1. Reference ranges of the dilute tissue thromboplastin inhibition and dilute Russell's viper venom tests revisited. Gerbutavicius R, Fareed J, Messmore HL, Iqbal O, Wehrmacher WH, Hoppensteadt DA, Demir M, Piccolo P, Ahmad S, Ma Q, Griniute R. Clin Appl Thromb Hemost; 2002 Jan; 8(1):51-9. PubMed ID: 11991240 [Abstract] [Full Text] [Related]
2. Reference intervals of the dilute tissue thromboplastin inhibition and dilute Russell's viper venom tests revisited. Gerbutavicius R, Fareed J, Messmore HL, Iqbal O, Hoppensteadt DA, Wehrmacher WH, Demir M, Piccolo P, Ahmad S, Ma Q, Griniute R. Clin Appl Thromb Hemost; 2002 Apr; 8(2):115-24. PubMed ID: 12121051 [Abstract] [Full Text] [Related]
5. Evaluation of four coagulation tests to detect plasma lupus anticoagulants. Saxena R, Saraya AK, Kotte VK, Singh YN, Prasad L, Malviya AN. Am J Clin Pathol; 1991 Dec; 96(6):755-8. PubMed ID: 1746492 [Abstract] [Full Text] [Related]
6. Dilute Russell's viper venom and activated partial thromboplastin time in lupus anticoagulant diagnosis: is mixing essential? Chandrashekar V. Blood Coagul Fibrinolysis; 2016 Jun; 27(4):408-11. PubMed ID: 26626041 [Abstract] [Full Text] [Related]
7. The dilution effect of equal volume mixing studies compromises confirmation of inhibition by lupus anticoagulants even when mixture specific reference ranges are applied. Moore GW, Savidge GF. Thromb Res; 2006 Jun; 118(4):523-8. PubMed ID: 16263154 [Abstract] [Full Text] [Related]
9. Heterogeneity of Russell's viper venom affects the sensitivity of the dilute Russell's viper venom time to lupus anticoagulants. Moore GW, Savidge GF. Blood Coagul Fibrinolysis; 2004 Apr; 15(3):279-82. PubMed ID: 15060428 [Abstract] [Full Text] [Related]
10. Variability of cut-off values for the detection of lupus anticoagulants: results of an international multicenter multiplatform study. Tripodi A, Chantarangkul V, Cini M, Devreese K, Dlott JS, Giacomello R, Gray E, Legnani C, Martinuzzo ME, Pradella P, Siegemund A, Subramanian S, Suchon P, Testa S. J Thromb Haemost; 2017 Jun; 15(6):1180-1190. PubMed ID: 28316135 [Abstract] [Full Text] [Related]
12. Validation of mixing test-specific cut-off in lupus anticoagulant mixing test interpretation for multiple reagents. Kumano O, Moore GW. Thromb Res; 2023 Nov; 231():39-43. PubMed ID: 37801773 [No Abstract] [Full Text] [Related]
13. Heterogeneity of lupus anticoagulant (LA) antibodies: LA activity in dilute Russell's Viper Venom Time and dilute Kaolin Clotting Time detect different populations of antibodies in patients with the "antiphospholipid" syndrome. Kandiah DA, Krilis SA. Thromb Haemost; 1998 Aug; 80(2):250-7. PubMed ID: 9716148 [Abstract] [Full Text] [Related]
15. The importance of locally derived reference ranges and standardized calculation of dilute Russell's viper venom time results in screening for lupus anticoagulant. Gardiner C, MacKie IJ, Malia RG, Jones DW, Winter M, Leeming D, Taberner DA, Machin SJ, Greaves M. Br J Haematol; 2000 Dec; 111(4):1230-5. PubMed ID: 11167766 [Abstract] [Full Text] [Related]
16. Newly developed dilute Russell's viper venom reagents for lupus anticoagulant detection with improved specificity. Moore GW, Peyrafitte M, Dunois C, Amiral J. Lupus; 2018 Jan; 27(1):95-104. PubMed ID: 28549386 [Abstract] [Full Text] [Related]
17. Comparison of test methods for the lupus anticoagulant: international survey on lupus anticoagulants-I (ISLA-1). Exner T, Triplett DA, Taberner DA, Howard MA, Harris EN. Thromb Haemost; 1990 Nov 30; 64(3):478-84. PubMed ID: 2128977 [Abstract] [Full Text] [Related]