These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


246 related items for PubMed ID: 10953268

  • 1. Implantable dual-chamber cardioverter-defibrillator-pacemaker.
    Pfeiffer D, Mende M, Hagendorff A.
    Curr Cardiol Rep; 2000 Jul; 2(4):335-40. PubMed ID: 10953268
    [Abstract] [Full Text] [Related]

  • 2. The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial: rationale, design, results, clinical implications and lessons for future trials.
    Wilkoff BL, Dual Chamber and VVI Implantable Defibrillator trial investigators.
    Card Electrophysiol Rev; 2003 Dec; 7(4):468-72. PubMed ID: 15071277
    [Abstract] [Full Text] [Related]

  • 3. Reduced risk for inappropriate implantable cardioverter-defibrillator shocks with dual-chamber therapy compared with single-chamber therapy: results of the randomized OPTION study.
    Kolb C, Sturmer M, Sick P, Reif S, Davy JM, Molon G, Schwab JO, Mantovani G, Dan D, Lennerz C, Borri-Brunetto A, Babuty D.
    JACC Heart Fail; 2014 Dec; 2(6):611-9. PubMed ID: 25282033
    [Abstract] [Full Text] [Related]

  • 4. Indications for dual-chamber (DDD) pacing in implantable cardioverter-defibrillator patients.
    Santini M, Ansalone G, Auriti A, Magris B, Pandozi C, Altamura G.
    Am J Cardiol; 1996 Sep 12; 78(5A):116-8. PubMed ID: 8820847
    [Abstract] [Full Text] [Related]

  • 5. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.
    Wilkoff BL, Cook JR, Epstein AE, Greene HL, Hallstrom AP, Hsia H, Kutalek SP, Sharma A, Dual Chamber and VVI Implantable Defibrillator Trial Investigators.
    JAMA; 2002 Dec 25; 288(24):3115-23. PubMed ID: 12495391
    [Abstract] [Full Text] [Related]

  • 6. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.
    Dijkman B, Wellens HJ.
    J Interv Card Electrophysiol; 2001 Sep 25; 5(3):309-18. PubMed ID: 11500586
    [Abstract] [Full Text] [Related]

  • 7. [The concurrent implantation of a last-generation automatic defibrillator and a 2-chamber pacemaker].
    Cesario AS, Palermo P, Baragli D, Amici E, Biancalana G, Gambelli G, Neri R.
    G Ital Cardiol; 1998 Aug 25; 28(8):878-86. PubMed ID: 9773313
    [Abstract] [Full Text] [Related]

  • 8. Efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias in patients with life-threatening ventricular tachyarrhythmias.
    Ricci R, Pignalberi C, Disertori M, Capucci A, Padeletti L, Botto G, Toscano S, Miraglia F, Grammatico A, Santini M.
    Eur Heart J; 2002 Sep 25; 23(18):1471-9. PubMed ID: 12208228
    [Abstract] [Full Text] [Related]

  • 9. Implantable cardioverter-defibrillators.
    Pinski SL, Fahy GJ.
    Am J Med; 1999 Apr 25; 106(4):446-58. PubMed ID: 10225249
    [Abstract] [Full Text] [Related]

  • 10. Should all implantable cardioverter defibrillators for ventricular arrhythmias be dual-chamber devices?
    Lee KL, Lau CP.
    Curr Cardiol Rep; 2001 Nov 25; 3(6):447-50. PubMed ID: 11602074
    [Abstract] [Full Text] [Related]

  • 11. Comparison of Inappropriate Shocks and Other Health Outcomes Between Single- and Dual-Chamber Implantable Cardioverter-Defibrillators for Primary Prevention of Sudden Cardiac Death: Results From the Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter-Defibrillators.
    Peterson PN, Greenlee RT, Go AS, Magid DJ, Cassidy-Bushrow A, Garcia-Montilla R, Glenn KA, Gurwitz JH, Hammill SC, Hayes J, Kadish A, Reynolds K, Sharma P, Smith DH, Varosy PD, Vidaillet H, Zeng CX, Normand ST, Masoudi FA.
    J Am Heart Assoc; 2017 Nov 09; 6(11):. PubMed ID: 29122811
    [Abstract] [Full Text] [Related]

  • 12. Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator.
    Adler SW, Wolpert C, Warman EN, Musley SK, Koehler JL, Euler DE.
    Circulation; 2001 Aug 21; 104(8):887-92. PubMed ID: 11514374
    [Abstract] [Full Text] [Related]

  • 13. The value of DDD pacing in patients with an implantable cardioverter defibrillator.
    Geelen P, Lorga Filho A, Chauvin M, Wellens F, Brugada P.
    Pacing Clin Electrophysiol; 1997 Jan 21; 20(1 Pt 2):177-81. PubMed ID: 9121985
    [Abstract] [Full Text] [Related]

  • 14. [Clinical evaluation of a dual chamber implantable cardioverter-defibrillator].
    Kazmierczak J, Tavernier R, De Sutter J, Jordaens L.
    Pol Merkur Lekarski; 2000 Aug 21; 9(50):522-6. PubMed ID: 11081315
    [Abstract] [Full Text] [Related]

  • 15. Efficacy of atrial antitachycardia functions for treating atrial fibrillation: observations in patients with a dual-chamber defibrillator.
    Ricci R, Pignalberi C, Santini M.
    Card Electrophysiol Rev; 2003 Dec 21; 7(4):348-51. PubMed ID: 15071251
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 13.