These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


170 related items for PubMed ID: 1283507

  • 1. Significant factors in the disinfection and sterilization of flexible endoscopes.
    Vesley D, Norlien KG, Nelson B, Ott B, Streifel AJ.
    Am J Infect Control; 1992 Dec; 20(6):291-300. PubMed ID: 1283507
    [Abstract] [Full Text] [Related]

  • 2. In-hospital evaluation of 7.5% hydrogen peroxide as a disinfectant for flexible endoscopes.
    Sattar SA, Taylor YE, Paquette M, Rubino J.
    Can J Infect Control; 1996 Dec; 11(2):51-4. PubMed ID: 8868803
    [Abstract] [Full Text] [Related]

  • 3. Efficacy of electrolyzed acid water in reprocessing patient-used flexible upper endoscopes: Comparison with 2% alkaline glutaraldehyde.
    Lee JH, Rhee PL, Kim JH, Kim JJ, Paik SW, Rhee JC, Song JH, Yeom JS, Lee NY.
    J Gastroenterol Hepatol; 2004 Aug; 19(8):897-903. PubMed ID: 15242493
    [Abstract] [Full Text] [Related]

  • 4. [Synergetic germicidal effect of ultrasonic with glutaraldehyde and its application in clinical disinfection].
    Wang C, Xu X, Yu Q, Liu H.
    Wei Sheng Yan Jiu; 2004 Jan; 33(1):42-4, 48. PubMed ID: 15098476
    [Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Efficacy of routine fiberoptic endoscope cleaning and disinfection for killing Clostridium difficile.
    Hughes CE, Gebhard RL, Peterson LR, Gerding DN.
    Gastrointest Endosc; 1986 Feb; 32(1):7-9. PubMed ID: 3081401
    [Abstract] [Full Text] [Related]

  • 7. Microbial bioburden in endoscope reprocessing and an in-use evaluation of the high-level disinfection capabilities of Cidex PA.
    Vesley D, Melson J, Stanley P.
    Gastroenterol Nurs; 1999 Feb; 22(2):63-8. PubMed ID: 10382415
    [Abstract] [Full Text] [Related]

  • 8. Mycobacteria and glutaraldehyde: is high-level disinfection of endoscopes possible?
    Urayama S, Kozarek RA, Sumida S, Raltz S, Merriam L, Pethigal P.
    Gastrointest Endosc; 1996 May; 43(5):451-6. PubMed ID: 8726756
    [Abstract] [Full Text] [Related]

  • 9. Modeling microbial survival in buildup biofilm for complex medical devices.
    Alfa MJ, Howie R.
    BMC Infect Dis; 2009 May 08; 9():56. PubMed ID: 19426471
    [Abstract] [Full Text] [Related]

  • 10. Disinfection of rigid nasal endoscopes following in vitro contamination with Staphylococcus aureus, Streptococcus pneumoniae, Pseudomonas aeruginosa, and Haemophilus influenzae.
    Bradford BD, Seiberling KA, Park FE, Hiebert JC, Chang DF.
    JAMA Otolaryngol Head Neck Surg; 2013 Jun 08; 139(6):574-8. PubMed ID: 23680971
    [Abstract] [Full Text] [Related]

  • 11. Antimicrobial efficacy of endoscopic disinfection procedures: a controlled, multifactorial investigation.
    Cronmiller JR, Nelson DK, Salman G, Jackson DK, Dean RS, Hsu JJ, Kim CH.
    Gastrointest Endosc; 1999 Aug 08; 50(2):152-8. PubMed ID: 10425405
    [Abstract] [Full Text] [Related]

  • 12. Variability in reprocessing policies and procedures for flexible fiberoptic endoscopes in Massachusetts hospitals.
    Reynolds CD, Rhinehart E, Dreyer P, Goldmann DA.
    Am J Infect Control; 1992 Dec 08; 20(6):283-90. PubMed ID: 1492692
    [Abstract] [Full Text] [Related]

  • 13. Manual cleaning and disinfection of flexible endoscopes--an approach to evaluating a combined procedure.
    Knieler R.
    J Hosp Infect; 2001 Aug 08; 48 Suppl A():S84-7. PubMed ID: 11759033
    [Abstract] [Full Text] [Related]

  • 14. Efficacy of conventional endoscopic disinfection and sterilization methods against Helicobacter pylori contamination.
    Cronmiller JR, Nelson DK, Jackson DK, Kim CH.
    Helicobacter; 1999 Sep 08; 4(3):198-203. PubMed ID: 10469194
    [Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16. Contamination of endoscopes used in AIDS patients.
    Hanson PJ, Gor D, Clarke JR, Chadwick MV, Nicholson G, Shah N, Gazzard B, Jeffries DJ, Gaya H, Collins JV.
    Lancet; 1989 Jul 08; 2(8654):86-8. PubMed ID: 2567880
    [Abstract] [Full Text] [Related]

  • 17. Glutaraldehyde-resistant Mycobacterium chelonae from endoscope washer disinfectors.
    Griffiths PA, Babb JR, Bradley CR, Fraise AP.
    J Appl Microbiol; 1997 Apr 08; 82(4):519-26. PubMed ID: 9190297
    [Abstract] [Full Text] [Related]

  • 18. Deficiencies of automatic endoscopic reprocessors: a method to achieve high-grade disinfection of endoscopes.
    Ido K, Ishino Y, Ota Y, Kihira K, Taniguchi Y, Saifuku K, Satoh K, Kawamoto C, Hayashi M, Kimura K.
    Gastrointest Endosc; 1996 Nov 08; 44(5):583-6. PubMed ID: 8934166
    [Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. [HYGEA (Hygiene in gastroenterology--endoscope reprocessing): Study on quality of reprocessing flexible endoscopes in hospitals and in the practice setting].
    Bader L, Blumenstock G, Birkner B, Leiss O, Heesemann J, Riemann JF, Selbmann HK.
    Z Gastroenterol; 2002 Mar 08; 40(3):157-70. PubMed ID: 11901449
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.