These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
61 related items for PubMed ID: 12955389
1. Automated method for the determination of vitamin D3 hydroxymetabolites in serum. Mata-Granados JM, Caballo-López A, Luque de Castro MD, Quesada JM. Anal Bioanal Chem; 2003 Sep; 377(2):287-92. PubMed ID: 12955389 [Abstract] [Full Text] [Related]
2. Fully automated method for the determination of 24,25(OH)2 and 25(OH) D3 hydroxyvitamins, and vitamins A and E in human serum by HPLC. Mata-Granados JM, Luque De Castro MD, Quesada JM. J Pharm Biomed Anal; 2004 May 28; 35(3):575-82. PubMed ID: 15137982 [Abstract] [Full Text] [Related]
3. Dispersive liquid-liquid microextraction for the determination of vitamins D and K in foods by liquid chromatography with diode-array and atmospheric pressure chemical ionization-mass spectrometry detection. Viñas P, Bravo-Bravo M, López-García I, Hernández-Córdoba M. Talanta; 2013 Oct 15; 115():806-13. PubMed ID: 24054666 [Abstract] [Full Text] [Related]
4. [The quantitative determination of vitamin D3 and its metabolites in plasma]. Kaune R, Harmeyer J. Biol Chem Hoppe Seyler; 1986 Nov 15; 367(11):1135-40. PubMed ID: 3028447 [Abstract] [Full Text] [Related]
6. Fully automatic method for the determination of fat soluble vitamins and vitamin D metabolites in serum. Mata-Granados JM, Quesada Gómez JM, Luque de Castro MD. Clin Chim Acta; 2009 May 15; 403(1-2):126-30. PubMed ID: 19361456 [Abstract] [Full Text] [Related]
7. Determination of vitamins A, D and E in a small volume of human plasma by a high-throughput method based on liquid chromatography/tandem mass spectrometry. Midttun Ø, Ueland PM. Rapid Commun Mass Spectrom; 2011 Jul 30; 25(14):1942-8. PubMed ID: 21698677 [Abstract] [Full Text] [Related]
8. Nonaqueous reverse phase liquid chromatographic determination of vitamin D2 in multivitamin tablets, using vitamin D3 as internal standard. Fong GW, Johnson RN, Kho BT. J Assoc Off Anal Chem; 1983 Jul 30; 66(4):939-45. PubMed ID: 6309733 [Abstract] [Full Text] [Related]
10. Differential extraction of endogenous and exogenous 25-OH-vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging. Lankes U, Elder PA, Lewis JG, George P. Ann Clin Biochem; 2015 Jan 30; 52(Pt 1):151-60. PubMed ID: 24714680 [Abstract] [Full Text] [Related]
11. Continuous cleanup/preconcentration procedure of hydroxyvitamin D3 metabolites in plasma as an alternative to batch solid-phase extraction. Ortiz-Boyer F, Fernández-Romero JM, Luque de Castro MD, Quesada JM. J Chromatogr B Biomed Sci Appl; 1997 Aug 15; 696(1):43-51. PubMed ID: 9300907 [Abstract] [Full Text] [Related]
12. Liquid chromatographic cleanup and determination of low levels of vitamin D3 in sheep plasma. Cohen H, Hidiroglou M, Keough M. J Assoc Off Anal Chem; 1984 Aug 15; 67(2):271-4. PubMed ID: 6327602 [Abstract] [Full Text] [Related]
13. High-performance liquid chromatographic-ultraviolet assay for the simultaneous quantitation of BMS-181101 and its putative hydroxy metabolites in rat and monkey plasma. Shah VR, Srinivas NR, Campbell DA, Mantha S, Duncan G, Schuster A, Whigan DW, Shyu WC. Biomed Chromatogr; 1996 Aug 15; 10(3):135-8. PubMed ID: 8792865 [Abstract] [Full Text] [Related]
15. Automated method for the determination of fat-soluble vitamins in serum. Quesada JM, Mata-Granados JM, Luque De Castro MD. J Steroid Biochem Mol Biol; 2004 May 15; 89-90(1-5):473-7. PubMed ID: 15225823 [Abstract] [Full Text] [Related]
16. Study of blood collection and sample preparation for analysis of vitamin D and its metabolites by liquid chromatography-tandem mass spectrometry. Mena-Bravo A, Priego-Capote F, Luque de Castro MD. Anal Chim Acta; 2015 Jun 16; 879():69-76. PubMed ID: 26002479 [Abstract] [Full Text] [Related]
17. Simultaneous determination of selected endocrine disrupters (pesticides, phenols and phthalates) in water by in-field solid-phase extraction (SPE) using the prototype PROFEXS followed by on-line SPE (PROSPEKT) and analysis by liquid chromatography-atmospheric pressure chemical ionisation-mass spectrometry. López-Roldán P, López de Alda MJ, Barceló D. Anal Bioanal Chem; 2004 Feb 16; 378(3):599-609. PubMed ID: 13680063 [Abstract] [Full Text] [Related]
18. Automated determination of folate catabolites in human biofluids (urine, breast milk and serum) by on-line SPE–HILIC–MS/MS. Álvarez-Sánchez B, Priego-Capote F, Mata-Granados JM, Luque de Castro MD. J Chromatogr A; 2010 Jul 09; 1217(28):4688-95. PubMed ID: 20605576 [Abstract] [Full Text] [Related]
19. Automated 96-well solid phase extraction and hydrophilic interaction liquid chromatography-tandem mass spectrometric method for the analysis of cetirizine (ZYRTEC) in human plasma--with emphasis on method ruggedness. Song Q, Junga H, Tang Y, Li AC, Addison T, McCort-Tipton M, Beato B, Naidong W. J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Jan 05; 814(1):105-14. PubMed ID: 15607714 [Abstract] [Full Text] [Related]
20. Quantitative liquid chromatographic and tandem mass spectrometric determination of vitamin D3 in human serum with derivatization: a comparison of in-tube LLE, 96-well plate LLE and in-tip SPME. Xie W, Chavez-Eng CM, Fang W, Constanzer ML, Matuszewski BK, Mullett WM, Pawliszyn J. J Chromatogr B Analyt Technol Biomed Life Sci; 2011 May 15; 879(17-18):1457-66. PubMed ID: 21459053 [Abstract] [Full Text] [Related] Page: [Next] [New Search]