These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
288 related items for PubMed ID: 14280291
21. [Dose computation for telecobalt therapy using a computer]. Leetz HK. Rontgenpraxis; 1969 Nov; 22(11):257-65. PubMed ID: 5367995 [No Abstract] [Full Text] [Related]
22. [STUDY OF DOSE TO PROXIMITY OF AIR-TISSUE AND TISSUE-AIR INTERSPACES IN TELECOBALT THERAPY]. LEGARE JM. Acta Radiol Ther Phys Biol; 1964 Apr; 2():150-60. PubMed ID: 14162832 [No Abstract] [Full Text] [Related]
23. [THE TUMOR DOSE IN THE PRACTICE OF COBALT TELETHERAPY]. PEREIRA A. Rev Bras Cir; 1963 Jun; 45():429-32. PubMed ID: 14049795 [No Abstract] [Full Text] [Related]
24. [The use of the computer in radiotherapy. II. Construction of tables of isodose curves for cobalt teletherapy]. Milanesi R, Pasoli A, Puppini G, Cabassa N. Fracastoro; 1969 Jun; 62(6):557-70. PubMed ID: 5384268 [No Abstract] [Full Text] [Related]
25. [The use of the computer in radiotherapy. IV. Determination of the percentage distribution of the dose in cobalt teletherapy with multiple and moving fields. Presentation of 2 methods of visualization]. Milanesi R, Pasoli A, Puppini G, Cabassa N. Radiol Med; 1971 May; 57(5):337-48. PubMed ID: 5211344 [No Abstract] [Full Text] [Related]
26. [Optimal radiation planning of the 60Co depth radiotherapy. The development of estimation formulas]. Popp FA, Pemsel HK, Toll M. Strahlentherapie; 1971 Dec; 142(6):665-76. PubMed ID: 5153124 [No Abstract] [Full Text] [Related]
27. [STUDIES ON HOMOGENEITY OF DOSE DISTRIBUTION IN TUMOR. (3). COBALT-60 TELETHERAPY]. YAMASHITA N. Nihon Igaku Hoshasen Gakkai Zasshi; 1964 Jun; 24():310-7. PubMed ID: 14175053 [No Abstract] [Full Text] [Related]
28. [Surface doses and mathematical expressions for dose calculation in build-up regions for various telecobalt units and linear accelerators]. Onai Y, Trifune T, Tomaru T, Uchida I. Nihon Igaku Hoshasen Gakkai Zasshi; 1972 Dec; 32(9):735-43. PubMed ID: 4510852 [No Abstract] [Full Text] [Related]
29. [STUDIES ON TELECOBALT THERAPY MEASUREMENTS OF DOSE DISTRIBUTION IN COBALT-60 TELETHERAPY]. OKAJIMA S. Nihon Igaku Hoshasen Gakkai Zasshi; 1964 May; 24():174-9. PubMed ID: 14175347 [No Abstract] [Full Text] [Related]
30. Computer-based external beam radiotherapy planning. I. Empirical formulae for calculation of depth-doses. Worthley BW, Cooper RE. Phys Med Biol; 1967 Apr; 12(2):229-40. PubMed ID: 6033360 [No Abstract] [Full Text] [Related]
31. STUDY OF SIMPLIFIED METHODS FOR CONSTRUCTION OF COMPLETE ISODOSE DISTRIBUTIONS IN TOTATIONAL COBALT TELETHERAPY. TRUNK: HORIZONTAL 360 DEGREES CENTRAL ROTATION. SUMMERS RE, CONCANNON JP, LEONE DP. Radiology; 1964 Aug; 83():231-42. PubMed ID: 14208324 [No Abstract] [Full Text] [Related]
32. A computer method for calculating multi-field and rotational dose distributions in Co-60 teletherapy. Jayaraman S. Strahlentherapie; 1970 Sep; 140(3):283-5. PubMed ID: 5509812 [No Abstract] [Full Text] [Related]
33. DOSE DISTRIBUTION IN MOVING BEAM COBALT 60 TELETHERAPY. A GENERALISED CALCULATION METHOD. VAN DE GEIJIN J. Br J Radiol; 1963 Dec; 36():879-85. PubMed ID: 14082835 [No Abstract] [Full Text] [Related]
34. [Eccentric pendular movement in telecobalt therapy: study of relative dose distributions using electronic computation systems]. Renzi R, Maurenzig PR. Nunt Radiol; 1967 Mar; 33(3):233-48. PubMed ID: 5609879 [No Abstract] [Full Text] [Related]
35. The construction of individualised intensity modifying filters in cobalt 60 teletherapy. van de Grijn J. Br J Radiol; 1965 Nov; 38(455):865-70. PubMed ID: 5842584 [No Abstract] [Full Text] [Related]
36. [Calculation of dosage distribution in teletherapy with a digital computer. 3. Three-dimensional irradiation methods using 137Cs-gamma, 60Co-gamma and ultra-high irradiation up to 42 MV]. Fehrentz D, Kuttig H, Braun G. Strahlentherapie; 1969 Jan; 137(1):18-27. PubMed ID: 4976685 [No Abstract] [Full Text] [Related]
37. A FAST MOVING-FIELD TELECOBALT TISSUE-DOSAGE METHOD FOR ADDING MACHINE, TABULATING MACHINE, OR ELECTRONIC COMPUTER. TURNER JE, JOHNSON RM, WHITFIELD SM. Am J Roentgenol Radium Ther Nucl Med; 1965 Aug; 94():865-79. PubMed ID: 14320791 [No Abstract] [Full Text] [Related]
38. [Computation of dose distribution in a standing field for cobalt-60 teletherapy]. Schoknecht G. Strahlentherapie; 1965 Jun; 127(2):217-28. PubMed ID: 5834415 [No Abstract] [Full Text] [Related]
39. [COMPUTATION AND RECORDING OF THE DOSAGE DISTRIBUTION OF CO-60 TELETHERAPY BY MEANS OF THE IBM 1401 DATA PROCESSING SYSTEM BASED ON EXPERIMENTAL VALUES]. SCHOKNECHT G. Strahlentherapie; 1964 Sep; 125():75-90. PubMed ID: 14315454 [No Abstract] [Full Text] [Related]
40. [METHOD OF SIMPLE AND RAPID EVALUATION OF THE DISTRIBUTION OF THE DOSES IN COBALT TELETHERAPY WITH OPPOSING STATIONARY FIELDS]. CUGINI A, SOSSO A. Radiol Med; 1964 May; 50():449-60. PubMed ID: 14168273 [No Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]