These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


137 related items for PubMed ID: 11129081

  • 1. Liquid-phase microextraction as a sample preparation technique prior to capillary gas chromatographic-determination of benzodiazepines in biological matrices.
    Ugland HG, Krogh M, Rasmussen KE.
    J Chromatogr B Biomed Sci Appl; 2000 Nov 10; 749(1):85-92. PubMed ID: 11129081
    [Abstract] [Full Text] [Related]

  • 2. Determination of benzodiazepines in human urine and plasma with solvent modified solid phase micro extraction and gas chromatography; rationalisation of method development using experimental design strategies.
    Reubsaet KJ, Ragnar Norli H, Hemmersbach P, Rasmussen KE.
    J Pharm Biomed Anal; 1998 Dec 10; 18(4-5):667-80. PubMed ID: 9919968
    [Abstract] [Full Text] [Related]

  • 3. Solvent-modified solid-phase microextraction for the determination of diazepam in human plasma samples by capillary gas chromatography.
    Krogh M, Grefslie H, Rasmussen KE.
    J Chromatogr B Biomed Sci Appl; 1997 Feb 21; 689(2):357-64. PubMed ID: 9080322
    [Abstract] [Full Text] [Related]

  • 4. Development of a simple in-vial liquid-phase microextraction device for drug analysis compatible with capillary gas chromatography, capillary electrophoresis and high-performance liquid chromatography.
    Rasmussen KE, Pedersen-Bjergaard S, Krogh M, Ugland HG, Grønhaug T.
    J Chromatogr A; 2000 Mar 17; 873(1):3-11. PubMed ID: 10757280
    [Abstract] [Full Text] [Related]

  • 5. Sensitive determination of diazepam and N-desmethyldiazepam in human material using capillary gas chromatography-mass spectrometry.
    Kudo K, Nagata T, Kimura K, Imamura T, Noda M.
    J Chromatogr; 1988 Oct 14; 431(2):353-9. PubMed ID: 3149641
    [Abstract] [Full Text] [Related]

  • 6. Analysis of endocrine disrupting alkylphenols, chlorophenols and bisphenol-A using hollow fiber-protected liquid-phase microextraction coupled with injection port-derivatization gas chromatography-mass spectrometry.
    Basheer C, Lee HK.
    J Chromatogr A; 2004 Nov 19; 1057(1-2):163-9. PubMed ID: 15584235
    [Abstract] [Full Text] [Related]

  • 7. High-throughput determination of nicotine in plasma by ultrasonication enhanced hollow fiber liquid-phase microextraction prior to gas chromatography.
    Liu X, Liang S, Pan J, Guo Y, Luo H, Zhao Q, Guan S.
    J Chromatogr Sci; 2014 Jul 19; 52(6):553-8. PubMed ID: 23794719
    [Abstract] [Full Text] [Related]

  • 8. Determination of organophosphorus pesticides and metabolites in cereal-based baby foods and wheat flour by means of ultrasound-assisted extraction and hollow-fiber liquid-phase microextraction prior to gas chromatography with nitrogen phosphorus detection.
    González-Curbelo MÁ, Hernández-Borges J, Borges-Miquel TM, Rodríguez-Delgado MÁ.
    J Chromatogr A; 2013 Oct 25; 1313():166-74. PubMed ID: 23809845
    [Abstract] [Full Text] [Related]

  • 9. Monitoring diazepam and desmethyldiazepam concentrations in plasma by gas-liquid chromatography, with use of a nitrogen-sensitive detector.
    Dhar AK, Kutt H.
    Clin Chem; 1979 Jan 25; 25(1):137-40. PubMed ID: 367633
    [Abstract] [Full Text] [Related]

  • 10. Rapid micro-method for the measurement of diazepam and desmethyldiazepam in blood plasma by gas-liquid chromatography.
    Rutherford DM.
    J Chromatogr; 1977 Jul 21; 137(2):439-48. PubMed ID: 328523
    [Abstract] [Full Text] [Related]

  • 11. Improved method for the determination of diazepam and N-desmethyldiazepam in plasma using capillary gas chromatography and nitrogen-phosphorus detection.
    Karnes HT, Beightol LA, Serafin RJ, Farthing D.
    J Chromatogr; 1988 Feb 26; 424(2):398-402. PubMed ID: 3131377
    [No Abstract] [Full Text] [Related]

  • 12. Recovery, enrichment and selectivity in liquid-phase microextraction comparison with conventional liquid-liquid extraction.
    Ho TS, Pedersen-Bjergaard S, Rasmussen KE.
    J Chromatogr A; 2002 Jul 19; 963(1-2):3-17. PubMed ID: 12187984
    [Abstract] [Full Text] [Related]

  • 13. Sensitive gas chromatographic method for the determination of diazepam and N-desmethyldiazepam in plasma.
    de Gier JJ, 't Hart BJ.
    J Chromatogr; 1979 Jul 21; 163(3):304-9. PubMed ID: 120374
    [No Abstract] [Full Text] [Related]

  • 14. Green aspects, developments and perspectives of liquid phase microextraction techniques.
    Spietelun A, Marcinkowski Ł, de la Guardia M, Namieśnik J.
    Talanta; 2014 Feb 21; 119():34-45. PubMed ID: 24401382
    [Abstract] [Full Text] [Related]

  • 15. Development and application of microporous hollow fiber protected liquid-phase microextraction via gaseous diffusion to the determination of phenols in water.
    Zhang J, Su T, Lee HK.
    J Chromatogr A; 2006 Jul 14; 1121(1):10-5. PubMed ID: 16696990
    [Abstract] [Full Text] [Related]

  • 16. Automated on-line solid-phase extraction-gas chromatography with nitrogen-phosphorus detection: determination of benzodiazepines in human plasma.
    Louter AJ, Bosma E, Schipperen JC, Vreuls JJ, Brinkman UA.
    J Chromatogr B Biomed Sci Appl; 1997 Feb 07; 689(1):35-43. PubMed ID: 9061480
    [Abstract] [Full Text] [Related]

  • 17. Simultaneous gas-chromatographic analysis for diazepam and its major metabolite, desmethyldiazepam, with use of double internal standardization.
    Greenblatt DJ.
    Clin Chem; 1978 Oct 07; 24(10):1838-41. PubMed ID: 359197
    [Abstract] [Full Text] [Related]

  • 18. Determination of diazepam and nordazepam in milk and plasma in the presence of oxazepam and temazepam.
    Stebler T, Guentert TW.
    J Chromatogr; 1991 Mar 08; 564(1):330-7. PubMed ID: 1860930
    [Abstract] [Full Text] [Related]

  • 19. Hollow Fiber Liquid-Phase Microextraction At-Line Coupled to Capillary Electrophoresis for Direct Analysis of Human Body Fluids.
    Miková B, Dvořák M, Ryšavá L, Kubáň P.
    Anal Chem; 2020 May 19; 92(10):7171-7178. PubMed ID: 32289222
    [Abstract] [Full Text] [Related]

  • 20. Extraction of trace amounts of pioglitazone as an anti-diabetic drug with hollow fiber liquid phase microextraction and determination by high-performance liquid chromatography-ultraviolet detection in biological fluids.
    Tahmasebi E, Yamini Y, Saleh A.
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Jul 01; 877(20-21):1923-9. PubMed ID: 19501030
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.