These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Glucose sensor for flow injection analysis of serum glucose based on immobilization of glucose oxidase in titania sol-gel membrane. Yu J, Liu S, Ju H. Biosens Bioelectron; 2003 Dec 15; 19(4):401-9. PubMed ID: 14615099 [Abstract] [Full Text] [Related]
3. Phenol biosensor based on Sonogel-Carbon transducer with tyrosinase alumina sol-gel immobilization. Zejli H, Hidalgo-Hidalgo de Cisneros JL, Naranjo-Rodriguez I, Liu B, Temsamani KR, Marty JL. Anal Chim Acta; 2008 Apr 07; 612(2):198-203. PubMed ID: 18358866 [Abstract] [Full Text] [Related]
4. Development of a biosensor for endocrine disrupting compounds based on tyrosinase entrapped within a poly(thionine) film. Dempsey E, Diamond D, Collier A. Biosens Bioelectron; 2004 Sep 15; 20(2):367-77. PubMed ID: 15308243 [Abstract] [Full Text] [Related]
12. Development of a high analytical performance-tyrosinase biosensor based on a composite graphite-Teflon electrode modified with gold nanoparticles. Carralero V, Mena ML, Gonzalez-Cortés A, Yáñez-Sedeño P, Pingarrón JM. Biosens Bioelectron; 2006 Dec 15; 22(5):730-6. PubMed ID: 16569498 [Abstract] [Full Text] [Related]
13. Titania sol-gel-derived tyrosinase-based amperometric biosensor for determination of phenolic compounds in water samples. Examination of interference effects. Kochana J, Gala A, Parczewski A, Adamski J. Anal Bioanal Chem; 2008 Jun 15; 391(4):1275-81. PubMed ID: 18188544 [Abstract] [Full Text] [Related]
15. Gold nanoparticles-enhanced amperometric tyrosinase biosensor based on three-dimensional sol-gel film-modified gold electrodes. Li X, Ren T, Wang N, Ji X. Anal Sci; 2013 Jun 15; 29(4):473-7. PubMed ID: 23574677 [Abstract] [Full Text] [Related]
16. Silica sol-gel composite film as an encapsulation matrix for the construction of an amperometric tyrosinase-based biosensor. Wang B, Zhang J, Dong S. Biosens Bioelectron; 2000 Oct 15; 15(7-8):397-402. PubMed ID: 11219753 [Abstract] [Full Text] [Related]
17. Amperometric biosensor based on tyrosinase-conjugated polysaccharide hybrid film: selective determination of nanomolar neurotransmitters metabolite of 3,4-dihydroxyphenylacetic acid (DOPAC) in biological fluid. Liu A, Honma I, Zhou H. Biosens Bioelectron; 2005 Nov 15; 21(5):809-16. PubMed ID: 15886002 [Abstract] [Full Text] [Related]
18. Enzymatic determination of BPA by means of tyrosinase immobilized on different carbon carriers. Mita DG, Attanasio A, Arduini F, Diano N, Grano V, Bencivenga U, Rossi S, Amine A, Moscone D. Biosens Bioelectron; 2007 Aug 30; 23(1):60-5. PubMed ID: 17467970 [Abstract] [Full Text] [Related]