These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
140 related items for PubMed ID: 1418871
1. [Clinical significance of the click intervals for the diagnosis of dysfunction of the Medtronic-Hall prosthetic valve]. Tabata T, Fukuda N, Iuchi A, Fujimoto T, Kiyoshige K, Fukuda K, Manabe K, Oki T. J Cardiol Suppl; 1992; 28():117-28; discussion 129-31. PubMed ID: 1418871 [Abstract] [Full Text] [Related]
2. Comparative phonocardiographic, echocardiographic and Doppler echocardiographic evaluation of normally functioning Medtronic Hall and Björk-Shiley mitral prosthetic valves. Fukuda N, Oki T, Tabata T, Hosoi K, Iuchi A, Manabe K, Kageji Y, Sasaki M, Hama M, Ito S. J Heart Valve Dis; 1994 May; 3(3):275-82. PubMed ID: 8087264 [Abstract] [Full Text] [Related]
3. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses]. Minardi G, Di Segni M, Boccardi L, Ferrari O, Giovannini E. G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201 [Abstract] [Full Text] [Related]
4. [Genesis and clinical significance of an apical diastolic rumble in patients with mitral Björk-Shiley valve: a Doppler echocardiographic study]. Kawano K, Fukuda N, Okumoto T, Emi S, Hosoi K, Uchida T, Kawano T, Iuchi A, Hayashi M, Oki T. J Cardiol; 1990 Feb; 20(1):147-57. PubMed ID: 2093747 [Abstract] [Full Text] [Related]
5. Sound spectral analysis of prosthetic valvular clicks for diagnosis of thrombosed Björk-Shiley tilting standard disc valve prostheses. Sato N, Miura M, Itoh T, Ohmi M, Haneda K, Mohri H, Nitta S, Tanaka M. J Thorac Cardiovasc Surg; 1993 Feb; 105(2):313-20. PubMed ID: 8429660 [Abstract] [Full Text] [Related]
6. Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping. Dittrich H, Nicod P, Hoit B, Dalton N, Sahn D. Am Heart J; 1988 Jan; 115(1 Pt 1):133-8. PubMed ID: 3336968 [Abstract] [Full Text] [Related]
9. [Limitation of Doppler echocardiography in evaluation of aortic valve prostheses]]. Geibel A, Kasper W, Fraedrich G, Konstantinides S, Schöllhorn J, Tiede N, Just H. Z Kardiol; 1993 Mar; 82(3):175-80. PubMed ID: 8475654 [Abstract] [Full Text] [Related]
10. [Clinical and hemodynamic sequelae of mitral prostheses evaluated by Doppler echocardiography]. Iwahashi K, Ota T, Sato H, Kanda H, Sugimoto T, Okada M, Nakamura K. J Cardiol; 1992 Mar; 22(4):651-9. PubMed ID: 1343631 [Abstract] [Full Text] [Related]
15. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical]. Badano L, Carratino L, De Gaetano G, Piazza R, Calisi P, Passerone G, Lucatti A. G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472 [Abstract] [Full Text] [Related]
16. Phonocardiographic findings in patients with normally functioning Ionescu-Shiley prostheses. Szkopiec RL, Desser KB, Benchimol A, Sheasby C. Am J Cardiol; 1983 Mar 15; 51(6):969-72. PubMed ID: 6829474 [Abstract] [Full Text] [Related]
17. Diagnosis of prosthetic mitral valve malfunction with combined echo-phonocardiography. Brodie BR, Grossman W, McLaurin L, Starek PJ, Craige E. Circulation; 1976 Jan 15; 53(1):93-100. PubMed ID: 1244259 [Abstract] [Full Text] [Related]
18. [Hemolysis in patients with heart valve prostheses. Comparison between Björk-Shiley and Saint-Jude Medical valves]. Ferrière M, Saussine M, Delpech S, Dinal D, Nègre G, Coulon P, Blanchet P, Latour H. Arch Mal Coeur Vaiss; 1985 Aug 15; 78(8):1243-8. PubMed ID: 3935084 [Abstract] [Full Text] [Related]
19. Recurrent pulmonary edema in a patient with a prosthetic mitral valve. Schurmans J, Ferdinande B, Keuleers S, Herijgers P, Budts W. Ann Thorac Surg; 2009 Sep 15; 88(3):996-8. PubMed ID: 19699940 [Abstract] [Full Text] [Related]