These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
152 related items for PubMed ID: 11503125
1. Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty. Novotny J, Gonzalez MH, Amirouche FM, Li YC. J Arthroplasty; 2001 Aug; 16(5):641-7. PubMed ID: 11503125 [Abstract] [Full Text] [Related]
2. The variability of intramedullary alignment of the femoral component during total knee arthroplasty. Mihalko WM, Boyle J, Clark LD, Krackow KA. J Arthroplasty; 2005 Jan; 20(1):25-8. PubMed ID: 15660056 [Abstract] [Full Text] [Related]
3. The accuracy of femoral intramedullary guides in total knee arthroplasty. Reed SC, Gollish J. J Arthroplasty; 1997 Sep; 12(6):677-82. PubMed ID: 9306219 [Abstract] [Full Text] [Related]
7. Alignment of resection planes in total knee replacement obtained with the conventional technique, as assessed by a modern computer-based navigation system. Belvedere C, Ensini A, Leardini A, Bianchi L, Catani F, Giannini S. Int J Med Robot; 2007 Jun; 3(2):117-24. PubMed ID: 17619241 [Abstract] [Full Text] [Related]
10. A navigated 8-in-1 femoral cutting guide for total knee arthroplasty technical development and cadaveric evaluation. Kendoff DO, Moreau-Gaudry A, Plaskos C, Granchi C, Sculco TP, Pearle AD. J Arthroplasty; 2010 Jan; 25(1):138-45. PubMed ID: 19106033 [Abstract] [Full Text] [Related]
11. Three-dimensional analysis of alignment error in using femoral intramedullary guides in unicompartmental knee arthroplasty. Ma B, Long W, Rudan JF, Ellis RE. J Arthroplasty; 2006 Feb; 21(2):271-8. PubMed ID: 16520218 [Abstract] [Full Text] [Related]
12. Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches: a cadaver study. Yau WP, Leung A, Liu KG, Yan CH, Wong LS, Chiu KY. J Bone Joint Surg Br; 2008 Apr; 90(4):520-6. PubMed ID: 18378933 [Abstract] [Full Text] [Related]
17. How accurate is Whiteside's line as a reference axis in total knee arthroplasty? Middleton FR, Palmer SH. Knee; 2007 Jun; 14(3):204-7. PubMed ID: 17428665 [Abstract] [Full Text] [Related]
18. Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty: a study in 10 cadaver femora. Kort NP, van Raay JJ, Thomassen BJ. Knee; 2007 Aug; 14(4):280-3. PubMed ID: 17543531 [Abstract] [Full Text] [Related]
19. [The effect of rotational alignment of the femoral components on the patellofemoral biomechanics in total knee arthroplasty]. Chu XB, Wu HS, Xu CM, Zhu YL, Feng MG, He ZY. Zhonghua Wai Ke Za Zhi; 2006 Aug 15; 44(16):1136-40. PubMed ID: 17081473 [Abstract] [Full Text] [Related]
20. Cadaveric analysis of an accelerometer-based portable navigation device for distal femoral cutting block alignment in total knee arthroplasty. Nam D, Jerabek SA, Cross MB, Mayman DJ. Comput Aided Surg; 2012 Aug 15; 17(4):205-10. PubMed ID: 22681247 [Abstract] [Full Text] [Related] Page: [Next] [New Search]