These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
236 related items for PubMed ID: 1432793
1. Use of luting agents with an implant system: Part I. Breeding LC, Dixon DL, Bogacki MT, Tietge JD. J Prosthet Dent; 1992 Nov; 68(5):737-41. PubMed ID: 1432793 [Abstract] [Full Text] [Related]
2. Retentiveness of dental cements used with metallic implant components. Squier RS, Agar JR, Duncan JP, Taylor TD. Int J Oral Maxillofac Implants; 2001 Nov; 16(6):793-8. PubMed ID: 11769829 [Abstract] [Full Text] [Related]
3. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Mansour A, Ercoli C, Graser G, Tallents R, Moss M. Clin Oral Implants Res; 2002 Aug; 13(4):343-8. PubMed ID: 12175370 [Abstract] [Full Text] [Related]
7. Retentiveness of various luting agents used with implant-supported prosthesis: an in vitro study. Garg P, Pujari M, Prithviraj DR, Khare S. J Oral Implantol; 2014 Dec; 40(6):649-54. PubMed ID: 25506659 [Abstract] [Full Text] [Related]
8. Retentive strength of metal copings on prefabricated abutments with five different cements. Maeyama H, Sawase T, Jimbo R, Kamada K, Suketa N, Fukui J, Atsuta M. Clin Implant Dent Relat Res; 2005 Dec; 7(4):229-34. PubMed ID: 16336914 [Abstract] [Full Text] [Related]
9. Development of a new temporary luting agent consisting of PEMA and eugenol--residue ratio and bond strength of luting cements for abutment materials. Okada H, Ishida Y, Noguchi H, Ryukata I, Nagayama K. Dent Mater J; 2009 May; 28(3):261-6. PubMed ID: 19662723 [Abstract] [Full Text] [Related]
10. Retention strengths of five luting cements on prefabricated dowels after root canal obturation with a zinc oxide/eugenol sealer: 1. Dowel space preparation/cementation at one week after obturation. Hagge MS, Wong RD, Lindemuth JS. J Prosthodont; 2002 Sep; 11(3):168-75. PubMed ID: 12237797 [Abstract] [Full Text] [Related]
11. The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns. Kim Y, Yamashita J, Shotwell JL, Chong KH, Wang HL. J Prosthet Dent; 2006 Jun; 95(6):450-5. PubMed ID: 16765158 [Abstract] [Full Text] [Related]
12. Cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures. Michalakis KX, Pissiotis AL, Hirayama H. Int J Oral Maxillofac Implants; 2000 Jun; 15(4):545-9. PubMed ID: 10960988 [Abstract] [Full Text] [Related]
13. The effect of thermal cycling and air abrasion on cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures. Michalakis K, Pissiotis AL, Kang K, Hirayama H, Garefis PD, Petridis H. Int J Oral Maxillofac Implants; 2007 Jun; 22(4):569-74. PubMed ID: 17929517 [Abstract] [Full Text] [Related]
15. Comparison of 3 luting agents on retention of implant-supported crowns on 2 different abutments. Güncü MB, Cakan U, Canay S. Implant Dent; 2011 Oct; 20(5):349-53. PubMed ID: 21811170 [Abstract] [Full Text] [Related]
16. Retention of implant-supported zirconium oxide ceramic restorations using different luting agents. Nejatidanesh F, Savabi O, Shahtoosi M. Clin Oral Implants Res; 2013 Aug; 24 Suppl A100():20-4. PubMed ID: 22092303 [Abstract] [Full Text] [Related]
17. The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system. Clayton GH, Driscoll CF, Hondrum SO. Int J Oral Maxillofac Implants; 1997 Aug; 12(5):660-5. PubMed ID: 9337028 [Abstract] [Full Text] [Related]
18. Use of luting agents with an implant system: Part II. Dixon DL, Breeding LC, Lilly KR. J Prosthet Dent; 1992 Dec; 68(6):885-90. PubMed ID: 1494113 [Abstract] [Full Text] [Related]
19. Effects of a cementing technique in addition to luting agent on the uniaxial retention force of a single-tooth implant-supported restoration: an in vitro study. Santosa RE, Martin W, Morton D. Int J Oral Maxillofac Implants; 2010 Dec; 25(6):1145-52. PubMed ID: 21197491 [Abstract] [Full Text] [Related]
20. The effect of air abrasion of metal implant abutments on the tensile bond strength of three luting agents used to cement implant superstructures: an in vitro study. Jugdev J, Borzabadi-Farahani A, Lynch E. Int J Oral Maxillofac Implants; 2014 Dec; 29(4):784-90. PubMed ID: 25032757 [Abstract] [Full Text] [Related] Page: [Next] [New Search]