These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


225 related items for PubMed ID: 11282524

  • 1. [Evaluation of the XAS test for sera screening with visible interference in the ARS analyzer].
    Soulier Majidi M, Ciupek C, Blanchard M, Quillet P.
    Ann Biol Clin (Paris); 2001; 59(2):193-7. PubMed ID: 11282524
    [No Abstract] [Full Text] [Related]

  • 2. [Determination of normal values in multiphasic health screening--introduction of SMA-12/60 autoanalyzer and its application to multiphasic health screening].
    Sasaki T.
    Nihon Rinsho; 1971 Sep; 29(9):2048-57. PubMed ID: 5166012
    [No Abstract] [Full Text] [Related]

  • 3. [Assessment of the performance of an automated analysis system in detecting C3 and C4].
    Sun L, Huang XZ, Zhuang JH, Xu JH, Lin LY, Ke PF.
    Nan Fang Yi Ke Da Xue Xue Bao; 2009 May; 29(5):884-6. PubMed ID: 19460699
    [Abstract] [Full Text] [Related]

  • 4. [Influence of visible interferences on biochemical assays realised on Au 5231, AU 5223 (Olympus) and CL 7200 (Shimadzu)].
    Frémont S, Combe AM, Mecrin M, Tronel H, Galland AV, Scholl C, Nicolas JP.
    Ann Biol Clin (Paris); 1996 May; 54(8-9):309-20. PubMed ID: 9092310
    [Abstract] [Full Text] [Related]

  • 5. [Interference in the creatine kinase assay: the "wave" phenomenon].
    Cohen S.
    Ann Biol Clin (Paris); 2003 May; 61(3):328-31. PubMed ID: 12805011
    [No Abstract] [Full Text] [Related]

  • 6. [Influence of bilirubin and turbidity on main determinations performed on the Express 550 analyzer].
    Pontet F, Laudat A.
    Ann Biol Clin (Paris); 1997 May; 55(5):472-6. PubMed ID: 9347017
    [No Abstract] [Full Text] [Related]

  • 7. [Haemolysis and turbidity influence on three analysis methods of quantitative determination of total and conjugated bilirubin on ADVIA 1650].
    Gobert De Paepe E, Munteanu G, Schischmanoff PO, Porquet D.
    Ann Biol Clin (Paris); 2008 May; 66(2):175-82. PubMed ID: 18390427
    [Abstract] [Full Text] [Related]

  • 8. Evaluation of the VITROS 5,1 FS chemistry system in a large pediatric laboratory.
    Herkner K, Reiter-Reisacher R, Sonntag O.
    Clin Lab; 2007 May; 53(1-2):17-26. PubMed ID: 17323821
    [Abstract] [Full Text] [Related]

  • 9. Some aspects of bilirubin determination in the newborn using dimethyl sulfoxide.
    Baginski ES, Epstein E, Zak B.
    Ann Clin Lab Sci; 1980 May; 10(6):486-92. PubMed ID: 7447390
    [Abstract] [Full Text] [Related]

  • 10. [Analytic evaluation of Immage for ten proteins].
    Giraudeaux V, Fayard MF, Zerbani A.
    Ann Biol Clin (Paris); 1998 May; 56(5):593-8. PubMed ID: 9769496
    [No Abstract] [Full Text] [Related]

  • 11. Effect of hemolysis on insulin determination by the Beckman Coulter Unicell DXI 800 immunoassay analyzer.
    Cook PR, Glenn C, Armston A.
    Clin Biochem; 2010 Apr; 43(6):621-2. PubMed ID: 20080083
    [Abstract] [Full Text] [Related]

  • 12. Multicentre evaluation of KONE Optima analysis system.
    Ferrero C, Modenese A, Bonini PA, Ceriotti F, Carobene A, Franzin M, Guder WG, Hofmann W, Puukka M, Laitinen H, Makarovsky V, Gaidukova N.
    Clin Chem Lab Med; 1998 Jun; 36(7):475-84. PubMed ID: 9746273
    [Abstract] [Full Text] [Related]

  • 13. Evaluation of the interference due to haemoglobin, bilirubin and lipids on Immulite 2500 assays: a practical approach.
    Steen G, Klerk A, Laan Kv, Eppens EF.
    Ann Clin Biochem; 2011 Mar; 48(Pt 2):170-5. PubMed ID: 21355012
    [Abstract] [Full Text] [Related]

  • 14. [Automation of immunoglobulin determination and related problems].
    Miura H, Miyazawa K.
    Rinsho Byori; 1983 Aug; 31(8):802-8. PubMed ID: 6655914
    [No Abstract] [Full Text] [Related]

  • 15. Evaluation of the Dade Behring Dimension RxL clinical chemistry analyzer.
    Cuka S, Dvornik S, Drazenović K, Mihić J.
    Clin Lab; 2001 Aug; 47(1-2):35-40. PubMed ID: 11214221
    [Abstract] [Full Text] [Related]

  • 16. [Turbidimetric micromethod for the determination of the total lipids in blood serum].
    Shaternikov VA, Ekimovskiĭ AP.
    Vopr Pitan; 1975 Aug; (3):80. PubMed ID: 1154707
    [No Abstract] [Full Text] [Related]

  • 17. Interference of hemoglobin D on measurements of hemoglobin A1c by the high-performance liquid chromatography HA-8160 in 27 patients.
    Lorenzo-Medina M, De-La-Iglesia S, Ropero P, Martin-Alfaro R, Quintana-Hidalgo L.
    J Diabetes Sci Technol; 2012 Sep 01; 6(5):1235-7. PubMed ID: 23063052
    [No Abstract] [Full Text] [Related]

  • 18. Evaluation of bilirubin concentration in hemolysed samples, is it really impossible? The altitude-curve cartography approach to interfered assays.
    Brunori P, Masi P, Faggiani L, Villani L, Tronchin M, Galli C, Laube C, Leoni A, Demi M, La Gioia A.
    Clin Chim Acta; 2011 Apr 11; 412(9-10):774-7. PubMed ID: 21238446
    [Abstract] [Full Text] [Related]

  • 19. Evaluation of new oxidation methods for the measurement of bilirubin on the aeroset clinical chemistry analyzer and comparison with methods on the Hitachi 717.
    Sturm E, Albrecht-Groos R, Seyfarth M.
    Clin Lab; 2002 Apr 11; 48(7-8):401-5. PubMed ID: 12146574
    [Abstract] [Full Text] [Related]

  • 20. Serum bilirubin measurements in hemolyzed samples.
    McDonagh AF, Lo SF, Maisels MJ, Watchko JF.
    Clin Chim Acta; 2011 Jun 11; 412(13-14):1275; author reply 1276. PubMed ID: 21439950
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 12.