These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Gas exchange in a three-compartment lung model analyzed by forcing sinusoids of N2O. Hahn CE, Black AM, Barton SA, Scott I. J Appl Physiol (1985); 1993 Oct; 75(4):1863-76. PubMed ID: 8282644 [Abstract] [Full Text] [Related]
3. Estimation of pulmonary blood flow from sinusoidal gas exchange during anaesthesia: a theoretical study. Turner MJ, Weismann D, Járos GG, Baker AB. Br J Anaesth; 2000 Sep; 85(3):371-8. PubMed ID: 11103177 [Abstract] [Full Text] [Related]
4. An IBM PC-based system for the assessment of cardio-respiratory function using oscillating inert gas forcing signals. Wong LS, Williams EM, Hamilton R, Hahn CE. J Clin Monit Comput; 2000 Jan; 16(1):33-43. PubMed ID: 12578093 [Abstract] [Full Text] [Related]
5. A new noninvasive method for the simultaneous determination of cardiac output, VA/QC disparity, and the magnitude of peripheral perfusion, suitable for use in the critically ill patient. Geisler FH, Farrell EJ, Siegel JH. J Trauma; 1978 Nov; 18(11):751-65. PubMed ID: 712870 [Abstract] [Full Text] [Related]
6. A closed lung system study of inert gas absorption. Johnson TS, Swanson GD, Sodal IE, Reeves JT, Virtue RW. J Appl Physiol Respir Environ Exerc Physiol; 1979 Jul; 47(1):240-4. PubMed ID: 468668 [Abstract] [Full Text] [Related]
7. Breath-by-breath variation of FRC: effect on VO2 and VCO2 measured at the mouth. Wessel HU, Stout RL, Bastanier CK, Paul MH. J Appl Physiol Respir Environ Exerc Physiol; 1979 Jun; 46(6):1122-6. PubMed ID: 468635 [Abstract] [Full Text] [Related]
8. On-line determination of pulmonary blood flow using respiratory inert gas analysis. Gan K, Nishi I, Chin I, Slutsky AS. IEEE Trans Biomed Eng; 1993 Dec; 40(12):1250-9. PubMed ID: 8125501 [Abstract] [Full Text] [Related]
9. Error due to dead-space admixture in single-breath method for estimation of pulmonary blood flow. Grønlund J, Christensen P. J Appl Physiol (1985); 1985 Mar; 58(3):1034-9. PubMed ID: 3980375 [Abstract] [Full Text] [Related]
10. Theoretical basis for time 0 correction in the rebreathing analysis. Verbanck S, Paiva M. J Appl Physiol (1985); 1994 Jan; 76(1):445-54. PubMed ID: 8175543 [Abstract] [Full Text] [Related]
11. Gas uptake from an unventilated area of lung: computer model of absorption atelectasis. Joyce CJ, Baker AB, Kennedy RR. J Appl Physiol (1985); 1993 Mar; 74(3):1107-16. PubMed ID: 8482648 [Abstract] [Full Text] [Related]
12. Pulmonary blood flow (cardiac output) and the effective lung volume determined from a short breath hold using the differential Fick method. Gedeon A, Krill P, Osterlund B. J Clin Monit Comput; 2002 Jul; 17(5):313-21. PubMed ID: 12546265 [Abstract] [Full Text] [Related]
13. Assessment of cardiorespiratory function using oscillating inert gas forcing signals. Williams EM, Aspel JB, Burrough SM, Ryder WA, Sainsbury MC, Sutton L, Xiong L, Black AM, Hahn CE. J Appl Physiol (1985); 1994 May; 76(5):2130-9. PubMed ID: 8063677 [Abstract] [Full Text] [Related]
14. Breath-by-breath measurement of true alveolar gas exchange. Beaver WL, Lamarra N, Wasserman K. J Appl Physiol Respir Environ Exerc Physiol; 1981 Dec; 51(6):1662-75. PubMed ID: 6798003 [Abstract] [Full Text] [Related]
15. Addressing Assumptions for the Use of Non-invasive Cardiac Output Measurement Techniques During Exercise in COPD. Perrault H, Richard R, Kapchinsky S, Baril J, Bourbeau J, Taivassalo T. COPD; 2016 Dec; 13(1):75-81. PubMed ID: 26408087 [Abstract] [Full Text] [Related]
16. Pulmonary resistance in dogs: a comparison of xenon with nitrous oxide. Zhang P, Ohara A, Mashimo T, Imanaka H, Uchiyama A, Yoshiya I. Can J Anaesth; 1995 Jun; 42(6):547-53. PubMed ID: 7628038 [Abstract] [Full Text] [Related]
17. Uneven gas mixing during rebreathing assessed by simultaneously measuring dead space. Petrini MF, Peterson BT, Hyde RW, Lam V, Utell MJ, Kallay MC. J Appl Physiol Respir Environ Exerc Physiol; 1982 Oct; 53(4):930-9. PubMed ID: 7153127 [Abstract] [Full Text] [Related]
18. Quantitative recovery of expired nitrogen and nitrous oxide from venous gas emboli. Lechner AJ, Sherrill DL, Virtue RW. Pflugers Arch; 1983 May; 397(3):225-31. PubMed ID: 6878011 [Abstract] [Full Text] [Related]
19. Measurement of cardio-respiratory function using single frequency inspiratory gas concentration forcing signals. Williams EM, Hahn CE. Adv Exp Med Biol; 1994 May; 361():187-95. PubMed ID: 7597943 [No Abstract] [Full Text] [Related]
20. Cardiac output measurement using N2O uptake: a method to subtract cardiogenic oscillations. Dawson WT, Johnson RL. J Appl Physiol Respir Environ Exerc Physiol; 1983 May; 54(5):1427-33. PubMed ID: 6863102 [Abstract] [Full Text] [Related] Page: [Next] [New Search]