience.
    Hadjinikolaou L, Boehm MC, Ganner C, Kendall SW, Rosin MD, Goldsmith IR, Spyt TJ.
    J Heart Valve Dis; 2005 Jan; 14(1):47-53. PubMed ID: 15700436
    [Abstract] [Full Text] [Related]

  • 17. Experience with low-dose aspirin as thromboprophylaxis for the Tissuemed porcine aortic bioprosthesis: a survey of five years' experience.
    Goldsmith I, Lip GY, Mukundan S, Rosin MD.
    J Heart Valve Dis; 1998 Sep; 7(5):574-9. PubMed ID: 9793859
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Long-term follow up of the Biocor porcine bioprosthesis in the mitral position.
    Pomerantzeff PM, Brandão CM, Albuquerque JM, Stolf NA, Grinberg M, Oliveira SA.
    J Heart Valve Dis; 2006 Nov; 15(6):763-6; discussion 766-7. PubMed ID: 17152783
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 36.