These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
247 related items for PubMed ID: 10921936
1. Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma. Erice A, Brambilla D, Bremer J, Jackson JB, Kokka R, Yen-Lieberman B, Coombs RW. J Clin Microbiol; 2000 Aug; 38(8):2837-45. PubMed ID: 10921936 [Abstract] [Full Text] [Related]
2. Clinical comparison of an enhanced-sensitivity branched-DNA assay and reverse transcription-PCR for quantitation of human immunodeficiency virus type 1 RNA in plasma. Nolte FS, Boysza J, Thurmond C, Clark WS, Lennox JL. J Clin Microbiol; 1998 Mar; 36(3):716-20. PubMed ID: 9508301 [Abstract] [Full Text] [Related]
3. Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma. Murphy DG, Côté L, Fauvel M, René P, Vincelette J. J Clin Microbiol; 2000 Nov; 38(11):4034-41. PubMed ID: 11060065 [Abstract] [Full Text] [Related]
4. Comparative evaluation of the QUANTIPLEX HIV-1 RNA 2.0 and 3.0 (bDNA) assays and the AMPLICOR HIV-1 MONITOR v1.5 test for the quantitation of human immunodeficiency virus type 1 RNA in plasma. Anastassopoulou CG, Touloumi G, Katsoulidou A, Hatzitheodorou H, Pappa M, Paraskevis D, Lazanas M, Gargalianos P, Hatzakis A. J Virol Methods; 2001 Jan; 91(1):67-74. PubMed ID: 11164487 [Abstract] [Full Text] [Related]
5. Quantitative and cost comparison of ultrasensitive human immunodeficiency virus type 1 RNA viral load assays: Bayer bDNA quantiplex versions 3.0 and 2.0 and Roche PCR Amplicor monitor version 1.5. Elbeik T, Charlebois E, Nassos P, Kahn J, Hecht FM, Yajko D, Ng V, Hadley K. J Clin Microbiol; 2000 Mar; 38(3):1113-20. PubMed ID: 10699005 [Abstract] [Full Text] [Related]
6. Comparison of the Quantiplex version 3.0 assay and a sensitized Amplicor monitor assay for measurement of human immunodeficiency virus type 1 RNA levels in plasma samples. Highbarger HC, Alvord WG, Jiang MK, Shah AS, Metcalf JA, Lane HC, Dewar RL. J Clin Microbiol; 1999 Nov; 37(11):3612-4. PubMed ID: 10523562 [Abstract] [Full Text] [Related]
7. Comparative evaluation of three assays for the quantitation of human immunodeficiency virus type 1 RNA in plasma. Coste J, Montes B, Reynes J, Peeters M, Segarra C, Vendrell JP, Delaporte E, Segondy M. J Med Virol; 1996 Dec; 50(4):293-302. PubMed ID: 8950685 [Abstract] [Full Text] [Related]
8. Comparative evaluation of the Cobas Amplicor HIV-1 Monitor Ultrasensitive Test, the new Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test and the Versant HIV RNA 3.0 assays for quantitation of HIV-1 RNA in plasma samples. Berger A, Scherzed L, Stürmer M, Preiser W, Doerr HW, Rabenau HF. J Clin Virol; 2005 May; 33(1):43-51. PubMed ID: 15797364 [Abstract] [Full Text] [Related]
9. Comparison of three commercial assays for the quantification of HIV-1 RNA in plasma from individuals infected with different HIV-1 subtypes. Chew CB, Herring BL, Zheng F, Browne C, Saksena NK, Cunningham AL, Dwyer DE. J Clin Virol; 1999 Oct; 14(2):87-94. PubMed ID: 10588451 [Abstract] [Full Text] [Related]
10. Clinical comparison of branched DNA and reverse transcriptase-PCR and nucleic acid sequence-based amplification assay for the quantitation of circulating recombinant form_BC HIV-1 RNA in plasma. Pan P, Tao X, Zhang Q, Xing W, Sun X, Pei L, Jiang Y. AIDS; 2007 Dec; 21 Suppl 8():S27-32. PubMed ID: 18172387 [Abstract] [Full Text] [Related]
11. Using RT-PCR and bDNA assays to measure non-clade B HIV-1 subtype RNA. Pasquier C, Sandres K, Salama G, Puel J, Izopet J. J Virol Methods; 1999 Aug; 81(1-2):123-9. PubMed ID: 10488770 [Abstract] [Full Text] [Related]