7. The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns. Kim Y, Yamashita J, Shotwell JL, Chong KH, Wang HL. J Prosthet Dent; 2006 Jun 01; 95(6):450-5. PubMed ID: 16765158 [Abstract] [Full Text] [Related]
8. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants. Hoyer SA, Stanford CM, Buranadham S, Fridrich T, Wagner J, Gratton D. J Prosthet Dent; 2001 Jun 01; 85(6):599-607. PubMed ID: 11404760 [Abstract] [Full Text] [Related]
9. Strength and mode of failure of single implant all-ceramic abutment restorations under static load. Tripodakis AP, Strub JR, Kappert HF, Witkowski S. Int J Prosthodont; 1995 Jun 01; 8(3):265-72. PubMed ID: 10348596 [Abstract] [Full Text] [Related]
11. The influence of veneering porcelain thickness of all-ceramic and metal ceramic crowns on failure resistance after cyclic loading. Shirakura A, Lee H, Geminiani A, Ercoli C, Feng C. J Prosthet Dent; 2009 Feb 01; 101(2):119-27. PubMed ID: 19167536 [Abstract] [Full Text] [Related]
12. Fatigue resistance of two implant/abutment joint designs. Khraisat A, Stegaroiu R, Nomura S, Miyakawa O. J Prosthet Dent; 2002 Dec 01; 88(6):604-10. PubMed ID: 12488853 [Abstract] [Full Text] [Related]
13. An in vitro load evaluation of a conical implant system with 2 abutment designs and 3 different retaining-screw alloys. Erneklint C, Odman P, Ortengren U, Karlsson S. Int J Oral Maxillofac Implants; 2006 Dec 01; 21(5):733-7. PubMed ID: 17066634 [Abstract] [Full Text] [Related]
17. Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study. Di Felice R, Rappelli G, Camaioni E, Cattani M, Meyer JM, Belser UC. Clin Oral Implants Res; 2007 Feb 01; 18(1):108-13. PubMed ID: 17224031 [Abstract] [Full Text] [Related]
18. Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments. Kolbeck C, Behr M, Rosentritt M, Handel G. Clin Oral Implants Res; 2008 Oct 01; 19(10):1049-53. PubMed ID: 18707604 [Abstract] [Full Text] [Related]
19. Fracture resistance of five different metal framework designs for metal-ceramic restorations. Ulusoy M, Toksavul S. Int J Prosthodont; 2002 Oct 01; 15(6):571-4. PubMed ID: 12475164 [Abstract] [Full Text] [Related]
20. Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns. Freitas AC, Bonfante EA, Rocha EP, Silva NR, Marotta L, Coelho PG. Eur J Oral Sci; 2011 Aug 01; 119(4):323-30. PubMed ID: 21726295 [Abstract] [Full Text] [Related] Page: [Next] [New Search]