These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. McKellop H, Shen FW, Lu B, Campbell P, Salovey R. J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831 [Abstract] [Full Text] [Related]
5. In vivo change of elastic property in polyethylene acetabular components. Kusaba A, Kondo S, Mori Y, Kuroki Y. Mod Rheumatol; 2008 Mar; 18(2):140-5. PubMed ID: 18292965 [Abstract] [Full Text] [Related]
7. Wear of '100 Mrad' cross-linked polyethylene: effects of packaging after 30 years real-time shelf-aging. Kyomoto M, Ueno M, Kim SC, Oonishi H, Oonishi H. J Biomater Sci Polym Ed; 2007 Dec; 18(1):59-70. PubMed ID: 17274451 [Abstract] [Full Text] [Related]
8. Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator. Affatato S, Bordini B, Fagnano C, Taddei P, Tinti A, Toni A. Biomaterials; 2002 Mar; 23(6):1439-46. PubMed ID: 11829439 [Abstract] [Full Text] [Related]
10. Conventional ultra-high molecular weight polyethylene: a gold standard of sorts. Engh CA, Sychterz CJ, Engh CA. Instr Course Lect; 2005 Apr; 54():183-7. PubMed ID: 15948445 [Abstract] [Full Text] [Related]
11. The influence of inert packaging on the shelf ageing of gamma-irradiation sterilised ultra-high molecular weight polyethylene. Lu S, Orr JF, Buchanan FJ. Biomaterials; 2003 Jan; 24(1):139-45. PubMed ID: 12417187 [Abstract] [Full Text] [Related]
12. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene. Sakoda H, Voice AM, McEwen HM, Isaac GH, Hardaker C, Wroblewski BM, Fisher J. J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757 [Abstract] [Full Text] [Related]
13. The pros and cons of polyethylene sterilization with gamma irradiation. Hopper RH, Engh CA, Fowlkes LB, Engh CA. Clin Orthop Relat Res; 2004 Dec; (429):54-62. PubMed ID: 15577466 [Abstract] [Full Text] [Related]
14. Oxidation and wear of 100-Mrad cross-linked polyethylene shelf-aged for 30 years. Oonishi H, Kim SC, Oonishi H, Kyomoto M, Masuda S. Clin Orthop Relat Res; 2008 Feb; 466(2):347-52. PubMed ID: 18196416 [Abstract] [Full Text] [Related]
15. A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE. Besong AA, Hailey JL, Ingham E, Stone M, Wroblewski BM, Fisher J. Biomed Mater Eng; 1997 Feb; 7(1):59-65. PubMed ID: 9171903 [Abstract] [Full Text] [Related]
16. The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners. Wannomae KK, Christensen SD, Freiberg AA, Bhattacharyya S, Harris WH, Muratoglu OK. Biomaterials; 2006 Mar; 27(9):1980-7. PubMed ID: 16271756 [Abstract] [Full Text] [Related]
17. Surface-gradient cross-linked polyethylene acetabular cups: oxidation resistance and wear against smooth and rough femoral balls. Shen FW, McKellop H. Clin Orthop Relat Res; 2005 Jan; (430):80-8. PubMed ID: 15662307 [Abstract] [Full Text] [Related]
18. The performance of gamma- and EtO-sterilised UHWMPE acetabular cups tested under severe simulator conditions. Part 1: role of the third-body wear process. Affatato S, Bersaglia G, Foltran I, Taddei P, Fini G, Toni A. Biomaterials; 2002 Dec; 23(24):4839-46. PubMed ID: 12361624 [Abstract] [Full Text] [Related]
19. Behavior of Hylamer polyethylene in hip arthroplasty: comparison of two gamma sterilization techniques. Stea S, Antonietti B, Baruffaldi F, Visentin M, Bordini B, Sudanese A, Toni A. Int Orthop; 2006 Feb; 30(1):35-8. PubMed ID: 16217685 [Abstract] [Full Text] [Related]
20. Nonconsolidated polyethylene particles and oxidation in Charnley acetabular cups. Li S, Chang JD, Barrena EG, Furman BD, Wright TM, Salvati E. Clin Orthop Relat Res; 1995 Oct; (319):54-63. PubMed ID: 7554650 [Abstract] [Full Text] [Related] Page: [Next] [New Search]