These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


168 related items for PubMed ID: 11341499

  • 1. Prothrombin time ratio is reduced by magnesium contamination in evacuated blood collection tubes.
    van den Besselaar AM, van Dam W, Sturk A, Bertina RM.
    Thromb Haemost; 2001 Apr; 85(4):647-50. PubMed ID: 11341499
    [Abstract] [Full Text] [Related]

  • 2. Effect of magnesium contamination in evacuated blood collection tubes on the prothrombin time test and ISI calibration using recombinant human thromboplastin and different types of coagulometer.
    van den Besselaar AM, Rutten WP, Witteveen E.
    Thromb Res; 2005 Apr; 115(3):239-44. PubMed ID: 15617747
    [Abstract] [Full Text] [Related]

  • 3. Comparative study of blood collection tubes and thromboplastin reagents for correction of INR discrepancies: a proposal for maximum allowable magnesium contamination in sodium citrate anticoagulant solutions.
    van den Besselaar AM, van Zanten AP, Brantjes HM, Elisen MG, van der Meer FJ, Poland DC, Sturk A, Leyte A, Castel A.
    Am J Clin Pathol; 2012 Aug; 138(2):248-54. PubMed ID: 22904137
    [Abstract] [Full Text] [Related]

  • 4. A comparative study of conventional versus new, magnesium-poor Vacutainer® Sodium Citrate blood collection tubes for determination of prothrombin time and INR.
    van den Besselaar AM, van Vlodrop IJ, Berendes PB, Cobbaert CM.
    Thromb Res; 2014 Jul; 134(1):187-91. PubMed ID: 24814970
    [Abstract] [Full Text] [Related]

  • 5. A comparison of two sodium citrate concentrations in two evacuated blood collection systems for prothrombin time and ISI determination.
    van den Besselaar AM, Chantarangkul V, Tripodi A.
    Thromb Haemost; 2000 Oct; 84(4):664-7. PubMed ID: 11057867
    [Abstract] [Full Text] [Related]

  • 6. Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.
    Horsti J.
    Haematologica; 2001 Aug; 86(8):851-5. PubMed ID: 11522542
    [Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. Influence of blood collection systems on the prothrombin time and international sensitivity index determined with human and rabbit thromboplastin reagents.
    van den Besselaar AM, Hoekstra MM, Witteveen E, Didden JH, van der Meer FJ.
    Am J Clin Pathol; 2007 May; 127(5):724-9. PubMed ID: 17439830
    [Abstract] [Full Text] [Related]

  • 9. The influence of exogenous magnesium chloride on the apparent INR determined with human, rabbit, and bovine thromboplastin reagents.
    van den Besselaar AM, Witteveen E, Meeuwisse-Braun J, van der Meer FJ.
    Thromb Haemost; 2003 Jan; 89(1):43-7. PubMed ID: 12540952
    [Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13. The response of Quick's prothrombin time test to oral anticoagulation. Influence of thromboplastin source and calcium chloride concentration.
    van den Besselaar AM.
    Arch Pathol Lab Med; 1994 Feb; 118(2):145-9. PubMed ID: 8311653
    [Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19. Multicenter evaluation of a bilayer polymer blood collection tube for coagulation testing: effect on routine hemostasis test results and on plasma levels of coagulation activation markers.
    Toulon P, Aillaud MF, Arnoux D, Boissier E, Borg JY, Gourmel C.
    Blood Coagul Fibrinolysis; 2006 Nov; 17(8):625-31. PubMed ID: 17102648
    [Abstract] [Full Text] [Related]

  • 20. How to evaluate the influence of blood collection systems on the international sensitivity index. Protocol applied to two new evacuated tubes and eight coagulometer/thromboplastin combinations.
    Tripodi A, Chantarangkul V, Bressi C, Mannucci PM.
    Thromb Res; 2002 Oct 01; 108(1):85-9. PubMed ID: 12586137
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.