1. Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity. Bodammer N, Kaufmann J, Kanowski M, Tempelmann C. Magn Reson Med; 2004 Jan; 51(1):188-93. PubMed ID: 14705060 [Abstract] [Full Text] [Related]
2. Correction of eddy-current distortions in diffusion tensor images using the known directions and strengths of diffusion gradients. Zhuang J, Hrabe J, Kangarlu A, Xu D, Bansal R, Branch CA, Peterson BS. J Magn Reson Imaging; 2006 Nov; 24(5):1188-93. PubMed ID: 17024663 [Abstract] [Full Text] [Related]
3. Geometric distortion correction of high-resolution 3 T diffusion tensor brain images. Ardekani S, Sinha U. Magn Reson Med; 2005 Nov; 54(5):1163-71. PubMed ID: 16187289 [Abstract] [Full Text] [Related]
4. Correction for direction-dependent distortions in diffusion tensor imaging using matched magnetic field maps. Chen B, Guo H, Song AW. Neuroimage; 2006 Mar; 30(1):121-9. PubMed ID: 16242966 [Abstract] [Full Text] [Related]
5. Double-spin-echo diffusion weighting with a modified eddy current adjustment. Finsterbusch J. Magn Reson Imaging; 2010 Apr; 28(3):434-40. PubMed ID: 20071120 [Abstract] [Full Text] [Related]
6. Diffeomorphic susceptibility artifact correction of diffusion-weighted magnetic resonance images. Ruthotto L, Kugel H, Olesch J, Fischer B, Modersitzki J, Burger M, Wolters CH. Phys Med Biol; 2012 Sep 21; 57(18):5715-31. PubMed ID: 22941943 [Abstract] [Full Text] [Related]
7. Correction of eddy current distortions in high angular resolution diffusion imaging. Zhuang J, Lu ZL, Vidal CB, Damasio H. J Magn Reson Imaging; 2013 Jun 21; 37(6):1460-7. PubMed ID: 23172807 [Abstract] [Full Text] [Related]
9. Mapping eddy current induced fields for the correction of diffusion-weighted echo planar images. Horsfield MA. Magn Reson Imaging; 1999 Nov 21; 17(9):1335-45. PubMed ID: 10576719 [Abstract] [Full Text] [Related]
10. Evaluation of eddy current distortion and field inhomogeneity distortion corrections in MR diffusion imaging using log-demons DIR method. Arsenault T, Yin FF, Chino J, Craciunescu O, Chang JZ. Phys Med Biol; 2021 Jan 29; 66(3):035021. PubMed ID: 33202395 [Abstract] [Full Text] [Related]
11. Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI. Rohde GK, Barnett AS, Basser PJ, Marenco S, Pierpaoli C. Magn Reson Med; 2004 Jan 29; 51(1):103-14. PubMed ID: 14705050 [Abstract] [Full Text] [Related]
12. Prospective and retrospective high order eddy current mitigation for diffusion weighted echo planar imaging. Xu D, Maier JK, King KF, Collick BD, Wu G, Peters RD, Hinks RS. Magn Reson Med; 2013 Nov 29; 70(5):1293-305. PubMed ID: 23325564 [Abstract] [Full Text] [Related]
13. Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation. Bastin ME. Magn Reson Imaging; 1999 Sep 29; 17(7):1011-24. PubMed ID: 10463652 [Abstract] [Full Text] [Related]
14. Efficacy of distortion correction on diffusion imaging: comparison of FSL eddy and eddy_correct using 30 and 60 directions diffusion encoding. Yamada H, Abe O, Shizukuishi T, Kikuta J, Shinozaki T, Dezawa K, Nagano A, Matsuda M, Haradome H, Imamura Y. PLoS One; 2014 Sep 29; 9(11):e112411. PubMed ID: 25405472 [Abstract] [Full Text] [Related]
15. Correcting eddy current and motion effects by affine whole-brain registrations: evaluation of three-dimensional distortions and comparison with slicewise correction. Mohammadi S, Möller HE, Kugel H, Müller DK, Deppe M. Magn Reson Med; 2010 Oct 29; 64(4):1047-56. PubMed ID: 20574966 [Abstract] [Full Text] [Related]
16. Phantom-based evaluation of geometric distortions in functional magnetic resonance and diffusion tensor imaging. Mattila S, Renvall V, Hiltunen J, Kirven D, Sepponen R, Hari R, Tarkiainen A. Magn Reson Med; 2007 Apr 29; 57(4):754-63. PubMed ID: 17390354 [Abstract] [Full Text] [Related]
17. Characterization and correction of diffusion gradient-induced eddy currents in second-order motion-compensated echo-planar and spiral cardiac DTI. van Gorkum RJH, Guenthner C, Koethe A, Stoeck CT, Kozerke S. Magn Reson Med; 2022 Dec 29; 88(6):2378-2394. PubMed ID: 35916545 [Abstract] [Full Text] [Related]
18. Integrated SENSE DTI with correction of susceptibility- and eddy current-induced geometric distortions. Truong TK, Chen B, Song AW. Neuroimage; 2008 Mar 01; 40(1):53-8. PubMed ID: 18187344 [Abstract] [Full Text] [Related]
19. Characterization and correction of time-varying eddy currents for diffusion MRI. Valsamis JJ, Dubovan PI, Baron CA. Magn Reson Med; 2022 May 01; 87(5):2209-2223. PubMed ID: 34894640 [Abstract] [Full Text] [Related]
20. Characterization of and correction for eddy current artifacts in echo planar diffusion imaging. Jezzard P, Barnett AS, Pierpaoli C. Magn Reson Med; 1998 May 01; 39(5):801-12. PubMed ID: 9581612 [Abstract] [Full Text] [Related] Page: [Next] [New Search]