These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. [Metabolic parameters in the evaluation of frequency-adaptive sensors in pacemakers]. Pavlović SU, Velimirović D, Rebić P, Baute V, Zivković MB, Stojanov P, Jelić V, Milasinović G. Srp Arh Celok Lek; 2000; 128(7-8):229-33. PubMed ID: 11089428 [Abstract] [Full Text] [Related]
3. Direct comparison of a contractility and activity pacemaker sensor during treadmill exercise testing. Erol-Yilmaz A, Tukkie R, De Boo J, Schrama T, Wilde A. Pacing Clin Electrophysiol; 2004 Nov; 27(11):1493-9. PubMed ID: 15546303 [Abstract] [Full Text] [Related]
4. Effects of sildenafil on cardiopulmonary responses during stress. Stanopoulos I, Hatzichristou D, Tryfon S, Tzortzis V, Apostolidis A, Argyropoulou P. J Urol; 2003 Apr; 169(4):1417-21. PubMed ID: 12629375 [Abstract] [Full Text] [Related]
5. [Improvement in oxygen consumption by frequency-adjusted pacemaker stimulation: effect of intrinsic heart rate]. Schlegl M, Matula M, Alt E. Z Kardiol; 1994 Dec; 83(12):912-20. PubMed ID: 7846930 [Abstract] [Full Text] [Related]
6. [Ergospirometric findings in respiration- and QT-controlled pacemakers]. Sigmund M, van Erckelens F, Reupcke C, Heiermann B, Hanrath P. Z Kardiol; 1994 Dec; 83 Suppl 3():145-8. PubMed ID: 7941662 [Abstract] [Full Text] [Related]
7. Proportionality of rate response to metabolic workload provided by a rate adaptive pacemaker with automatic rate profile optimization. Schuster P, Faerestrand S, Ohm OJ, Schouten V. Europace; 2005 Jan; 7(1):54-9. PubMed ID: 15670968 [Abstract] [Full Text] [Related]
8. The effect of maximum heart rate on oxygen kinetics and exercise performance at low and high workloads. Carmouche DG, Bubien RS, Kay GN. Pacing Clin Electrophysiol; 1998 Apr; 21(4 Pt 1):679-86. PubMed ID: 9584297 [Abstract] [Full Text] [Related]
9. The contribution of rate adaptive pacing with single or dual sensors to health-related quality of life. van Hemel NM, Holwerda KJ, Slegers PC, Spierenburg HA, Timmermans AA, Meeder JG, van der Kemp P, Kelder JC, Stofmeel MA, Sensor and Quality of Life (SQL) Investigators. Europace; 2007 Apr; 9(4):233-8. PubMed ID: 17350981 [Abstract] [Full Text] [Related]
10. Impact of cardiac resynchronisation therapy on adaptation of circulatory and respiratory systems to exercise assessed by cardiopulmonary exercise test in patients with chronic heart failure. Chwyczko T, Sterliński M, Maciag A, Firek B, Labecka A, Jankowska A, Kośmicki M, Kowalik I, Malczewska B, Szwed H. Kardiol Pol; 2008 Apr; 66(4):406-12; discussion 413-4. PubMed ID: 18473269 [Abstract] [Full Text] [Related]
11. Predictors of chronotropic incompetence in the pacemaker patient population. Melzer C, Witte J, Reibis R, Bondke HJ, Combs W, Stangl K, Baumann G, Theres H. Europace; 2006 Jan; 8(1):70-5. PubMed ID: 16627413 [Abstract] [Full Text] [Related]
12. [Shortening the stimulus T time: indicator for physical activity in patients with demand modulated cardiac pacemakers]. Schuchert A, Kuck KH. Z Kardiol; 1993 Jun; 82(6):358-61. PubMed ID: 8351941 [Abstract] [Full Text] [Related]
13. Optimal maximum tracking rate of dual-chamber pacemakers required by children and young adults for a maximal cardiorespiratory performance. Mathony U, Schmidt H, Gröger C, Francis DP, Konzag I, Müller-Werdan U, Werdan K, Syska J. Pacing Clin Electrophysiol; 2005 May; 28(5):378-83. PubMed ID: 15869668 [Abstract] [Full Text] [Related]
14. [Dual chamber rate responsive pacing and chronotropic insufficiency. Comparison of double and respiratory sensors]. Lascault G, Pansard Y, Scholl JM, Abraham P, Dupuis JM, Victor J, Copie X, Alonso C, Sarrazin E. Arch Mal Coeur Vaiss; 2001 Mar; 94(3):190-5. PubMed ID: 11338253 [Abstract] [Full Text] [Related]
15. Effects of supervised cardiovascular training program on exercise tolerance, aerobic capacity, and quality of life in patients with systemic lupus erythematosus. Carvalho MR, Sato EI, Tebexreni AS, Heidecher RT, Schenkman S, Neto TL. Arthritis Rheum; 2005 Dec 15; 53(6):838-44. PubMed ID: 16342102 [Abstract] [Full Text] [Related]
16. Improvement in exercise performance after successful cardioversion in patients with persistent atrial fibrillation and symptoms of heart failure. Wozakowska-Kapłon B, Opolski G. Kardiol Pol; 2003 Sep 15; 59(9):213-23. PubMed ID: 14618198 [Abstract] [Full Text] [Related]
17. Quantitative comparison of rate response and oxygen uptake kinetics between different sensor modes in multisensor rate adaptive pacing. Leung SK, Lau CP, Wu CW, Leung WH, Tai YT, Lee I, Chow YH. Pacing Clin Electrophysiol; 1994 Nov 15; 17(11 Pt 2):1920-7. PubMed ID: 7845792 [Abstract] [Full Text] [Related]
18. Ventilation and its control during incremental exercise in obesity. Salvadori A, Fanari P, Tovaglieri I, Giacomotti E, Nibbio F, Belardi F, Longhini E. Respiration; 2008 Nov 15; 75(1):26-33. PubMed ID: 17114876 [Abstract] [Full Text] [Related]
19. Methodological aspects of crossover and maximum fat-oxidation rate point determination. Michallet AS, Tonini J, Regnier J, Guinot M, Favre-Juvin A, Bricout V, Halimi S, Wuyam B, Flore P. Diabetes Metab; 2008 Nov 15; 34(5):514-23. PubMed ID: 18823806 [Abstract] [Full Text] [Related]
20. Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study. Kantharia BK, Freedman RA, Hoekenga D, Tomassoni G, Worley S, Sorrentino R, Steinhaus D, Wolkowicz JM, Syed ZA, AOP Study Investigators. Europace; 2007 Nov 15; 9(11):1024-30. PubMed ID: 17913697 [Abstract] [Full Text] [Related] Page: [Next] [New Search]