These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
115 related items for PubMed ID: 14973870
21. High Failure Rate of Modular Exchange With a Specific Design of a Constrained Liner in High-Risk Patients Undergoing Revision Total Hip Arthroplasty. Chalmers BP, Arsoy D, Sierra RJ, Lewallen DG, Trousdale RT. J Arthroplasty; 2016 Sep; 31(9):1963-9. PubMed ID: 26975601 [Abstract] [Full Text] [Related]
22. Failure of a constrained acetabular liner without reinforcement ring disruption. Arthur JA, Amanatullah DF, Kennedy GD, Di Cesare PE. Am J Orthop (Belle Mead NJ); 2013 Dec; 42(12):566-8. PubMed ID: 24471147 [Abstract] [Full Text] [Related]
24. Dual-mobility or Constrained Liners Are More Effective Than Preoperative Bariatric Surgery in Prevention of THA Dislocation. Hernigou P, Trousselier M, Roubineau F, Bouthors C, Flouzat Lachaniette CH. Clin Orthop Relat Res; 2016 Oct; 474(10):2202-10. PubMed ID: 27130648 [Abstract] [Full Text] [Related]
25. Severe damage of the femoral head after dislocation and difficult reduction maneuvers after total hip arthroplasty. Schuh A, Mittelmeier W, Zeiler G, Behrend D, Kircher J, Bader R. Arch Orthop Trauma Surg; 2006 Mar; 126(2):134-7. PubMed ID: 16402198 [Abstract] [Full Text] [Related]
26. Failure of constrained acetabular liner without metal ring disruption. Sathappan SS, Ginat D, Teicher M, Di Cesare PE. Orthopedics; 2008 Mar; 31(3):275. PubMed ID: 19292234 [Abstract] [Full Text] [Related]
27. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors. Hernigou P, Roussignol X, Delambre J, Poignard A, Flouzat-Lachaniette CH. Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482 [Abstract] [Full Text] [Related]
28. Short-term results with a constrained acetabular liner in patients at high risk of dislocation after primary total hip arthroplasty. Gill K, Whitehouse SL, Hubble MJ, Wilson MJ. Hip Int; 2016 Nov 10; 26(6):580-584. PubMed ID: 27739571 [Abstract] [Full Text] [Related]
29. Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement. Ayers DC, Greene M, Snyder B, Aubin M, Drew J, Bragdon C. J Bone Joint Surg Am; 2015 Apr 15; 97(8):627-34. PubMed ID: 25878306 [Abstract] [Full Text] [Related]
30. Large-head metal-on-metal total hip arthroplasty using the Durom acetabular component at minimum 1-year interval. Illgen RL, Heiner JP, Squire MW, Conrad DN. J Arthroplasty; 2010 Sep 15; 25(6 Suppl):26-30. PubMed ID: 20570096 [Abstract] [Full Text] [Related]
31. Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement. Ancelin D, Reina N, Cavaignac E, Delclaux S, Chiron P. Orthop Traumatol Surg Res; 2016 Dec 15; 102(8):1029-1034. PubMed ID: 28341264 [Abstract] [Full Text] [Related]
32. Constrained Acetabular Components Used in Revision Total Hip Arthroplasty: A Registry Analysis. Lewis PL, Graves SE, de Steiger RN, Cuthbert AR. J Arthroplasty; 2017 Oct 15; 32(10):3102-3107. PubMed ID: 28576624 [Abstract] [Full Text] [Related]
33. Freedom Constrained Liner for the Treatment and Prevention of Dislocation in Total Hip Arthroplasty. Karvonen M, Karvonen H, Seppänen M, Liukas A, Koivisto M, Mäkelä KT. Scand J Surg; 2017 Jun 15; 106(2):165-172. PubMed ID: 27456021 [Abstract] [Full Text] [Related]
34. Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty. Nam D, Barrack T, Johnson SR, Nunley RM, Barrack RL. Clin Orthop Relat Res; 2016 Oct 15; 474(10):2115-22. PubMed ID: 26911973 [Abstract] [Full Text] [Related]
35. An unusual mode of failure of a tripolar constrained acetabular liner: a case report. Banks LN, McElwain JP. Arch Orthop Trauma Surg; 2010 Apr 15; 130(4):503-5. PubMed ID: 19629505 [Abstract] [Full Text] [Related]
38. Outcomes at least 10 years after cemented PF® (Zimmer) total hip arthroplasty: 83 cases. Aubault M, Druon J, Le Nail L, Rosset P. Orthop Traumatol Surg Res; 2013 Jun 15; 99(4 Suppl):S235-9. PubMed ID: 23628004 [Abstract] [Full Text] [Related]
39. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA? Baek SH, Kim WK, Kim JY, Kim SY. Clin Orthop Relat Res; 2015 Dec 15; 473(12):3796-802. PubMed ID: 26126991 [Abstract] [Full Text] [Related]
40. Femoral revision in hip resurfacing compared with large-bearing metal-on-metal hip arthroplasty. Garrett SJ, Bolland BJ, Yates PJ, Gardner EM, Latham JM. J Arthroplasty; 2011 Dec 15; 26(8):1214-8. PubMed ID: 21414749 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]