These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
351 related items for PubMed ID: 12063448
1. Extensive primary repair of the thoracic aorta in Stanford type A acute aortic dissection by means of a synthetic vascular graft with a self-expandable stent. Ishihara H, Uchida N, Yamasaki C, Sakashita M, Kanou M. J Thorac Cardiovasc Surg; 2002 Jun; 123(6):1035-40. PubMed ID: 12063448 [Abstract] [Full Text] [Related]
2. Midterm results of extensive primary repair of the thoracic aorta by means of total arch replacement with open stent graft placement for an acute type A aortic dissection. Uchida N, Ishihara H, Shibamura H, Kyo Y, Ozawa M. J Thorac Cardiovasc Surg; 2006 Apr; 131(4):862-7. PubMed ID: 16580445 [Abstract] [Full Text] [Related]
6. Midterm results of aortic diameter outcomes after thoracic stent-graft implantation for aortic dissection: a multicenter study. Gaxotte V, Thony F, Rousseau H, Lions C, Otal P, Willoteaux S, Rodiere M, Negaiwi Z, Joffre F, Beregi JP. J Endovasc Ther; 2006 Apr; 13(2):127-38. PubMed ID: 16643066 [Abstract] [Full Text] [Related]
7. Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design. Sobocinski J, Lombardi JV, Dias NV, Berger L, Zhou Q, Jia F, Resch T, Haulon S. J Vasc Surg; 2016 May; 63(5):1216-24. PubMed ID: 26806523 [Abstract] [Full Text] [Related]
8. Acute Type A Aortic Dissection Treated Using a Tubular Stent-Graft in the Ascending Aorta and a Multibranched Stent-Graft in the Aortic Arch. Kölbel T, Detter C, Carpenter SW, Rohlffs F, von Kodolitsch Y, Wipper S, Reichenspurner H, Debus ES, Tsilimparis N. J Endovasc Ther; 2017 Feb; 24(1):75-80. PubMed ID: 27881689 [Abstract] [Full Text] [Related]
9. Treatment of acute aortic type B dissection with stent-grafts. Hausegger KA, Tiesenhausen K, Schedlbauer P, Oberwalder P, Tauss J, Rigler B. Cardiovasc Intervent Radiol; 2001 Feb; 24(5):306-12. PubMed ID: 11815835 [Abstract] [Full Text] [Related]
10. Antegrade thoracic stent grafting during repair of acute DeBakey I dissection prevents development of thoracoabdominal aortic aneurysms. Pochettino A, Brinkman WT, Moeller P, Szeto WY, Moser W, Cornelius K, Bowen FW, Woo YJ, Bavaria JE. Ann Thorac Surg; 2009 Aug; 88(2):482-9; discussion 489-90. PubMed ID: 19632398 [Abstract] [Full Text] [Related]
11. Surgery for patients with Marfan syndrome with type A dissection involving the aortic arch using total arch replacement combined with stented elephant trunk implantation: the acute versus the chronic. Sun L, Li M, Zhu J, Liu Y, Chang Q, Zheng J, Qi R. J Thorac Cardiovasc Surg; 2011 Sep; 142(3):e85-91. PubMed ID: 21377701 [Abstract] [Full Text] [Related]
12. Ascending Aorta and Hemiarch Replacement Combined With Modified Triple-Branched Stent Graft Implantation for Repair of Acute DeBakey Type I Aortic Dissection. Chen LW, Dai XF, Wu XJ, Liao DS, Hu YN, Zhang H, Dong Y. Ann Thorac Surg; 2017 Feb; 103(2):595-601. PubMed ID: 27553503 [Abstract] [Full Text] [Related]
13. Total aortic arch grafting for acute type A dissection: analysis of residual false lumen. Takahara Y, Sudo Y, Mogi K, Nakayama M, Sakurai M. Ann Thorac Surg; 2002 Feb; 73(2):450-4. PubMed ID: 11845858 [Abstract] [Full Text] [Related]
14. Repair of Stanford type A aortic dissection with ascending aorta and hemiarch replacement combined with stent-graft elephant trunk technique by using innominate cannulation. Shi E, Gu T, Yu L, Xiu Z, Zhang Z, Wang C, Fang Q. J Thorac Cardiovasc Surg; 2011 Dec; 142(6):1458-63. PubMed ID: 21458010 [Abstract] [Full Text] [Related]
15. Novel arch fenestrated stent graft for acute Stanford Type A aortic dissection with open antegrade implantation. Zhou Q, Xue Y, Cao H, Pan J, Wang Q, Fan F, Wang D. Interact Cardiovasc Thorac Surg; 2018 Mar 01; 26(3):369-375. PubMed ID: 29161440 [Abstract] [Full Text] [Related]
17. Stent-assisted balloon-induced intimal disruption and relamination of distal remaining aortic dissection after acute DeBakey type I repair. Faure EM, El Batti S, Sutter W, Bel A, Julia P, Achouh P, Alsac JM. J Thorac Cardiovasc Surg; 2019 Jun 01; 157(6):2159-2165. PubMed ID: 30501951 [Abstract] [Full Text] [Related]
19. Factors predictive of distal stent graft-induced new entry after hybrid arch elephant trunk repair with stainless steel-based device in aortic dissection. Huang CY, Weng SH, Weng CF, Chen WY, Chen IM, Hsu CP, Shih CC. J Thorac Cardiovasc Surg; 2013 Sep 01; 146(3):623-30. PubMed ID: 23040193 [Abstract] [Full Text] [Related]
20. Endovascular stent grafting of the descending thoracic aorta after arch repair in acute type A dissection. Yano H, Ishimaru S, Kawaguchi S, Obitsu Y. Ann Thorac Surg; 2002 Jan 01; 73(1):288-91. PubMed ID: 11834029 [Abstract] [Full Text] [Related] Page: [Next] [New Search]