These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


207 related items for PubMed ID: 115120

  • 1. The Clinac-18 linear accelerator. 10 MeV photon beam data.
    Bahr R, Nüsslin F.
    Strahlentherapie; 1979 Jul; 155(7):481-5. PubMed ID: 115120
    [Abstract] [Full Text] [Related]

  • 2. Optimization of photon beam flatness for radiation therapy.
    Olofsson J, Nyholm T, Ahnesjö A, Karlsson M.
    Phys Med Biol; 2007 Mar 21; 52(6):1735-46. PubMed ID: 17327659
    [Abstract] [Full Text] [Related]

  • 3. Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC).
    du Plessis FC, Leal A, Stathakis S, Xiong W, Ma CM.
    Phys Med Biol; 2006 Apr 21; 51(8):2113-29. PubMed ID: 16585849
    [Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5. Development and commissioning of a Monte Carlo photon beam model for Varian Clinac 2100EX linear accelerator.
    Mesbahi A, Reilly AJ, Thwaites DI.
    Appl Radiat Isot; 2006 Jun 21; 64(6):656-62. PubMed ID: 16455264
    [Abstract] [Full Text] [Related]

  • 6. Beam configuration and physical parameters of clinical high energy photon beam for total body irradiation (TBI).
    Ravichandran R, Binukumar JP, Davis CA, Sivakumar SS, Krishnamurthy K, Mandhari ZA, Rajan B.
    Phys Med; 2011 Jul 21; 27(3):163-8. PubMed ID: 21074467
    [Abstract] [Full Text] [Related]

  • 7. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator.
    Wiezorek T, Voigt A, Metzger N, Georg D, Schwedas M, Salz H, Wendt TG.
    Strahlenther Onkol; 2008 Feb 21; 184(2):73-9. PubMed ID: 18259698
    [Abstract] [Full Text] [Related]

  • 8. [Dosimetric characterization of a multileaf collimator].
    Stasi M, Baiotto B, Palamara F, Gabriele P, Scielzo G.
    Radiol Med; 1999 May 21; 97(5):382-8. PubMed ID: 10432971
    [Abstract] [Full Text] [Related]

  • 9. Dosimetric characteristics of unflattened 6 MV photon beams of a clinical linear accelerator: a Monte Carlo study.
    Mesbahi A.
    Appl Radiat Isot; 2007 Sep 21; 65(9):1029-36. PubMed ID: 17616465
    [Abstract] [Full Text] [Related]

  • 10. The application of the approximation method of equivalent square for magavoltage photon beams.
    Osman GE, Tsung P.
    J Med; 1980 Sep 21; 11(2-3):117-25. PubMed ID: 6774038
    [Abstract] [Full Text] [Related]

  • 11. Use of peripheral dose data from uniform dynamic multileaf collimation fields to estimate out-of-field organ dose in patients treated employing sliding window intensity-modulated radiotherapy.
    Sharma SD, Upreti RR, Deshpande DD.
    Phys Med Biol; 2006 Jun 07; 51(11):2987-95. PubMed ID: 16723779
    [Abstract] [Full Text] [Related]

  • 12. On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator.
    Tsechanski A, Krutman Y, Faermann S.
    Phys Med Biol; 2005 Dec 07; 50(23):5629-39. PubMed ID: 16306657
    [Abstract] [Full Text] [Related]

  • 13. Characterization of an add-on multileaf collimator for electron beam therapy.
    Gauer T, Sokoll J, Cremers F, Harmansa R, Luzzara M, Schmidt R.
    Phys Med Biol; 2008 Feb 21; 53(4):1071-85. PubMed ID: 18263959
    [Abstract] [Full Text] [Related]

  • 14. Measurements on the radiation protection of patients irradiated with an 18-MeV electron linear accelerator.
    Nüsslin F, Hassenstein E.
    Strahlentherapie; 1980 Feb 21; 156(2):120-4. PubMed ID: 7355412
    [Abstract] [Full Text] [Related]

  • 15. Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code.
    Panettieri V, Duch MA, Jornet N, Ginjaume M, Carrasco P, Badal A, Ortega X, Ribas M.
    Phys Med Biol; 2007 Jan 07; 52(1):303-16. PubMed ID: 17183143
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Monitoring linear accelerator output constancy using the PTW Linacheck.
    McDermott GM, Buckle AH.
    Med Dosim; 2011 Jan 07; 36(1):71-4. PubMed ID: 20346645
    [Abstract] [Full Text] [Related]

  • 18. Characteristics of the high-energy photon beam of a 25-MeV accelerator.
    Luxton G, Astrahan MA.
    Med Phys; 1988 Jan 07; 15(1):82-7. PubMed ID: 3127667
    [Abstract] [Full Text] [Related]

  • 19. X-ray beam characteristics of the Varian Clinac 6-100 linear accelerator.
    Coffey CW, Beach JL, Thompson DJ, Mendiondo M.
    Med Phys; 1980 Jan 07; 7(6):716-22. PubMed ID: 7464718
    [Abstract] [Full Text] [Related]

  • 20. Characteristics of an 18 MV photon beam from a Therac 20 Medical Linear Accelerator.
    Patterson MS, Shragge PC.
    Med Phys; 1981 Jan 07; 8(3):312-8. PubMed ID: 6798391
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 11.