These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
178 related items for PubMed ID: 12070517
1. Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. Oh WS, Anusavice KJ. J Prosthet Dent; 2002 May; 87(5):536-42. PubMed ID: 12070517 [Abstract] [Full Text] [Related]
2. Effect of two connector designs on the fracture resistance of all-ceramic core materials for fixed dental prostheses. Plengsombut K, Brewer JD, Monaco EA, Davis EL. J Prosthet Dent; 2009 Mar; 101(3):166-73. PubMed ID: 19231568 [Abstract] [Full Text] [Related]
3. Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design. Bahat Z, Mahmood DJ, Vult von Steyern P. Swed Dent J; 2009 Mar; 33(3):149-59. PubMed ID: 19994565 [Abstract] [Full Text] [Related]
4. Fatigue resistance of all-ceramic fixed partial dentures - Fatigue tests and finite element analysis. Heintze SD, Monreal D, Reinhardt M, Eser A, Peschke A, Reinshagen J, Rousson V. Dent Mater; 2018 Mar; 34(3):494-507. PubMed ID: 29395474 [Abstract] [Full Text] [Related]
5. Effect of connector height and retainer occlusal thickness on the fracture resistance of posterior 4-unit monolithic 5Y-TZP fixed partial dentures after thermomechanical aging. ElShamoty YK, Sadeqi HA, Baig MR. J Prosthet Dent; 2024 May; 131(5):933.e1-933.e7. PubMed ID: 38429151 [Abstract] [Full Text] [Related]
6. Influence of connector design on fracture probability of ceramic fixed-partial dentures. Oh W, Götzen N, Anusavice KJ. J Dent Res; 2002 Sep; 81(9):623-7. PubMed ID: 12202644 [Abstract] [Full Text] [Related]
7. Effect of framework design on fracture resistance in zirconia 4-unit all-ceramic fixed partial dentures. Takuma Y, Nomoto S, Sato T, Sugihara N. Bull Tokyo Dent Coll; 2013 Sep; 54(3):149-56. PubMed ID: 24334628 [Abstract] [Full Text] [Related]
8. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Int J Prosthodont; 2001 Sep; 14(3):231-8. PubMed ID: 11484570 [Abstract] [Full Text] [Related]
9. Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures. Esquivel-Upshaw JF, Young H, Jones J, Yang M, Anusavice KJ. Int J Prosthodont; 2008 Sep; 21(2):155-60. PubMed ID: 18546772 [Abstract] [Full Text] [Related]
10. Flexural strength of small connector designs of zirconia-based partial fixed dental prostheses. Hamza TA, Attia MA, El-Hossary MM, Mosleh IE, Shokry TE, Wee AG. J Prosthet Dent; 2016 Feb; 115(2):224-9. PubMed ID: 26547519 [Abstract] [Full Text] [Related]
11. Effect of connector design on fracture resistance of zirconia all-ceramic fixed partial dentures. Onodera K, Sato T, Nomoto S, Miho O, Yotsuya M. Bull Tokyo Dent Coll; 2011 Feb; 52(2):61-7. PubMed ID: 21701118 [Abstract] [Full Text] [Related]
12. Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history. Mahmood DJ, Linderoth EH, Von Steyern PV, Wennerberg A. Swed Dent J; 2013 Feb; 37(4):179-87. PubMed ID: 24620508 [Abstract] [Full Text] [Related]
13. The influence of the loading mode on the stress distribution on the connector region of metal-ceramic and all-ceramic fixed partial denture. Motta AB, Pereira LC, da Cunha AR, Duda FP. Artif Organs; 2008 Apr; 32(4):283-91. PubMed ID: 18370942 [Abstract] [Full Text] [Related]
14. Fatigue Resistance of 3-Unit CAD-CAM Ceramic Fixed Partial Dentures: An FEA Study. Bataineh K, Al Janaideh M, Abu-Naba'a LA. J Prosthodont; 2022 Dec; 31(9):806-814. PubMed ID: 35118758 [Abstract] [Full Text] [Related]
15. The in-vitro clinical failure of all-ceramic crowns and the connector area of fixed partial dentures: the influence of interfacial surface roughness. Fleming GJ, Nolan L, Harris JJ. J Dent; 2005 May; 33(5):405-12. PubMed ID: 15833396 [Abstract] [Full Text] [Related]
16. Zirconium dioxide based dental restorations. Studies on clinical performance and fracture behaviour. Larsson C. Swed Dent J Suppl; 2011 May; (213):9-84. PubMed ID: 21919311 [Abstract] [Full Text] [Related]
17. Effect of ceramic infrastructure on the failure behavior and stress distribution of fixed partial dentures. Borba M, Duan Y, Griggs JA, Cesar PF, Della Bona Á. Dent Mater; 2015 Apr; 31(4):413-22. PubMed ID: 25657090 [Abstract] [Full Text] [Related]
18. The in vitro failure of all-ceramic crowns and the connector area of fixed partial dentures using bilayered ceramic specimens: the influence of core to dentin thickness ratio. Fleming GJ, Dickens M, Thomas LJ, Harris JJ. Dent Mater; 2006 Aug; 22(8):771-7. PubMed ID: 16386291 [Abstract] [Full Text] [Related]
19. Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs. Esquivel-Upshaw JF, Anusavice KJ, Young H, Jones J, Gibbs C. Int J Prosthodont; 2004 Aug; 17(4):469-75. PubMed ID: 15382785 [Abstract] [Full Text] [Related]