These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
344 related items for PubMed ID: 12172679
1. Hyphenated techniques for the characterization and quantification of metallothionein isoforms. Prange A, Schaumlöffel D. Anal Bioanal Chem; 2002 Jul; 373(6):441-53. PubMed ID: 12172679 [Abstract] [Full Text] [Related]
2. Characterization and quantification of metallothionein isoforms by capillary electrophoresis-inductively coupled plasma-isotope-dilution mass spectrometry. Schaumlöffel D, Prange A, Marx G, Heumann KG, Brätter P. Anal Bioanal Chem; 2002 Jan; 372(1):155-63. PubMed ID: 11939186 [Abstract] [Full Text] [Related]
3. Analysis for metallothioneins using coupled techniques. Lobinski R, Chassaigne H, Szpunar J. Talanta; 1998 Jun; 46(2):271-89. PubMed ID: 18967150 [Abstract] [Full Text] [Related]
4. Species analysis of metallothionein isoforms in human brain cytosols by use of capillary electrophoresis hyphenated to inductively coupled plasma-sector field mass spectrometry. Prange A, Schaumlöffel D, Brätter P, Richarz AN, Wolf C. Fresenius J Anal Chem; 2001 Nov; 371(6):764-74. PubMed ID: 11768464 [Abstract] [Full Text] [Related]
5. Anion-exchange high performance liquid chromatography hyphenated to inductively coupled plasma-isotope dilution-time-of-flight mass spectrometry for speciation analysis of metal complexes with metallothionein isoforms in gibel carp (Carassius auratus gibelio) exposed to environmental metal pollution. Infante HG, Van Campenhout K, Blust R, Adams FC. J Chromatogr A; 2006 Jul 21; 1121(2):184-90. PubMed ID: 16678190 [Abstract] [Full Text] [Related]
6. Identification of metallothionein subisoforms in HPLC using accurate mass and online sequencing by electrospray hybrid linear ion trap-orbital ion trap mass spectrometry. Mounicou S, Ouerdane L, L'Azou B, Passagne I, Ohayon-Courtès C, Szpunar J, Lobinski R. Anal Chem; 2010 Aug 15; 82(16):6947-57. PubMed ID: 20669907 [Abstract] [Full Text] [Related]
7. Probing metal-complexes with metallothioneins by reversed phase microbore chromatography and capillary zone electrophoresis coupled with inductively coupled plasma and electrospray mass spectrometry. Połeć K, Mounicou S, Chassaigne H, Lobiński R. Cell Mol Biol (Noisy-le-grand); 2000 Mar 15; 46(2):221-35. PubMed ID: 10774916 [Abstract] [Full Text] [Related]
8. Identification and quantification of metallothionein isoforms and superoxide dismutase in spiked liver extracts using HPLC-ESI-MS offline coupling and HPLC-ICP-MS online coupling. Nischwitz V, Michalke B, Kettrup A. Anal Bioanal Chem; 2003 Jan 15; 375(1):145-56. PubMed ID: 12520451 [Abstract] [Full Text] [Related]
9. Application of CE-ICP-MS and CE-ESI-MS in metalloproteomics: challenges, developments, and limitations. Prange A, Pröfrock D. Anal Bioanal Chem; 2005 Oct 15; 383(3):372-89. PubMed ID: 16158292 [Abstract] [Full Text] [Related]
10. [Separation and identification of metallothionein isoforms and sub-isoforms by liquid chromatography]. Lu S, Shen J, Zhuang Z, Wang X. Se Pu; 2005 Mar 15; 23(2):164-7. PubMed ID: 16013560 [Abstract] [Full Text] [Related]
11. Determination of phosphorus using capillary electrophoresis and micro-high-performance liquid chromatography hyphenated with inductively coupled plasma mass spectrometry for the quantification of nucleotides. Fujii S, Inagaki K, Takatsu A, Yarita T, Chiba K. J Chromatogr A; 2009 Oct 30; 1216(44):7488-92. PubMed ID: 19497579 [Abstract] [Full Text] [Related]
12. Separation and characterization of rabbit liver apothioneins by capillary electrophoresis coupled to electrospray ionization time-of-flight mass spectrometry. Andón B, Barbosa J, Sanz-Nebot V. Electrophoresis; 2006 Sep 30; 27(18):3661-70. PubMed ID: 16927421 [Abstract] [Full Text] [Related]
13. Hyphenated techniques as tools for speciation analysis of metal-based pharmaceuticals: developments and applications. Meermann B, Sperling M. Anal Bioanal Chem; 2012 Jun 30; 403(6):1501-22. PubMed ID: 22481380 [Abstract] [Full Text] [Related]
14. [Characterization method for metallothioneins by reversed-phase liquid chromatography coupled with electrospray ionization mass spectrometry]. Huang Z, Shen J, Zhuang Z, Wang X, Lee FS. Se Pu; 2004 Nov 30; 22(6):589-94. PubMed ID: 15807108 [Abstract] [Full Text] [Related]
15. LC coupled to ESI, MALDI and ICP MS - A multiple hyphenation for metalloproteomic studies. Coufalíková K, Benešová I, Vaculovič T, Kanický V, Preisler J. Anal Chim Acta; 2017 May 22; 968():58-65. PubMed ID: 28395775 [Abstract] [Full Text] [Related]
16. Capillary electrophoresis-mass spectrometry for the analysis of intact proteins. Haselberg R, de Jong GJ, Somsen GW. J Chromatogr A; 2007 Aug 03; 1159(1-2):81-109. PubMed ID: 17560583 [Abstract] [Full Text] [Related]
17. Analysis of metallothionein by capillary electrophoresis. Ryvolova M, Adam V, Kizek R. J Chromatogr A; 2012 Feb 24; 1226():31-42. PubMed ID: 22036087 [Abstract] [Full Text] [Related]
18. Forced degradation and impurity profiling: recent trends in analytical perspectives. Jain D, Basniwal PK. J Pharm Biomed Anal; 2013 Dec 24; 86():11-35. PubMed ID: 23969330 [Abstract] [Full Text] [Related]
19. New ways in qualitative and quantitative protein analysis: nano chromatography coupled to element mass spectrometry. Schaumlöffel D. J Trace Elem Med Biol; 2007 Dec 24; 21 Suppl 1():18-22. PubMed ID: 18039489 [Abstract] [Full Text] [Related]
20. Multielement trace-element speciation in metal-biomolecules by chromatography coupled with ICP-MS. Ferrarello CN, Fernández de la Campa MR, Sanz-Medel A. Anal Bioanal Chem; 2002 Jul 24; 373(6):412-21. PubMed ID: 12172676 [Abstract] [Full Text] [Related] Page: [Next] [New Search]