21. Multicenter analytical evaluation of an automated immunoassay for total plasma homocysteine. Wu AH, Holtman V, Apple FS, Ricchiuti V, DiBello PM, Jacobsen D. Ann Clin Lab Sci; 2000 Apr; 30(2):185-90. PubMed ID: 10807163 [Abstract] [Full Text] [Related]
22. Analytical performance characteristics of the Abbott Architect i2000 Tacrolimus assay; comparisons with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and Abbott IMx methods. De BK, Jimenez E, De S, Sawyer JC, McMillin GA. Clin Chim Acta; 2009 Dec; 410(1-2):25-30. PubMed ID: 19751714 [Abstract] [Full Text] [Related]
23. Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods. Owen LJ, Wear JE, Keevil BG. Ann Clin Biochem; 2006 Mar; 43(Pt 2):118-23. PubMed ID: 16536913 [Abstract] [Full Text] [Related]
24. Improved method to determine succinylacetone in dried blood spots for diagnosis of tyrosinemia type 1 using UPLC-MS/MS. Al-Dirbashi OY, Rashed MS, Jacob M, Al-Ahaideb LY, Al-Amoudi M, Rahbeeni Z, Al-Sayed MM, Al-Hassnan Z, Al-Owain M, Al-Zeidan H. Biomed Chromatogr; 2008 Nov; 22(11):1181-5. PubMed ID: 18651606 [Abstract] [Full Text] [Related]
25. Clinical validation of a new blood collection tube for the accuracy of total homocysteine measurement by different methods. Bissé E, Epting T, Kögel G, Obeid R, Gempel K, Huzly D, Fuhrmann K, Rolinski B, Herrmann W, Wieland H. Clin Biochem; 2007 Jun; 40(9-10):739-43. PubMed ID: 17467680 [Abstract] [Full Text] [Related]
26. Rapid measurement of plasma acylcarnitines by liquid chromatography-tandem mass spectrometry without derivatization. Ghoshal AK, Guo T, Soukhova N, Soldin SJ. Clin Chim Acta; 2005 Aug; 358(1-2):104-12. PubMed ID: 16018880 [Abstract] [Full Text] [Related]
27. Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. Tai SS, Welch MJ. Anal Chem; 2004 Feb 15; 76(4):1008-14. PubMed ID: 14961732 [Abstract] [Full Text] [Related]
28. Evaluation of an immunoassay (Abbott-IMX Analyzer) allowing routine determination of sirolimus: comparison with LC-MS method. Bargnoux AS, Bonardet A, Chong G, Garrigue V, Deleuze S, Dupuy AM, Mourad G, Cristol JP. Transplant Proc; 2006 Sep 15; 38(7):2352-3. PubMed ID: 16980087 [Abstract] [Full Text] [Related]
32. Measurement of citrate in urine using liquid chromatography tandem mass spectrometry: comparison with an enzymatic method. Keevil BG, Owen L, Thornton S, Kavanagh J. Ann Clin Biochem; 2005 Sep 15; 42(Pt 5):357-63. PubMed ID: 16168191 [Abstract] [Full Text] [Related]
34. Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method. Dai X, Fang X, Zhang C, Xu R, Xu B. J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Oct 01; 857(2):287-95. PubMed ID: 17704012 [Abstract] [Full Text] [Related]
35. Simultaneous quantification of 17α-OH progesterone, 11-deoxycortisol, Δ4-androstenedione, cortisol and cortisone in newborn blood spots using liquid chromatography-tandem mass spectrometry. Magnisali P, Chalioti MB, Livadara T, Mataragas M, Paliatsiou S, Malamitsi-Puchner A, Moutsatsou P. J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Jun 01; 879(19):1565-72. PubMed ID: 21514253 [Abstract] [Full Text] [Related]
36. Simple method for the quantitative analysis of endogenous folate catabolites p-aminobenzoylglutamate (pABG) and its acetamido (apABG) derivative in human serum and urine by liquid chromatography-tandem mass spectrometry. Sokoro AA, Etter ML, Lepage J, Weist B, Eichhorst J, Lehotay DC. J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Feb 17; 832(1):9-16. PubMed ID: 16427369 [Abstract] [Full Text] [Related]
37. Development and validation of an LC-MS/MS method for quantification of cyclic guanosine 3',5'-monophosphate (cGMP) in clinical applications: a comparison with a EIA method. Zhang Y, Dufield D, Klover J, Li W, Szekely-Klepser G, Lepsy C, Sadagopan N. J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Feb 15; 877(5-6):513-20. PubMed ID: 19179124 [Abstract] [Full Text] [Related]
38. Comparison of the automated AxSYM and ADVIA centaur immunoassays for homocysteine determination. Haltmayer M, Mueller T, Gegenhuber A, Poelz W. Clin Lab; 2004 Feb 15; 50(3-4):175-80. PubMed ID: 15074472 [Abstract] [Full Text] [Related]