7. Selective atrial sensing in dual chamber pacemakers eliminates endless loop tachycardia. Klementowicz PT, Furman S. J Am Coll Cardiol; 1986 Mar; 7(3):590-4. PubMed ID: 3753992 [Abstract] [Full Text] [Related]
8. The dynamic nature of ventriculoatrial conduction. Klementowicz P, Ausubel K, Furman S. Pacing Clin Electrophysiol; 1986 Nov; 9(6):1050-4. PubMed ID: 2432508 [Abstract] [Full Text] [Related]
9. Retrograde (ventriculoatrial) conduction in congenital complete heart block. Zilo P, Gross JN, Andrews CA, Furman S. Pacing Clin Electrophysiol; 1991 Oct; 14(10):1538-43. PubMed ID: 1721136 [Abstract] [Full Text] [Related]
10. Potential triggering of repetitive nonreentrant ventriculoatrial synchrony by loss of atrial capture. Atar AI, Atar I. Ann Noninvasive Electrocardiol; 2023 Jan; 28(1):e13033. PubMed ID: 36534029 [Abstract] [Full Text] [Related]
12. First-degree atrioventricular block. Clinical manifestations, indications for pacing, pacemaker management & consequences during cardiac resynchronization. Barold SS, Ilercil A, Leonelli F, Herweg B. J Interv Card Electrophysiol; 2006 Nov; 17(2):139-52. PubMed ID: 17334913 [Abstract] [Full Text] [Related]
13. Effect of atrioventricular sequential pacing in patients with no ventriculoatrial conduction. Mahmud R, Denker S, Lehmann MH, Akhtar M. J Am Coll Cardiol; 1984 Aug; 4(2):273-7. PubMed ID: 6736468 [Abstract] [Full Text] [Related]
15. Improved method for evaluating ventriculoatrial conduction before implantation of atrial-sensing dual chamber pacemakers. Webb CR, Spielman SR, Greenspan AM, Yacone LA, Horowitz LN. J Am Coll Cardiol; 1985 Jun; 5(6):1395-402. PubMed ID: 3998321 [Abstract] [Full Text] [Related]
16. Noninvasive evaluation of retrograde conduction times to avoid pacemaker-mediated tachycardia. Greenspon AJ, Greenberg RM. J Am Coll Cardiol; 1985 Jun; 5(6):1403-6. PubMed ID: 3998322 [Abstract] [Full Text] [Related]
17. Endless loop tachycardia started by an atrial premature complex in a patient with a dual chamber pacemaker. Frumin H, Furman S. J Am Coll Cardiol; 1985 Mar; 5(3):707-10. PubMed ID: 3838323 [Abstract] [Full Text] [Related]
18. Ventriculoatrial conduction and related pacemaker-mediated arrhythmias in patients implanted for atrioventricular block: an old problem revisited. Richter S, Muessigbrodt A, Salmas J, Doering M, Wetzel U, Arya A, Hindricks G, Brugada P, Israel CW. Int J Cardiol; 2013 Oct 09; 168(4):3300-8. PubMed ID: 23639463 [Abstract] [Full Text] [Related]
19. Differentiating pacemaker-mediated tachycardia from tachycardia due to atrial tracking: utility of V-A-A-V versus V-A-V response after postventricular atrial refractory period extension. Ip JE, Markowitz SM, Liu CF, Cheung JW, Thomas G, Lerman BB. Heart Rhythm; 2011 Aug 09; 8(8):1185-91. PubMed ID: 21376834 [Abstract] [Full Text] [Related]
20. Noninvasive measurement of retrograde conduction times in pacemaker patients. Marco DD, Gallagher D. Pacing Clin Electrophysiol; 1988 Nov 09; 11(11 Pt 2):1673-8. PubMed ID: 2463531 [Abstract] [Full Text] [Related] Page: [Next] [New Search]