These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Direct and gradient-based average strain estimation by using weighted nearest neighbor cross-correlation peaks. Hussain MA, Abu Anas EM, Alam SK, Lee SY, Hasan MK. IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Aug; 59(8):1713-28. PubMed ID: 22899118 [Abstract] [Full Text] [Related]
5. Theoretical derivation of SNR, CNR and spatial resolution for a local adaptive strain estimator for elastography. Srinivasan S, Ophir J, Alam SK. Ultrasound Med Biol; 2004 Sep; 30(9):1185-97. PubMed ID: 15550322 [Abstract] [Full Text] [Related]
6. Performance of two dimensional displacement and strain estimation techniques using a phased array transducer. Lopata RG, Nillesen MM, Hansen HH, Gerrits IH, Thijssen JM, de Korte CL. Ultrasound Med Biol; 2009 Dec; 35(12):2031-41. PubMed ID: 19854565 [Abstract] [Full Text] [Related]
8. Multiresolution imaging in elastography. Varghese T, Bilgen M, Ophir J. IEEE Trans Ultrason Ferroelectr Freq Control; 1998 Dec; 45(1):65-75. PubMed ID: 18244159 [Abstract] [Full Text] [Related]
9. Visualizing the radial and circumferential strain distribution within vessel phantoms using synthetic-aperture ultrasound elastography. Korukonda S, Doyley MM. IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Aug; 59(8):1639-53. PubMed ID: 22899112 [Abstract] [Full Text] [Related]
10. Improvement of elastographic displacement estimation using a two-step cross-correlation method. Chen H, Shi H, Varghese T. Ultrasound Med Biol; 2007 Jan; 33(1):48-56. PubMed ID: 17189046 [Abstract] [Full Text] [Related]
11. Reduction of image noise in elastography. Céspedes I, Ophir J. Ultrason Imaging; 1993 Apr; 15(2):89-102. PubMed ID: 8346613 [Abstract] [Full Text] [Related]
14. A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues. Konofagou E, Ophir J. Ultrasound Med Biol; 1998 Oct; 24(8):1183-99. PubMed ID: 9833588 [Abstract] [Full Text] [Related]
15. Effect of temporal acquisition parameters on image quality of strain time constant elastography. Nair S, Varghese J, Chaudhry A, Righetti R. Ultrason Imaging; 2015 Apr; 37(2):87-100. PubMed ID: 24942645 [Abstract] [Full Text] [Related]
16. Phase-based direct average strain estimation for elastography. Ara SR, Mohsin F, Alam F, Rupa SA, Awwal R, Lee SY, Hasan MK. IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Nov; 60(11):2266-83. PubMed ID: 24158284 [Abstract] [Full Text] [Related]
17. Comparison of windowing effects on elastography images: Simulation, phantom and in vivo studies. Ahmed R, Arfin R, Rubel MH, Islam KK, Jia C, Metaxas D, Garra BS, Alam SK. Ultrasonics; 2016 Mar; 66():140-153. PubMed ID: 26647169 [Abstract] [Full Text] [Related]