These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


636 related items for PubMed ID: 11767188

  • 41. Late results of heart valve replacement with the Hancock II bioprosthesis.
    David TE, Ivanov J, Armstrong S, Feindel CM, Cohen G.
    J Thorac Cardiovasc Surg; 2001 Feb; 121(2):268-77. PubMed ID: 11174732
    [Abstract] [Full Text] [Related]

  • 42. Influence of patient-prosthesis mismatch on long-term results after aortic valve replacement with a stented bioprosthesis.
    Frapier JM, Rouvière P, Razcka F, Aymard T, Albat B, Chaptal PA.
    J Heart Valve Dis; 2002 Jul; 11(4):543-51. PubMed ID: 12150304
    [Abstract] [Full Text] [Related]

  • 43. Five-year follow up of the ATS mechanical heart valve.
    Emery RW, Krogh CC, Jones DJ, Nicoloff DM, Blake DP, Arom KV.
    J Heart Valve Dis; 2004 Mar; 13(2):231-8. PubMed ID: 15086262
    [Abstract] [Full Text] [Related]

  • 44. Single-center experience with the On-X prosthetic heart valve between 1996 and 2005.
    Tossios P, Reber D, Oustria M, Holland-Letz T, Germing A, Buchwald D, Laczkovics A.
    J Heart Valve Dis; 2007 Sep; 16(5):551-7. PubMed ID: 17944128
    [Abstract] [Full Text] [Related]

  • 45. Primary triple valve surgery for advanced rheumatic heart disease in Mainland China: a single-center experience with 871 clinical cases.
    Han QQ, Xu ZY, Zhang BR, Zou LJ, Hao JH, Huang SD.
    Eur J Cardiothorac Surg; 2007 May; 31(5):845-50. PubMed ID: 17336080
    [Abstract] [Full Text] [Related]

  • 46. Early clinical experience with the On-X prosthetic heart valve.
    Laczkovics A, Heidt M, Oelert H, Laufer G, Greve H, Pomar JL, Mohr FW, Haverich A, Birnbaum D, Regensburger D, Palatianos G, Wolner E.
    J Heart Valve Dis; 2001 Jan; 10(1):94-9. PubMed ID: 11206775
    [Abstract] [Full Text] [Related]

  • 47. Aortic and mitral valve replacement in children: is there any role for biologic and bioprosthetic substitutes?
    Alsoufi B, Manlhiot C, McCrindle BW, Canver CC, Sallehuddin A, Al-Oufi S, Joufan M, Al-Halees Z.
    Eur J Cardiothorac Surg; 2009 Jul; 36(1):84-90; discussion 90. PubMed ID: 19369085
    [Abstract] [Full Text] [Related]

  • 48. Long-term results with the Biocor-SJM stentless porcine aortic bioprosthesis.
    Vrandecic M, Fantini FA, Filho BG, de O, da C, Vrandecic E.
    J Heart Valve Dis; 2002 Jan; 11(1):47-53. PubMed ID: 11843505
    [Abstract] [Full Text] [Related]

  • 49. The CarboMedics prosthetic heart valve: experience with 1,084 implants.
    Santini F, Casali G, Viscardi F, Favaro A, Luciani GB, Pentiricci S, Lusini M, Rossi A, Mazzucco A.
    J Heart Valve Dis; 2002 Jan; 11(1):121-6; discussion 27. PubMed ID: 11843497
    [Abstract] [Full Text] [Related]

  • 50. Carpentier-Edwards supra-annular bioprosthesis in the aortic position. Has altered design affected performance?
    Wilson ES, Jamieson MP.
    J Heart Valve Dis; 1996 Jan; 5(1):40-4. PubMed ID: 8834724
    [Abstract] [Full Text] [Related]

  • 51. Clinical experience with the Carpentier-Edwards supra-annular porcine bioprosthesis implanted in the aortic position.
    Hurle A, Meseguer J, Llamas P, Casillas JA.
    J Heart Valve Dis; 1998 May; 7(3):331-5. PubMed ID: 9651848
    [Abstract] [Full Text] [Related]

  • 52. Tricuspid valve replacement subsequent to previous open heart surgery.
    Hornick P, Harris PA, Taylor KM.
    J Heart Valve Dis; 1996 Jan; 5(1):20-5. PubMed ID: 8834720
    [Abstract] [Full Text] [Related]

  • 53. Aortic valve replacement for endocarditis: determinants of early and late outcome.
    Langley SM, Alexiou C, Stafford HM, Dalrymple-Hay MJ, Haw MP, Livesey SA, Monro JL.
    J Heart Valve Dis; 2000 Sep; 9(5):697-704. PubMed ID: 11041187
    [Abstract] [Full Text] [Related]

  • 54. Short- and long-term results of triple valve surgery in the modern era.
    Alsoufi B, Rao V, Borger MA, Maganti M, Armstrong S, Feindel CM, Scully HE, David TE.
    Ann Thorac Surg; 2006 Jun; 81(6):2172-7; discussion 2177-8. PubMed ID: 16731149
    [Abstract] [Full Text] [Related]

  • 55. Very late outcomes for mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 25-year follow-up of 450 implantations.
    Bourguignon T, Bouquiaux-Stablo AL, Loardi C, Mirza A, Candolfi P, Marchand M, Aupart MR.
    J Thorac Cardiovasc Surg; 2014 Nov; 148(5):2004-2011.e1. PubMed ID: 24667021
    [Abstract] [Full Text] [Related]

  • 56. Mitroflow pericardial valve prosthesis in the aortic position: an analysis of long-term outcome and prognostic factors.
    Minami K, Boethig D, Mirow N, Kleikamp G, Koertke H, Godehardt E, Koerfer R.
    J Heart Valve Dis; 2000 Jan; 9(1):112-22. PubMed ID: 10678383
    [Abstract] [Full Text] [Related]

  • 57. CarboMedics mechanical prosthesis: performance at eight years.
    Jamieson WR, Fradet GJ, Miyagishima RT, Henderson C, Brownlee RT, Zhang J, Germann E.
    J Heart Valve Dis; 2000 Sep; 9(5):678-87. PubMed ID: 11041184
    [Abstract] [Full Text] [Related]

  • 58. Late incidence and determinants of reoperation in patients with prosthetic heart valves.
    Ruel M, Kulik A, Rubens FD, Bédard P, Masters RG, Pipe AL, Mesana TG.
    Eur J Cardiothorac Surg; 2004 Mar; 25(3):364-70. PubMed ID: 15019662
    [Abstract] [Full Text] [Related]

  • 59. Ventricular septal defect with congenital mitral valve disease: long-term results of corrective surgery.
    Agarwal S, Airan B, Chowdhury UK, Choudhary SK, Sharma R, Bhan A, Saxena A, Venugopal P.
    Indian Heart J; 2002 Mar; 54(1):67-73. PubMed ID: 11999091
    [Abstract] [Full Text] [Related]

  • 60. Excellent durability of the Hancock porcine bioprosthesis in the tricuspid position. A sixteen-year follow-up study.
    Kawachi Y, Tominaga R, Hisahara M, Nakashima A, Yasui H, Tokunaga K.
    J Thorac Cardiovasc Surg; 1992 Dec; 104(6):1561-6. PubMed ID: 1453721
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 32.