21. Evaluation of the Greiner Bio-One serum separator BCA Fast Clot tube. Dimeski G, Johnston J, Masci PP, Zhao KN, Brown N. Clin Chem Lab Med; 2017 Jul 26; 55(8):1135-1141. PubMed ID: 28076307 [Abstract] [Full Text] [Related]
22. Do evacuated blood collection tubes interfere with therapeutic drug monitoring? Janknegt R, Lohman JJ, Hooymans PM, Merkus FW. Pharm Weekbl Sci; 1983 Dec 16; 5(6):287-90. PubMed ID: 6664820 [Abstract] [Full Text] [Related]
23. Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum. Bergqvist Y, Eckerbom S, Funding L. Clin Chem; 1984 Mar 16; 30(3):465-6. PubMed ID: 6697500 [Abstract] [Full Text] [Related]
24. Comparative effects of two commercially available blood collection tubes on plasma concentrations of drugs. Steyn JM, Müller FO. S Afr Med J; 1980 Jan 26; 57(4):129-31. PubMed ID: 6773155 [Abstract] [Full Text] [Related]
26. Differential effect of blood collection tubes on total free fatty acids (FFA) and total triiodothyronine (TT3) concentration: a model for studying interference from tube constituents. Bowen RA, Vu C, Remaley AT, Hortin GL, Csako G. Clin Chim Acta; 2007 Mar 26; 378(1-2):181-93. PubMed ID: 17234171 [Abstract] [Full Text] [Related]
28. Preparation of serum and plasma samples for determination of tricyclic antidepressants: effects of blood collection tubes and storage. Nyberg G, Mårtensson E. Ther Drug Monit; 1986 Mar 26; 8(4):478-82. PubMed ID: 3824436 [Abstract] [Full Text] [Related]
29. Where clinical chemistry meets medicinal chemistry. Systematic analysis of physico-chemical properties predicts stability of common used drugs in gel separator serum tubes. Steuer C, Huber AR, Bernasconi L. Clin Chim Acta; 2016 Nov 01; 462():23-27. PubMed ID: 27567701 [Abstract] [Full Text] [Related]
30. Stability of oleander extract and oleandrin in sera stored in plastic serum separator tubes. Dasgupta A, White D. Ann Clin Biochem; 2007 Sep 01; 44(Pt 5):485-7. PubMed ID: 17761037 [Abstract] [Full Text] [Related]
31. Monoject Samplette capillary blood container with serum separator evaluated for collection of specimens for therapeutic drug assays and common clinical-chemical tests. Landt M, Norling LL, Steelman M, Smith CH. Clin Chem; 1986 Mar 01; 32(3):523-6. PubMed ID: 3948399 [Abstract] [Full Text] [Related]
32. Implementation of biological variation-based analytical performance specifications in the laboratory: Stringent evaluation of Improvacutor blood collection tubes. Chung HJ, Song YK, Hong SK, Hwang SH, Seo HS, Whang DH, Nam MH, Lee DH. PLoS One; 2017 Mar 01; 12(12):e0189882. PubMed ID: 29261759 [Abstract] [Full Text] [Related]
33. Erroneous detection of hypercalcemia in specimens stored in Greiner Bio-One Vacuette Plasma Separator Tubes and analyzed by the Arsenazo III methodology. Ritter D, Mayo MM. Arch Pathol Lab Med; 2009 Sep 01; 133(9):1363-4. PubMed ID: 19722736 [No Abstract] [Full Text] [Related]
34. Effect of blood sample tubes on amiodarone and desethylamiodarone concentrations. Siebers RW, Chen CT, Ferguson RI, Maling TJ. Ther Drug Monit; 1988 Sep 01; 10(3):349-51. PubMed ID: 3176114 [Abstract] [Full Text] [Related]
35. Suitability of Becton Dickinson Vacutainer rapid serum tube for collecting and storing blood samples for antibiotic and anticonvulsant drug monitoring. Yan R, Colantonio D, Wong PY, Chen Y. J Clin Pathol; 2014 Sep 01; 67(9):807-10. PubMed ID: 24989025 [Abstract] [Full Text] [Related]
36. Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use. O'Keane MP, Cunningham SK. Clin Chem Lab Med; 2006 Sep 01; 44(5):662-8. PubMed ID: 16681442 [Abstract] [Full Text] [Related]
37. Clotting time analysis of citrated blood samples is strongly affected by the tube used for blood sampling. Ramström S. Blood Coagul Fibrinolysis; 2005 Sep 01; 16(6):447-52. PubMed ID: 16093737 [Abstract] [Full Text] [Related]
38. Suitability of collection tubes with separator gels for collecting and storing blood samples for therapeutic drug monitoring (TDM). Karppi J, Akerman KK, Parviainen M. Clin Chem Lab Med; 2000 Apr 01; 38(4):313-20. PubMed ID: 10928651 [Abstract] [Full Text] [Related]
39. Comparison of BD Vacutainer SST Plus Tubes with BD SST II Plus Tubes for common analytes. Bush VJ, Janu MR, Bathur F, Wells A, Dasgupta A. Clin Chim Acta; 2001 Apr 01; 306(1-2):139-43. PubMed ID: 11282105 [Abstract] [Full Text] [Related]
40. Effects of storage temperature and time before centrifugation on ionized calcium in blood collected in plain vacutainer tubes and silicone-separator (SST) tubes. Toffaletti J, Blosser N, Kirvan K. Clin Chem; 1984 Apr 01; 30(4):553-6. PubMed ID: 6705198 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]