These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


355 related items for PubMed ID: 14977345

  • 1. Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis.
    Marx G, Cope T, McCrossan L, Swaraj S, Cowan C, Mostafa SM, Wenstone R, Leuwer M.
    Eur J Anaesthesiol; 2004 Feb; 21(2):132-8. PubMed ID: 14977345
    [Abstract] [Full Text] [Related]

  • 2. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients.
    Wiesenack C, Fiegl C, Keyser A, Prasser C, Keyl C.
    Eur J Anaesthesiol; 2005 Sep; 22(9):658-65. PubMed ID: 16163911
    [Abstract] [Full Text] [Related]

  • 3. [Stroke volume and pulse pressure variation are good predictors of fluid responsiveness in sepsis patients].
    Drvar Z, Pavlek M, Drvar V, Tomasević B, Baronica R, Perić M.
    Acta Med Croatica; 2013 Dec; 67(5):407-14. PubMed ID: 24979881
    [Abstract] [Full Text] [Related]

  • 4. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery.
    Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE.
    Intensive Care Med; 2002 Apr; 28(4):392-8. PubMed ID: 11967591
    [Abstract] [Full Text] [Related]

  • 5. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function.
    Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, Goetz AE.
    Crit Care Med; 2003 May; 31(5):1399-404. PubMed ID: 12771609
    [Abstract] [Full Text] [Related]

  • 6. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients.
    Reuter DA, Bayerlein J, Goepfert MS, Weis FC, Kilger E, Lamm P, Goetz AE.
    Intensive Care Med; 2003 Mar; 29(3):476-80. PubMed ID: 12579420
    [Abstract] [Full Text] [Related]

  • 7. Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.
    Huang CC, Fu JY, Hu HC, Kao KC, Chen NH, Hsieh MJ, Tsai YH.
    Crit Care Med; 2008 Oct; 36(10):2810-6. PubMed ID: 18766099
    [Abstract] [Full Text] [Related]

  • 8. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension.
    Tavernier B, Makhotine O, Lebuffe G, Dupont J, Scherpereel P.
    Anesthesiology; 1998 Dec; 89(6):1313-21. PubMed ID: 9856704
    [Abstract] [Full Text] [Related]

  • 9. Arm occlusion pressure is a useful predictor of an increase in cardiac output after fluid loading following cardiac surgery.
    Geerts BF, Maas J, de Wilde RB, Aarts LP, Jansen JR.
    Eur J Anaesthesiol; 2011 Nov; 28(11):802-6. PubMed ID: 21799416
    [Abstract] [Full Text] [Related]

  • 10. Myocardial performance index during rapidly changing loading conditions: impact of different tidal ventilation.
    Renner J, Cavus E, Gruenewald M, Steinfath M, Scholz J, Lutter G, Steffen M, Bein B.
    Eur J Anaesthesiol; 2008 Mar; 25(3):217-23. PubMed ID: 18028576
    [Abstract] [Full Text] [Related]

  • 11. [An evaluation of stroke volume variation as a predictor of fluid responsiveness in mechanically ventilated elderly patients with severe sepsis].
    Yu YH, Dai HW, Yan ML, Gong SJ, Cai GL, Zhang ZC, Chen J, Yan J.
    Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2009 Aug; 21(8):463-5. PubMed ID: 19695166
    [Abstract] [Full Text] [Related]

  • 12. Comparison of an automated respiratory systolic variation test with dynamic preload indicators to predict fluid responsiveness after major surgery.
    Trepte CJ, Eichhorn V, Haas SA, Stahl K, Schmid F, Nitzschke R, Goetz AE, Reuter DA.
    Br J Anaesth; 2013 Nov; 111(5):736-42. PubMed ID: 23811425
    [Abstract] [Full Text] [Related]

  • 13. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis.
    Préau S, Saulnier F, Dewavrin F, Durocher A, Chagnon JL.
    Crit Care Med; 2010 Mar; 38(3):819-25. PubMed ID: 20016380
    [Abstract] [Full Text] [Related]

  • 14. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge.
    Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, Teboul JL.
    Crit Care Med; 2007 Jan; 35(1):64-8. PubMed ID: 17080001
    [Abstract] [Full Text] [Related]

  • 15. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery.
    Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A.
    Anesth Analg; 2001 Apr; 92(4):984-9. PubMed ID: 11273937
    [Abstract] [Full Text] [Related]

  • 16. Effects of changes in blood pressure and airway pressures on parameters of fluid responsiveness.
    Sakka SG, Becher L, Kozieras J, van Hout N.
    Eur J Anaesthesiol; 2009 Apr; 26(4):322-7. PubMed ID: 19401662
    [Abstract] [Full Text] [Related]

  • 17. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock.
    Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL.
    Chest; 2003 Nov; 124(5):1900-8. PubMed ID: 14605066
    [Abstract] [Full Text] [Related]

  • 18. Cardiac filling volumes versus pressures for predicting fluid responsiveness after cardiovascular surgery: the role of systolic cardiac function.
    Trof RJ, Danad I, Reilingh MW, Breukers RM, Groeneveld AB.
    Crit Care; 2011 Nov; 15(1):R73. PubMed ID: 21352541
    [Abstract] [Full Text] [Related]

  • 19. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects.
    Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, Neumann A, Ali A, Cheang M, Kavinsky C, Parrillo JE.
    Crit Care Med; 2004 Mar; 32(3):691-9. PubMed ID: 15090949
    [Abstract] [Full Text] [Related]

  • 20. Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery.
    Zimmermann M, Feibicke T, Keyl C, Prasser C, Moritz S, Graf BM, Wiesenack C.
    Eur J Anaesthesiol; 2010 Jun; 27(6):555-61. PubMed ID: 20035228
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 18.