These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


123 related items for PubMed ID: 12586137

  • 1. How to evaluate the influence of blood collection systems on the international sensitivity index. Protocol applied to two new evacuated tubes and eight coagulometer/thromboplastin combinations.
    Tripodi A, Chantarangkul V, Bressi C, Mannucci PM.
    Thromb Res; 2002 Oct 01; 108(1):85-9. PubMed ID: 12586137
    [Abstract] [Full Text] [Related]

  • 2. Effect of magnesium contamination in evacuated blood collection tubes on the prothrombin time test and ISI calibration using recombinant human thromboplastin and different types of coagulometer.
    van den Besselaar AM, Rutten WP, Witteveen E.
    Thromb Res; 2005 Oct 01; 115(3):239-44. PubMed ID: 15617747
    [Abstract] [Full Text] [Related]

  • 3. A comparative study of conventional versus new, magnesium-poor Vacutainer® Sodium Citrate blood collection tubes for determination of prothrombin time and INR.
    van den Besselaar AM, van Vlodrop IJ, Berendes PB, Cobbaert CM.
    Thromb Res; 2014 Jul 01; 134(1):187-91. PubMed ID: 24814970
    [Abstract] [Full Text] [Related]

  • 4. A comparison of two sodium citrate concentrations in two evacuated blood collection systems for prothrombin time and ISI determination.
    van den Besselaar AM, Chantarangkul V, Tripodi A.
    Thromb Haemost; 2000 Oct 01; 84(4):664-7. PubMed ID: 11057867
    [Abstract] [Full Text] [Related]

  • 5. Influence of blood collection systems on the prothrombin time and international sensitivity index determined with human and rabbit thromboplastin reagents.
    van den Besselaar AM, Hoekstra MM, Witteveen E, Didden JH, van der Meer FJ.
    Am J Clin Pathol; 2007 May 01; 127(5):724-9. PubMed ID: 17439830
    [Abstract] [Full Text] [Related]

  • 6. Comparative study of blood collection tubes and thromboplastin reagents for correction of INR discrepancies: a proposal for maximum allowable magnesium contamination in sodium citrate anticoagulant solutions.
    van den Besselaar AM, van Zanten AP, Brantjes HM, Elisen MG, van der Meer FJ, Poland DC, Sturk A, Leyte A, Castel A.
    Am J Clin Pathol; 2012 Aug 01; 138(2):248-54. PubMed ID: 22904137
    [Abstract] [Full Text] [Related]

  • 7. A new plastic collection tube made of polyethylene terephtalate is suitable for monitoring traditional anticoagulant therapy (oral anticoagulant, unfractionated heparin, and low molecular weight heparin).
    Toulon P, Ajzenberg N, Smahi M, Guillin MC.
    Thromb Res; 2007 Aug 01; 119(2):135-43. PubMed ID: 16426667
    [Abstract] [Full Text] [Related]

  • 8. Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-ml (pediatric) tubes.
    Chuang J, Sadler MA, Witt DM.
    Chest; 2004 Oct 01; 126(4):1262-6. PubMed ID: 15486391
    [Abstract] [Full Text] [Related]

  • 9. Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.
    Horsti J.
    Haematologica; 2001 Aug 01; 86(8):851-5. PubMed ID: 11522542
    [Abstract] [Full Text] [Related]

  • 10. Clinically significant differences in the International Normalized Ratio measured with reagents of different sensitivities. SPAF Investigators. Stroke Prevention in Atrial Fibrillation.
    Lind SE, Pearce LA, Feinberg WM, Bovill EG.
    Blood Coagul Fibrinolysis; 1999 Jul 01; 10(5):215-27. PubMed ID: 10456611
    [Abstract] [Full Text] [Related]

  • 11. Assessment of the influence of citrate concentration on the International Normalized Ratio (INR) determined with twelve reagent-instrument combinations.
    Chantarangkul V, Tripodi A, Clerici M, Negri B, Mannucci PM.
    Thromb Haemost; 1998 Aug 01; 80(2):258-62. PubMed ID: 9716149
    [Abstract] [Full Text] [Related]

  • 12. A comparison of INRs after local calibration of thromboplastin international sensitivity indexes.
    McGlasson DL.
    Clin Lab Sci; 2002 Aug 01; 15(2):91-5. PubMed ID: 12776770
    [Abstract] [Full Text] [Related]

  • 13. Usefulness of lyophilized calibration plasmas for International Normalized Ratio determination with the bovine combined thromboplastin (Thrombotest): results of a collaborative study.
    Chantarangkul V, Frontoni R, Gresele P, Oca G, Paniccia R, Pellegrini L, Tripodi A.
    Blood Coagul Fibrinolysis; 2005 Mar 01; 16(2):157-63. PubMed ID: 15741805
    [Abstract] [Full Text] [Related]

  • 14. Performance of evacuated blood collection tubes at high altitude.
    MacNutt MJ, Sheel AW.
    High Alt Med Biol; 2008 Mar 01; 9(3):235-7. PubMed ID: 18800961
    [Abstract] [Full Text] [Related]

  • 15. Local verification and assignment of mean normal prothrombin time and International Sensitivity Index values across various instruments: recent experience and outcome from North America.
    Tange JI, Grill D, Koch CD, Ybabez RJ, Krekelberg BJ, Fylling KA, Wiese CR, Baumann NA, Block DR, Karon BS, Chen D, Pruthi RK.
    Semin Thromb Hemost; 2014 Feb 01; 40(1):115-20. PubMed ID: 24381152
    [Abstract] [Full Text] [Related]

  • 16. An International Sensitivity Index (ISI) derived from patients with abnormal liver function improves agreement between INRs determined with different reagents.
    Sermon AM, Smith JM, Maclean R, Kitchen S.
    Thromb Haemost; 2010 Apr 01; 103(4):757-65. PubMed ID: 20174759
    [Abstract] [Full Text] [Related]

  • 17. Comparison between siliconized evacuated glass and plastic blood collection tubes for prothrombin time and activated partial thromboplastin time assay in normal patients, patients on oral anticoagulant therapy and patients with unfractioned heparin therapy.
    D'Angelo G, Villa C.
    Int J Lab Hematol; 2011 Apr 01; 33(2):219-25. PubMed ID: 20979595
    [Abstract] [Full Text] [Related]

  • 18. Mathematical derivative applied to international normalised ratio and analytical variations in oral anticoagulant therapy control.
    Introcaso G, Cuboni A, Ratto A, Foieni F.
    Haemostasis; 2000 Apr 01; 30(6):281-9. PubMed ID: 11356996
    [Abstract] [Full Text] [Related]

  • 19. Influence of plasma volumetric errors on the prothrombin time ratio and International Sensitivity Index.
    van den Besselaar AM, Meeuwisse-Braun J, Schaefer-van Mansfeld H, Witteveen E, van Rijn C.
    Blood Coagul Fibrinolysis; 1997 Oct 01; 8(7):431-5. PubMed ID: 9391724
    [Abstract] [Full Text] [Related]

  • 20. Standardization of coagulation tests.
    Opartkiattikul N.
    Southeast Asian J Trop Med Public Health; 1999 Oct 01; 30 Suppl 3():79-85. PubMed ID: 10926265
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.