These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
241 related items for PubMed ID: 12516082
1. In vitro corrosion testing of modular hip tapers. Goldberg JR, Gilbert JL. J Biomed Mater Res B Appl Biomater; 2003 Feb 15; 64(2):78-93. PubMed ID: 12516082 [Abstract] [Full Text] [Related]
2. Effect of impact assembly on the interface deformation and fretting corrosion of modular hip tapers: An in vitro study. Panagiotidou A, Cobb T, Meswania J, Skinner J, Hart A, Haddad F, Blunn G. J Orthop Res; 2018 Jan 15; 36(1):405-416. PubMed ID: 28485507 [Abstract] [Full Text] [Related]
3. Effects of Seating Load Magnitude on Incremental Cyclic Fretting Corrosion in 5°40' Mixed Alloy Modular Taper Junctions. Pierre D, Swaminathan V, Scholl LY, TenHuisen K, Gilbert JL. J Arthroplasty; 2018 Jun 15; 33(6):1953-1961. PubMed ID: 29486910 [Abstract] [Full Text] [Related]
4. Effect of impact assembly on the fretting corrosion of modular hip tapers. Mroczkowski ML, Hertzler JS, Humphrey SM, Johnson T, Blanchard CR. J Orthop Res; 2006 Feb 15; 24(2):271-9. PubMed ID: 16435360 [Abstract] [Full Text] [Related]
6. Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length. Gilbert JL, Mehta M, Pinder B. J Biomed Mater Res B Appl Biomater; 2009 Jan 15; 88(1):162-73. PubMed ID: 18613095 [Abstract] [Full Text] [Related]
7. Fretting corrosion behaviour of Ti-6Al-4V reinforced with zirconia in foetal bovine serum. Semetse L, Obadele BA, Raganya L, Geringer J, Olubambi PA. J Mech Behav Biomed Mater; 2019 Dec 15; 100():103392. PubMed ID: 31430704 [Abstract] [Full Text] [Related]
8. Insights into Imprinting: How Is the Phenomenon of Tribocorrosion at Head-Neck Taper Interfaces Related to Corrosion, Fretting, and Implant Design Parameters? Bormann T, Müller U, Gibmeier J, Mai PT, Renkawitz T, Kretzer JP. Clin Orthop Relat Res; 2022 Aug 01; 480(8):1585-1600. PubMed ID: 35383614 [Abstract] [Full Text] [Related]
9. Properties and Corrosion Performance of Self-reinforced Composite PEEK for Proposed Use as a Modular Taper Gasket. Ouellette ES, Gilbert JL. Clin Orthop Relat Res; 2016 Nov 01; 474(11):2414-2427. PubMed ID: 27146655 [Abstract] [Full Text] [Related]
10. Characterization of the fretting corrosion behavior, surface and debris from head-taper interface of two different modular hip prostheses. Dos Santos CT, Barbosa C, Monteiro MJ, Abud IC, Caminha IMV, Roesler CRM. J Mech Behav Biomed Mater; 2016 Sep 01; 62():71-82. PubMed ID: 27179766 [Abstract] [Full Text] [Related]
11. Self-reinforced poly(ether ether ketone) and polyethylene composite gaskets for prevention of mechanically-assisted corrosion in modular taper junctions: Seating, micromotion and short-term fretting corrosion. Ouellette ES, Smith SM, Gilbert JL. J Mech Behav Biomed Mater; 2021 Jul 01; 119():104454. PubMed ID: 33826987 [Abstract] [Full Text] [Related]
12. In vitro test methods for seating and fretting corrosion behavior of modular metal-on-metal acetabular tapers. Shenoy AA, Gilbert JL. J Orthop Res; 2020 May 01; 38(5):1089-1100. PubMed ID: 31803946 [Abstract] [Full Text] [Related]
13. A multicenter retrieval study of the taper interfaces of modular hip prostheses. Goldberg JR, Gilbert JL, Jacobs JJ, Bauer TW, Paprosky W, Leurgans S. Clin Orthop Relat Res; 2002 Aug 01; (401):149-61. PubMed ID: 12151892 [Abstract] [Full Text] [Related]
14. Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties. Triantafyllopoulos GK, Elpers ME, Burket JC, Esposito CI, Padgett DE, Wright TM. Clin Orthop Relat Res; 2016 Feb 01; 474(2):330-8. PubMed ID: 26208607 [Abstract] [Full Text] [Related]
15. Fretting corrosion studies of universal femoral head prostheses and cone taper spigots. Fricker DC, Shivanath R. Biomaterials; 1990 Sep 01; 11(7):495-500. PubMed ID: 2242398 [Abstract] [Full Text] [Related]
16. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. Royhman D, Pourzal R, Hall D, Lundberg HJ, Wimmer MA, Jacobs J, Hallab NJ, Mathew MT. J Mech Behav Biomed Mater; 2021 Jun 01; 118():104443. PubMed ID: 33752094 [Abstract] [Full Text] [Related]
18. Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Kurtz SM, Kocagöz SB, Hanzlik JA, Underwood RJ, Gilbert JL, MacDonald DW, Lee GC, Mont MA, Kraay MJ, Klein GR, Parvizi J, Rimnac CM. Clin Orthop Relat Res; 2013 Oct 01; 471(10):3270-82. PubMed ID: 23761174 [Abstract] [Full Text] [Related]
19. In vitro fretting crevice corrosion damage of CoCrMo alloys in phosphate buffered saline: Debris generation, chemistry and distribution. Zhu D, Liu Y, Gilbert JL. Acta Biomater; 2020 Sep 15; 114():449-459. PubMed ID: 32771589 [Abstract] [Full Text] [Related]
20. In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. Rodrigues DC, Urban RM, Jacobs JJ, Gilbert JL. J Biomed Mater Res B Appl Biomater; 2009 Jan 15; 88(1):206-19. PubMed ID: 18683224 [Abstract] [Full Text] [Related] Page: [Next] [New Search]