These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
145 related items for PubMed ID: 11838669
1. Selectivity of lithium electrodes: correlation with ion-lonophore complex stability constants and with interfacial exchange current densities. Mikhelson KM, Bobacka J, Ivaska A, Lewenstam A, Bochenska M. Anal Chem; 2002 Feb 01; 74(3):518-27. PubMed ID: 11838669 [Abstract] [Full Text] [Related]
2. Potentiometric estimation of the stability constants of ion-lonophore complexes in ion-selective membranes by the sandwich membrane method: theory, advantages, and limitations. Shultz MM, Stefanova OK, Mokrov SB, Mikhelson KN. Anal Chem; 2002 Feb 01; 74(3):510-7. PubMed ID: 11838668 [Abstract] [Full Text] [Related]
5. Influence of nonionic surfactants on the potentiometric response of ion-selective polymeric membrane electrodes designed for blood electrolyte measurements. Malinowska E, Meyerhoff ME. Anal Chem; 1998 Apr 15; 70(8):1477-88. PubMed ID: 9569759 [Abstract] [Full Text] [Related]
6. Determination of complex formation constants of lipophilic neutral ionophores in solvent polymeric membranes with segmented sandwich membranes. Mi Y, Bakker E. Anal Chem; 1999 Dec 01; 71(23):5279-87. PubMed ID: 10596210 [Abstract] [Full Text] [Related]
12. Polymeric membrane electrodes with improved fluoride selectivity and lifetime based on Zr(IV)- and Al(III)-tetraphenylporphyrin derivatives. Pietrzak M, Meyerhoff ME, Malinowska E. Anal Chim Acta; 2007 Jul 23; 596(2):201-9. PubMed ID: 17631098 [Abstract] [Full Text] [Related]
13. Extraction or adsorption? Voltammetric assessment of protamine transfer at ionophore-based polymeric membranes. Garada MB, Kabagambe B, Amemiya S. Anal Chem; 2015 Jul 23; 87(10):5348-55. PubMed ID: 25925866 [Abstract] [Full Text] [Related]
14. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples. Gupta VK, Singh AK, Gupta B. Anal Bioanal Chem; 2008 Apr 23; 390(8):2171-81. PubMed ID: 18335212 [Abstract] [Full Text] [Related]
16. 8-hydroxyquinoline based neutral tripodal ionophore as a copper (II) selective electrode and the effect of remote substitutents on electrode properties. Mittal SK, Kumar A, Gupta N, Kaur S, Kumar S. Anal Chim Acta; 2007 Feb 28; 585(1):161-70. PubMed ID: 17386661 [Abstract] [Full Text] [Related]
18. Transfer of Sodium Ion across Interface between Na+-Selective Electrode Membrane and Aqueous Electrolyte Solution: Can We Use Nernst Equation If Current Flows through Electrode? Keresten V, Lazarev F, Mikhelson K. Membranes (Basel); 2024 Mar 27; 14(4):. PubMed ID: 38668102 [Abstract] [Full Text] [Related]