These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
113 related items for PubMed ID: 12883462
1. Preliminary results with the use of an albumin-glutaraldehyde tissue adhesive in lung surgery. Potaris K, Mihos P, Gakidis I. Med Sci Monit; 2003 Jul; 9(7):PI79-83. PubMed ID: 12883462 [Abstract] [Full Text] [Related]
2. Experience with an albumin-glutaraldehyde tissue adhesive in sealing air leaks after bullectomy. Potaris K, Mihos P, Gakidis I. Heart Surg Forum; 2003 Jul; 6(5):429-33. PubMed ID: 14721826 [Abstract] [Full Text] [Related]
3. A prospective, randomized trial comparing BioGlue and Vivostat for the control of alveolar air leak. Belcher E, Dusmet M, Jordan S, Ladas G, Lim E, Goldstraw P. J Thorac Cardiovasc Surg; 2010 Jul; 140(1):32-8. PubMed ID: 20620377 [Abstract] [Full Text] [Related]
4. A prospective, randomized, controlled trial of the effectiveness of BioGlue in treating alveolar air leaks. Tansley P, Al-Mulhim F, Lim E, Ladas G, Goldstraw P. J Thorac Cardiovasc Surg; 2006 Jul; 132(1):105-12. PubMed ID: 16798309 [Abstract] [Full Text] [Related]
5. Sutureless nephron-sparing surgery: use of albumin glutaraldehyde tissue adhesive (BioGlue). Hidas G, Kastin A, Mullerad M, Shental J, Moskovitz B, Nativ O. Urology; 2006 Apr; 67(4):697-700; discussion 700. PubMed ID: 16566976 [Abstract] [Full Text] [Related]
6. Successful endobronchial seal of surgical bronchopleural fistulas using BioGlue. Ranu H, Gatheral T, Sheth A, Smith EE, Madden BP. Ann Thorac Surg; 2009 Nov; 88(5):1691-2. PubMed ID: 19853144 [Abstract] [Full Text] [Related]
7. Prospective randomized study of a protein-based tissue adhesive used as a hemostatic and structural adjunct in cardiac and vascular anastomotic repair procedures. Coselli JS, Bavaria JE, Fehrenbacher J, Stowe CL, Macheers SK, Gundry SR. J Am Coll Surg; 2003 Aug; 197(2):243-52; discussion 252-3. PubMed ID: 12892806 [Abstract] [Full Text] [Related]
8. Evaluation of the use of BioGlue in the treatment of high anal fistulas: preliminary results of a pilot study. de la Portilla F, Rada R, León E, Cisneros N, Maldonado VH, Espinosa E. Dis Colon Rectum; 2007 Feb; 50(2):218-22. PubMed ID: 17164962 [Abstract] [Full Text] [Related]
9. Bioglue: a review of the use of this new surgical adhesive in thoracic surgery. Passage J, Tam R, Windsor M, O'Brien M. ANZ J Surg; 2005 May; 75(5):315-8. PubMed ID: 15932443 [Abstract] [Full Text] [Related]
10. Release of glutaraldehyde from an albumin-glutaraldehyde tissue adhesive causes significant in vitro and in vivo toxicity. Fürst W, Banerjee A. Ann Thorac Surg; 2005 May; 79(5):1522-8; discussion 1529. PubMed ID: 15854927 [Abstract] [Full Text] [Related]
11. Closure of bronchopleural fistulas using albumin-glutaraldehyde tissue adhesive. Lin J, Iannettoni MD. Ann Thorac Surg; 2004 Jan; 77(1):326-8. PubMed ID: 14726093 [Abstract] [Full Text] [Related]
12. Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study. Moser C, Opitz I, Zhai W, Rousson V, Russi EW, Weder W, Lardinois D. J Thorac Cardiovasc Surg; 2008 Oct; 136(4):843-9. PubMed ID: 18954621 [Abstract] [Full Text] [Related]
13. Use of an electrothermal bipolar tissue sealing system in lung surgery. Santini M, Vicidomini G, Baldi A, Gallo G, Laperuta P, Busiello L, Di Marino MP, Pastore V. Eur J Cardiothorac Surg; 2006 Feb; 29(2):226-30. PubMed ID: 16376100 [Abstract] [Full Text] [Related]
14. Use of a single silastic chest drain following thoracotomy: initial evaluation. Kejriwal NK, Newman MA. ANZ J Surg; 2005 Aug; 75(8):710-2. PubMed ID: 16076338 [Abstract] [Full Text] [Related]
15. A single 24F Blake drain after wedge resection or lobectomy: a study on 100 consecutive cases. Icard P, Chautard J, Zhang X, Juanico M, Bichi S, Lerochais JP, Flais F. Eur J Cardiothorac Surg; 2006 Oct; 30(4):649-51. PubMed ID: 16934988 [Abstract] [Full Text] [Related]
17. The utility of a reusable bipolar sealing instrument, BiClamp((R)), for pulmonary resection. Sakuragi T, Okazaki Y, Mitsuoka M, Yamasaki F, Masuda M, Mori D, Satoh T, Itoh T. Eur J Cardiothorac Surg; 2008 Sep; 34(3):505-9. PubMed ID: 18585050 [Abstract] [Full Text] [Related]
18. The efficacy and side effects of gelatin-resorcinol formaldehyde-glutaraldehyde (GRFG) glue for preventing and sealing pulmonary air leakage. Nomori H, Horio H, Suemasu K. Surg Today; 2000 Sep; 30(3):244-8. PubMed ID: 10752777 [Abstract] [Full Text] [Related]
19. Experimental use of an albumin-glutaraldehyde tissue adhesive for sealing pulmonary parenchyma and bronchial anastomoses. Herget GW, Kassa M, Riede UN, Lu Y, Brethner L, Hasse J. Eur J Cardiothorac Surg; 2001 Jan; 19(1):4-9. PubMed ID: 11163552 [Abstract] [Full Text] [Related]
20. Prospective randomized study evaluating a biodegradable polymeric sealant for sealing intraoperative air leaks that occur during pulmonary resection. Allen MS, Wood DE, Hawkinson RW, Harpole DH, McKenna RJ, Walsh GL, Vallieres E, Miller DL, Nichols FC, Smythe WR, Davis RD, 3M Surgical Sealant Study Group. Ann Thorac Surg; 2004 May; 77(5):1792-801. PubMed ID: 15111188 [Abstract] [Full Text] [Related] Page: [Next] [New Search]