These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


152 related items for PubMed ID: 15026278

  • 1. Analytical and clinical evaluation of the Bayer ADVIA Centaur homocysteine assay.
    Tewari PC, Zhang B, Bluestein BI.
    Clin Chim Acta; 2004 Apr; 342(1-2):171-8. PubMed ID: 15026278
    [Abstract] [Full Text] [Related]

  • 2. Comparison of the automated AxSYM and ADVIA centaur immunoassays for homocysteine determination.
    Haltmayer M, Mueller T, Gegenhuber A, Poelz W.
    Clin Lab; 2004 Apr; 50(3-4):175-80. PubMed ID: 15074472
    [Abstract] [Full Text] [Related]

  • 3. Evaluation of Advia Centaur automated chemiluminescence immunoassay for determining total homocysteine in plasma.
    Demuth K, Ducros V, Michelsohn S, Paul JL.
    Clin Chim Acta; 2004 Nov; 349(1-2):113-20. PubMed ID: 15469863
    [Abstract] [Full Text] [Related]

  • 4. Multicenter analytical evaluation of an automated immunoassay for total plasma homocysteine.
    Wu AH, Holtman V, Apple FS, Ricchiuti V, DiBello PM, Jacobsen D.
    Ann Clin Lab Sci; 2000 Apr; 30(2):185-90. PubMed ID: 10807163
    [Abstract] [Full Text] [Related]

  • 5. Performance evaluation of a specific IgE assay developed for the ADVIA centaur immunoassay system.
    Petersen AB, Gudmann P, Milvang-Grønager P, Mørkeberg R, Bøgestrand S, Linneberg A, Johansen N.
    Clin Biochem; 2004 Oct; 37(10):882-92. PubMed ID: 15369719
    [Abstract] [Full Text] [Related]

  • 6. European performance evaluations of the ADVIA Centaur infectious disease assays: requirements for performance evaluation according to the European directive on in vitro diagnostics.
    Dati F, Denoyel G, van Helden J.
    J Clin Virol; 2004 Apr; 30 Suppl 1():S6-10. PubMed ID: 15062761
    [Abstract] [Full Text] [Related]

  • 7. Performance characteristics of a recombinant enzymatic cycling assay for quantification of total homocysteine in serum or plasma.
    Roberts RF, Roberts WL.
    Clin Chim Acta; 2004 Jun; 344(1-2):95-9. PubMed ID: 15149876
    [Abstract] [Full Text] [Related]

  • 8. Performance characteristics of six homocysteine assays.
    La'ulu SL, Rawlins ML, Pfeiffer CM, Zhang M, Roberts WL.
    Am J Clin Pathol; 2008 Dec; 130(6):969-75. PubMed ID: 19019776
    [Abstract] [Full Text] [Related]

  • 9. Evaluation of an enzymatic homocysteine assay for the Hitachi series chemistry analyzer.
    Kellogg MD, Parker R, Ricupero A, Rifai N.
    Clin Chim Acta; 2005 Apr; 354(1-2):117-22. PubMed ID: 15748607
    [Abstract] [Full Text] [Related]

  • 10. Performance of a new hepatitis C assay on the Bayer ADVIA Centaur Immunoassay System.
    Denoyel G, van Helden J, Bauer R, Preisel-Simmons B.
    Clin Lab; 2004 Apr; 50(1-2):75-82. PubMed ID: 15000223
    [Abstract] [Full Text] [Related]

  • 11. Validation of an enzyme immunoassay for the determination of total homocysteine in plasma.
    Quintana I, Freeman D, Galarza C, Murua A, Spence JD, Kordich L.
    Blood Coagul Fibrinolysis; 2000 Apr; 11(3):235-8. PubMed ID: 10870802
    [Abstract] [Full Text] [Related]

  • 12. Total plasma homocysteine in Bulgarian population measured by high-performance liquid chromatography with fluorescence detection--comparison with fluorescence polarization immunoassay.
    Angelova EA, Minkova GD, Tsvetkova TZ.
    Clin Lab; 2006 Apr; 52(9-10):527-33. PubMed ID: 17078481
    [Abstract] [Full Text] [Related]

  • 13. Clinical usefulness of a HPLC method for simultaneous quantitation of plasma homocysteine and cysteine.
    Atamasirikul K, Kajanachumpol S, Wilairat P, Tantibhedhyangkul P.
    J Med Assoc Thai; 2008 Mar; 91(3):338-44. PubMed ID: 18575286
    [Abstract] [Full Text] [Related]

  • 14. An evaluation of an automated homocysteine method on the Bayer ADVIA Centaur automated chemiluminescent system.
    Mindicino HJ, Carlsen J, Tewari P, Aagaard O, Zhang B, Conarpe C.
    Clin Lab; 2002 Mar; 48(9-10):493-6. PubMed ID: 12389709
    [No Abstract] [Full Text] [Related]

  • 15. Evaluation of the Abbott IMx fluorescence polarization immunoassay and the bio-rad enzyme immunoassay for homocysteine: comparison with high-performance liquid chromatography.
    Donnelly JG, Pronovost C.
    Ann Clin Biochem; 2000 Mar; 37 ( Pt 2)():194-8. PubMed ID: 10735363
    [Abstract] [Full Text] [Related]

  • 16. Assessment of laboratory tests for plasma homocysteine--selected laboratories, July-September 1998.
    Centers for Disease Control and Prevention (CDC).
    MMWR Morb Mortal Wkly Rep; 1999 Nov 12; 48(44):1013-5. PubMed ID: 10577490
    [Abstract] [Full Text] [Related]

  • 17. Comparison of three methods for total homocysteine plasma determination.
    Brunelli T, Pepe G, Marcucci R, Giusti B, Prisco D, Abbate R, Fedi S.
    Clin Lab; 2001 Nov 12; 47(7-8):393-7. PubMed ID: 11499802
    [Abstract] [Full Text] [Related]

  • 18. Analytical evaluation of a new immunonephelometric method for homocysteine measurement.
    Zappacosta B, Persichilli S, Minucci A, Scribano D, Antenucci M, Fasanella S, Neri P, Giardina B, De Sole P.
    Clin Chim Acta; 2007 Jan 12; 375(1-2):165-8. PubMed ID: 16901478
    [Abstract] [Full Text] [Related]

  • 19. Performance of a new HIV 1/O/2 assay on the Bayer ADVIA Centaur immunoassay system.
    van Helden J, Denoyel G, Freeman J, Preisel-Simmons B.
    Clin Lab; 2004 Jan 12; 50(1-2):83-90. PubMed ID: 15000224
    [Abstract] [Full Text] [Related]

  • 20. An update on laboratory productivity with infectious disease assays on the Bayer ADVIA Centaur Immunoassay System.
    Dati F.
    Clin Lab; 2004 Jan 12; 50(1-2):53-61. PubMed ID: 15000221
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 8.