These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
121 related items for PubMed ID: 11993480
1. Filling factor in a pulsed electron paramagnetic resonance experiment. Blank A, Levanon H. Spectrochim Acta A Mol Biomol Spectrosc; 2002 Apr; 58(6):1329-35. PubMed ID: 11993480 [Abstract] [Full Text] [Related]
3. Using nitroxide spin labels. How to obtain T1e from continuous wave electron paramagnetic resonance spectra at all rotational rates. Haas DA, Mailer C, Robinson BH. Biophys J; 1993 Mar; 64(3):594-604. PubMed ID: 8386009 [Abstract] [Full Text] [Related]
4. Filling factor of a paramagnetic sample in a rectangular cavity: theory and application. Blank A, Levanon H. Spectrochim Acta A Mol Biomol Spectrosc; 2000 Feb 01; 56A(2):363-71. PubMed ID: 10727154 [Abstract] [Full Text] [Related]
5. Comparing continuous wave progressive saturation EPR and time domain saturation recovery EPR over the entire motional range of nitroxide spin labels. Nielsen RD, Canaan S, Gladden JA, Gelb MH, Mailer C, Robinson BH. J Magn Reson; 2004 Jul 01; 169(1):129-63. PubMed ID: 15183364 [Abstract] [Full Text] [Related]
6. Evaluation and comparison of pulsed and continuous wave radiofrequency electron paramagnetic resonance techniques for in vivo detection and imaging of free radicals. Yamada K, Murugesan R, Devasahayam N, Cook JA, Mitchell JB, Subramanian S, Krishna MC. J Magn Reson; 2002 Feb 01; 154(2):287-97. PubMed ID: 11846586 [Abstract] [Full Text] [Related]
7. Studies of electron paramagnetic resonance parameters and defect structures for Ti2+ and V3+ ions in CdS crystals. Wen-Chen Z, Shao-Yi W, Hui-Ning D, Jian Z. Spectrochim Acta A Mol Biomol Spectrosc; 2002 Feb 01; 58(3):537-41. PubMed ID: 11905539 [Abstract] [Full Text] [Related]
8. In vivo imaging of a stable paramagnetic probe by pulsed-radiofrequency electron paramagnetic resonance spectroscopy. Murugesan R, Cook JA, Devasahayam N, Afeworki M, Subramanian S, Tschudin R, Larsen JA, Mitchell JB, Russo A, Krishna MC. Magn Reson Med; 1997 Sep 01; 38(3):409-14. PubMed ID: 9339442 [Abstract] [Full Text] [Related]
10. Distance measurements in the borderline region of applicability of CW EPR and DEER: a model study on a homologous series of spin-labelled peptides. Banham JE, Baker CM, Ceola S, Day IJ, Grant GH, Groenen EJ, Rodgers CT, Jeschke G, Timmel CR. J Magn Reson; 2008 Apr 01; 191(2):202-18. PubMed ID: 18280189 [Abstract] [Full Text] [Related]
11. Paramagnetic resonance of biological metal centers. Ubbink M, Worrall JA, Canters GW, Groenen EJ, Huber M. Annu Rev Biophys Biomol Struct; 2002 Apr 01; 31():393-422. PubMed ID: 11988476 [Abstract] [Full Text] [Related]
12. Mapping the Structure of Metalloproteins with RIDME. Astashkin AV. Methods Enzymol; 2015 Apr 01; 563():251-84. PubMed ID: 26478488 [Abstract] [Full Text] [Related]
13. Multifrequency electron paramagnetic resonance of irradiated L-alanine. Ghim BT, Du JL, Pfenninger S, Rinard GA, Quine RW, Eaton SS, Eaton GR. Appl Radiat Isot; 1996 Apr 01; 47(11-12):1235-9. PubMed ID: 9022182 [Abstract] [Full Text] [Related]
14. In vivo spin-label murine pharmacodynamics using low-frequency electron paramagnetic resonance imaging. Halpern HJ, Peric M, Yu C, Barth ED, Chandramouli GV, Makinen MW, Rosen GM. Biophys J; 1996 Jul 01; 71(1):403-9. PubMed ID: 8804623 [Abstract] [Full Text] [Related]
15. A high-frequency electron paramagnetic resonance spectrometer for multi-dimensional, multi-frequency, and multi-phase pulsed measurements. Cho FH, Stepanov V, Takahashi S. Rev Sci Instrum; 2014 Jul 01; 85(7):075110. PubMed ID: 25085176 [Abstract] [Full Text] [Related]
16. A new pulse width reduction technique for pulsed electron paramagnetic resonance spectroscopy. Ohba Y, Nakazawa S, Kazama S, Mizuta Y. J Magn Reson; 2008 Mar 01; 191(1):1-6. PubMed ID: 18248828 [Abstract] [Full Text] [Related]
18. Electron paramagnetic resonance and dynamic nuclear polarization of char suspensions: surface science and oximetry. Clarkson RB, Odintsov BM, Ceroke PJ, Ardenkjaer-Larsen JH, Fruianu M, Belford RL. Phys Med Biol; 1998 Jul 01; 43(7):1907-20. PubMed ID: 9703054 [Abstract] [Full Text] [Related]
19. A new EPR methodology for the study of biological systems. Eaton GR. Biophys J; 1993 May 01; 64(5):1373-4. PubMed ID: 8391866 [No Abstract] [Full Text] [Related]
20. Dynamic monitoring of localized tumor oxygenation changes using RF pulsed electron paramagnetic resonance in conscious mice. Matsumoto S, Espey MG, Utsumi H, Devasahayam N, Matsumoto K, Matsumoto A, Hirata H, Wink DA, Kuppusamy P, Subramanian S, Mitchell JB, Krishna MC. Magn Reson Med; 2008 Mar 01; 59(3):619-25. PubMed ID: 18224698 [Abstract] [Full Text] [Related] Page: [Next] [New Search]