These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Development and commissioning of a Monte Carlo photon beam model for the forthcoming clinical trials in microbeam radiation therapy. Martínez-Rovira I, Sempau J, Prezado Y. Med Phys; 2012 Jan; 39(1):119-31. PubMed ID: 22225281 [Abstract] [Full Text] [Related]
5. Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue. Bräuer-Krisch E, Serduc R, Siegbahn EA, Le Duc G, Prezado Y, Bravin A, Blattmann H, Laissue JA. Mutat Res; 2010 Jan; 704(1-3):160-6. PubMed ID: 20034592 [Abstract] [Full Text] [Related]
8. First experimental measurement of the effect of cardio-synchronous brain motion on the dose distribution during microbeam radiation therapy. Duncan M, Donzelli M, Pellicioli P, Brauer-Krisch E, Davis JA, Lerch MLF, Rosenfeld AB, Petasecca M. Med Phys; 2020 Jan; 47(1):213-222. PubMed ID: 31680274 [Abstract] [Full Text] [Related]
9. Dose profiles and x-ray energy optimization for microbeam radiation therapy by high-dose, high resolution dosimetry using Sm-doped fluoroaluminate glass plates and Monte Carlo transport simulation. Chicilo F, Hanson AL, Geisler FH, Belev G, Edgar A, Ramaswami KO, Chapman D, Kasap SO. Phys Med Biol; 2020 Apr 03; 65(7):075010. PubMed ID: 32242527 [Abstract] [Full Text] [Related]
13. Calculation of dose profiles in stereotactic synchrotron microplanar beam radiotherapy in a tissue-lung phantom. Company FZ. Australas Phys Eng Sci Med; 2007 Mar 03; 30(1):33-41. PubMed ID: 17508599 [Abstract] [Full Text] [Related]
15. Build-up and surface dose measurements on phantoms using micro-MOSFET in 6 and 10 MV x-ray beams and comparisons with Monte Carlo calculations. Xiang HF, Song JS, Chin DW, Cormack RA, Tishler RB, Makrigiorgos GM, Court LE, Chin LM. Med Phys; 2007 Apr 03; 34(4):1266-73. PubMed ID: 17500458 [Abstract] [Full Text] [Related]
16. Determination of dosimetrical quantities used in microbeam radiation therapy (MRT) with Monte Carlo simulations. Siegbahn EA, Stepanek J, Bräuer-Krisch E, Bravin A. Med Phys; 2006 Sep 03; 33(9):3248-59. PubMed ID: 17022219 [Abstract] [Full Text] [Related]
17. Microbeam radiation therapy: a Monte Carlo study of the influence of the source, multislit collimator, and beam divergence on microbeams. Nettelbeck H, Takacs GJ, Lerch ML, Rosenfeld AB. Med Phys; 2009 Feb 03; 36(2):447-56. PubMed ID: 19291983 [Abstract] [Full Text] [Related]