These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


459 related items for PubMed ID: 12528326

  • 1. Measurement of IgE antibodies using liquid allergens--an inter-method and inter-laboratory quality assessment.
    Aberer W, Kränke B.
    Wien Klin Wochenschr; 2002 Nov 30; 114(21-22):929-37. PubMed ID: 12528326
    [Abstract] [Full Text] [Related]

  • 2. Performance characteristics of a new automated enzyme immunoassay for the measurement of allergen-specific IgE. Summary of the probability outcomes comparing results of allergen skin testing to results obtained with the HYTEC system and CAP system.
    Nolte H, DuBuske LM.
    Ann Allergy Asthma Immunol; 1997 Jul 30; 79(1):27-34. PubMed ID: 9236496
    [Abstract] [Full Text] [Related]

  • 3. A new in vitro allergy diagnostic system: the Acti Tip Allerg E and Allerg Ens test system for the determination and quantitation of Total serum IgE and allergen specific IgE in human serum.
    Hubscher TT.
    Allerg Immunol (Paris); 1990 Nov 30; 22(9):360-6. PubMed ID: 2078297
    [Abstract] [Full Text] [Related]

  • 4. Performance of a fully automated in vitro allergy testing system.
    Kontis KJ, Chen A, Wang J, Nayak N, Li TM.
    Allergol Immunopathol (Madr); 1997 Nov 30; 25(2):63-6. PubMed ID: 9150834
    [Abstract] [Full Text] [Related]

  • 5. Precision and accuracy of commercial laboratories' ability to classify positive and/or negative allergen-specific IgE results.
    Szeinbach SL, Barnes JH, Sullivan TJ, Williams PB.
    Ann Allergy Asthma Immunol; 2001 Apr 30; 86(4):373-81. PubMed ID: 11345278
    [Abstract] [Full Text] [Related]

  • 6. Comparison between two automated systems to determine specific IgE: CAP and ELItest.
    Brunnée T, Seeberger A, Kleine-Tebbe J, Kunkel G.
    Clin Exp Allergy; 1996 Dec 30; 26(12):1420-7. PubMed ID: 9027443
    [Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. [Evaluation of allergen-specific IgE antibodies by a newly developed mast allergy system].
    Nakagawa T, Iwasaki E, Baba M, Matsushita T, Baba S, Ito K, Miyamoto T.
    Arerugi; 1989 Jun 30; 38(6):478-85. PubMed ID: 2686587
    [Abstract] [Full Text] [Related]

  • 9. [Quality control in the allergy laboratory--4 years "Allergy Ring Trial" in Austria].
    Aberer W, Ebner H, Horak F, Jarisch R, Klein G, Kraft D, Kremser M, Loidolt D, Ludvan M, Pohla-Gubo G.
    Wien Klin Wochenschr; 1992 Jun 30; 104(7):195-9. PubMed ID: 1381853
    [Abstract] [Full Text] [Related]

  • 10. A clinical evaluation in children of the Pharmacia ImmunoCAP system for inhalant allergens.
    Gleeson M, Cripps AW, Hensley MJ, Wlodarczyk JH, Henry RL, Clancy RL.
    Clin Exp Allergy; 1996 Jun 30; 26(6):697-702. PubMed ID: 8809427
    [Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13. ImmunoCAP Specific IgE test: an objective tool for research and routine allergy diagnosis.
    Johansson SG.
    Expert Rev Mol Diagn; 2004 May 30; 4(3):273-9. PubMed ID: 15137895
    [Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. Determination of total and specific IgE using UNICAP 100: comparative study with the CAP system.
    Cots P, Pena JM, Botey J, Eseverri JL, Marín A, Ras R.
    Allergol Immunopathol (Madr); 1998 May 30; 26(5):223-7. PubMed ID: 9885729
    [Abstract] [Full Text] [Related]

  • 16. Clinical laboratory methods for the assessment and management of human allergic diseases.
    Hamilton RG, Adkinson NF.
    Clin Lab Med; 1986 Mar 30; 6(1):117-38. PubMed ID: 3514095
    [Abstract] [Full Text] [Related]

  • 17. A comparison of intradermal testing and detection of allergen-specific immunoglobulin E in serum by enzyme-linked immunosorbent assay in horses affected with skin hypersensitivity.
    Morgan EE, Miller WH, Wagner B.
    Vet Immunol Immunopathol; 2007 Dec 15; 120(3-4):160-7. PubMed ID: 17888519
    [Abstract] [Full Text] [Related]

  • 18. A comparative study of the diagnostic characteristics of the modified RAST and Pharmacia CAP System.
    Nalebuff DJ, Fadal RG, May BC.
    Otolaryngol Head Neck Surg; 1993 Sep 15; 109(3 Pt 2):601-5. PubMed ID: 8414588
    [Abstract] [Full Text] [Related]

  • 19. Determination of multiple allergen-specific IgE by microfluidic immunoassay cartridge in clinical settings.
    Shyur SD, Jan RL, Webster JR, Chang P, Lu YJ, Wang JY.
    Pediatr Allergy Immunol; 2010 Jun 15; 21(4 Pt 1):623-33. PubMed ID: 20003065
    [Abstract] [Full Text] [Related]

  • 20. [Measurement of levels of specific IgE by the Efficient New Enzymatic Allergy (ENEA) System II (CIS bio)].
    Frémont S, Morisset M, Gérard P, Nicolas JP, Moneret-Vautrin DA.
    Allerg Immunol (Paris); 1999 Oct 15; 31(8):278-84. PubMed ID: 10572583
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 23.