These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


1098 related items for PubMed ID: 12701788

  • 21. Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results.
    Murakami T, Eishi K, Nakano S, Kobayashi J, Sasako Y, Isobe F, Kosakai Y, Kito Y, Kawashima Y.
    J Heart Valve Dis; 1996 Jan; 5(1):45-9. PubMed ID: 8834725
    [Abstract] [Full Text] [Related]

  • 22. Nine-year routine clinical experience of aortic valve replacement with ATS mechanical valves.
    Villemot JP, Lekehal M, Maureira P, Vanhuyse F, Sirbu C, Carteaux JP, Tran N.
    J Heart Valve Dis; 2008 Nov; 17(6):648-56. PubMed ID: 19137797
    [Abstract] [Full Text] [Related]

  • 23. Evaluation of valve-related complications in patients with Sorin Bicarbon prosthesis: a seven-year experience.
    Bortolotti U, Milano A, D'Alfonso A, Piccin C, Mecozzi G, Magagna P, Fabbri A, Mazzucco A.
    J Heart Valve Dis; 2001 Nov; 10(6):795-801. PubMed ID: 11767189
    [Abstract] [Full Text] [Related]

  • 24. Early and late results with combined mitral and aortic valve replacement.
    Matsuyoshi T, Kimura M, Tachikawa Y, Nakamura M, Iwakuma A, Morishige N, Nakamura K, Sukehiro S, Kawano Y, Anai K.
    Igaku Kenkyu; 1993 Sep; 63(3):85-94. PubMed ID: 8023654
    [Abstract] [Full Text] [Related]

  • 25. The Freedom SOLO valve for aortic valve replacement: clinical and hemodynamic results from a prospective multicenter trial.
    Beholz S, Repossini A, Livi U, Schepens M, El Gabry M, Matschke K, Trivedi U, Eckel L, Dapunt O, Zamorano JL.
    J Heart Valve Dis; 2010 Jan; 19(1):115-23. PubMed ID: 20329497
    [Abstract] [Full Text] [Related]

  • 26. Aortic valve replacement with the Sorin Pericarbon Freedom stentless prosthesis: 7 years' experience in 130 patients.
    D'Onofrio A, Auriemma S, Magagna P, Favaro A, Cannarella A, Piccin C, Bilotta M, Abbiate N, Lamascese N, Fabbri A.
    J Thorac Cardiovasc Surg; 2007 Aug; 134(2):491-5. PubMed ID: 17662795
    [Abstract] [Full Text] [Related]

  • 27.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 28.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 29. The Stentless Cryo-Life O'Brien porcine aortic valve at 10 years.
    Hvass U, Baron F, Elsebaey A, Nguyen D, Flecher E.
    J Heart Valve Dis; 2004 Nov; 13(6):977-83; discussion 983. PubMed ID: 15597593
    [Abstract] [Full Text] [Related]

  • 30. Long-term results with the Xenomedica porcine bioprosthesis in the mitral position.
    Santini F, Auriemma S, Casali G, Rossi A, Lusini M, Mazzucco A.
    J Heart Valve Dis; 2001 Nov; 10(6):789-94. PubMed ID: 11767188
    [Abstract] [Full Text] [Related]

  • 31. Chitra heart valve: results of a multicenter clinical study.
    Sankarkumar R, Bhuvaneshwar GS, Magotra R, Muralidharan S, Rajan RS, Saha D, Subba Rao KS, Valiathan MS, Radhakrishna S, Ramani AV.
    J Heart Valve Dis; 2001 Sep; 10(5):619-27. PubMed ID: 11603602
    [Abstract] [Full Text] [Related]

  • 32. Mid-term results with 1,503 CarboMedics mechanical valve implants.
    Dalrymple-Hay MJ, Pearce RK, Dawkins S, Alexiou C, Haw MP, Livesey SA, Monro JL.
    J Heart Valve Dis; 2000 May; 9(3):389-95. PubMed ID: 10888096
    [Abstract] [Full Text] [Related]

  • 33. Eleven-year single-center experience with the ATS Open Pivot Bileaflet heart valve.
    Baykut D, Grize L, Schindler C, Keil AS, Bernet F, Zerkowski HR.
    Ann Thorac Surg; 2006 Sep; 82(3):847-52. PubMed ID: 16928496
    [Abstract] [Full Text] [Related]

  • 34. Seven-year results with the St Jude Medical Silzone mechanical prosthesis.
    Jamieson WR, Fradet GJ, Abel JG, Janusz MT, Lichtenstein SV, MacNab JS, Stanford EA, Chan F.
    J Thorac Cardiovasc Surg; 2009 May; 137(5):1109-15.e2. PubMed ID: 19379975
    [Abstract] [Full Text] [Related]

  • 35. Mid-term results after Epic xenograft implantation for aortic, mitral, and double valve replacement.
    Lehmann S, Walther T, Leontjev S, Kempfert J, Rastan A, Garbade J, Borger MA, Falk V, Mohr FW.
    J Heart Valve Dis; 2007 Nov; 16(6):641-8; discussion 648. PubMed ID: 18095514
    [Abstract] [Full Text] [Related]

  • 36. Ten-year outcome with the sorin bicarbon and Baxter Mira bileaflet prostheses in the aortic position.
    Vitale N, de Feo M, Renzulli A, Gregorio R, Cappabianca G, Onorati F, de Luca L, Schinosa T, Cotrufo M.
    J Heart Valve Dis; 2004 Jul; 13(4):632-7. PubMed ID: 15311871
    [Abstract] [Full Text] [Related]

  • 37. [Replacement of the mitral and aortic valves with bioprostheses. Long-term results].
    Colombo T, Cicardi C, Peronace B, Pozzi M, Gordini V, Pellegrini A.
    G Ital Cardiol; 1985 Oct; 15(10):974-82. PubMed ID: 4092917
    [Abstract] [Full Text] [Related]

  • 38. Long-term outcome after valve replacement with the omnicarbon prosthesis.
    di Summa M, Poletti G, Brero L, Centofanti P, La Torre M, Patanè F, Raggio JM, Sanchez FG, Maroñas JM, Torregrosa S, Valera FJ, Caffarena J.
    J Heart Valve Dis; 2002 Jul; 11(4):517-23. PubMed ID: 12150300
    [Abstract] [Full Text] [Related]

  • 39. The Bicarbon heart valve prosthesis: short-term results.
    Casselman F, Herijgers P, Meyns B, Flameng W, Daenen W.
    J Heart Valve Dis; 1997 Jul; 6(4):410-5. PubMed ID: 9263874
    [Abstract] [Full Text] [Related]

  • 40. Experience with stentless aortic xenografts.
    Luciani GB, Auriemma S, Casali G, Barozzi L, Lamascese N, Mazzucco A.
    J Heart Valve Dis; 2000 Nov; 9(6):794-800. PubMed ID: 11128787
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 55.