These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


249 related items for PubMed ID: 14587411

  • 1.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 2. Effect of saline pushing after contrast material injection in abdominal multidetector computed tomography with the use of different iodine concentrations.
    Tatsugami F, Matsuki M, Kani H, Tanikake M, Miyao M, Yoshikawa S, Narabayashi I.
    Acta Radiol; 2006 Mar; 47(2):192-7. PubMed ID: 16604967
    [Abstract] [Full Text] [Related]

  • 3. Usefulness of saline pushing in reduction of contrast material dose in abdominal CT: evaluation of time-density curve for the aorta, portal vein and liver.
    Tatsugami F, Matsuki M, Inada Y, Nakai G, Tanikake M, Yoshikawa S, Narabayashi I.
    Br J Radiol; 2007 Apr; 80(952):231-4. PubMed ID: 17038409
    [Abstract] [Full Text] [Related]

  • 4. Multiphase contrast-enhanced CT of the liver with a multislice CT scanner: effects of iodine concentration and delivery rate.
    Itoh S, Ikeda M, Achiwa M, Satake H, Ota T, Ishigaki T.
    Radiat Med; 2005 Feb; 23(1):61-9. PubMed ID: 15786754
    [Abstract] [Full Text] [Related]

  • 5. Multi-detector row helical CT of the liver: quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT--a prospective randomized study.
    Tsurusaki M, Sugimoto K, Fujii M, Sugimura K.
    Radiat Med; 2004 Feb; 22(4):239-45. PubMed ID: 15468944
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. Optimal iodine dose for 3-dimensional multidetector-row CT angiography of the liver.
    Ichikawa T, Motosugi U, Morisaka H, Sou H, Onohara K, Sano K, Araki T.
    Eur J Radiol; 2012 Sep; 81(9):2450-5. PubMed ID: 21708439
    [Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: a randomized study.
    Suzuki H, Oshima H, Shiraki N, Ikeya C, Shibamoto Y.
    Eur Radiol; 2004 Nov; 14(11):2099-104. PubMed ID: 15309493
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13. Application of low concentration contrast medium in spectral CT imaging for CT portal venography.
    Zhao Y, Wu Y, Zuo Z, Suo H, Zhao S, Han J, Chang X, Cheng S.
    J Xray Sci Technol; 2017 Nov; 25(1):135-143. PubMed ID: 27768006
    [Abstract] [Full Text] [Related]

  • 14. [Optimal dosage of contrast material in screening upper abdominal enhanced CT].
    Yokoyama H, Tsushima Y, Kusano S.
    Nihon Igaku Hoshasen Gakkai Zasshi; 2000 Mar; 60(3):83-6. PubMed ID: 10741114
    [Abstract] [Full Text] [Related]

  • 15. [Experiment in ultra-rapid injection of isotonic sodium chloride after injection of contrast medium: time-density analysis of the aorta and portal vein].
    Itou N, Sakurada T, Kakizaki D, Abe K.
    Nihon Igaku Hoshasen Gakkai Zasshi; 1997 Jul; 57(8):523-5. PubMed ID: 9267143
    [Abstract] [Full Text] [Related]

  • 16. Use of contrast material for spiral CT of the abdomen: comparison of hepatic enhancement and vascular attenuation for three different contrast media at two different delay times.
    Herts BR, Paushter DM, Einstein DM, Zepp R, Friedman RA, Obuchowski N.
    AJR Am J Roentgenol; 1995 Feb; 164(2):327-31. PubMed ID: 7839963
    [Abstract] [Full Text] [Related]

  • 17.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. [Septal delineation using a 20 % diluted contrast chaser bolus in coronary CT angiography: a comparison of 64-slice and dual source CT].
    Wüst W, Zunker C, May M, Anders K, Ropers D, Achenbach S, Uder M, Kuettner A.
    Rofo; 2009 Apr; 181(4):324-31. PubMed ID: 19291601
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 13.