These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Merging parametric active contours within homogeneous image regions for MRI-based lung segmentation. Ray N, Acton ST, Altes T, de Lange EE, Brookeman JR. IEEE Trans Med Imaging; 2003 Feb; 22(2):189-99. PubMed ID: 12715995 [Abstract] [Full Text] [Related]
3. Steady-state free precession with hyperpolarized 3He: experiments and theory. Wild JM, Teh K, Woodhouse N, Paley MN, Fichele S, de Zanche N, Kasuboski L. J Magn Reson; 2006 Nov; 183(1):13-24. PubMed ID: 16890464 [Abstract] [Full Text] [Related]
4. Variable flip angle schedules in bSSFP imaging of hyperpolarized noble gases. Deppe MH, Wild JM. Magn Reson Med; 2012 Jun; 67(6):1656-64. PubMed ID: 22134846 [Abstract] [Full Text] [Related]
5. Measurement of pulmonary partial pressure of oxygen and oxygen depletion rate with hyperpolarized helium-3 MRI: a preliminary reproducibility study on pig model. Yu J, Rajaei S, Ishii M, Law M, Emami K, Woodburn JM, Kadlecek S, Vahdat V, Rizi RR. Acad Radiol; 2008 Jun; 15(6):702-12. PubMed ID: 18486007 [Abstract] [Full Text] [Related]
6. [Dynamic imaging of the nasal cavity and the paranasal sinuses with polarized 3helium MRI]. Hanke A, Gast K, Viallon M, Markstaller K, Eberle B, Thelen M, Kauczor HU. Rofo; 2001 Dec; 173(12):1126-30. PubMed ID: 11740674 [Abstract] [Full Text] [Related]
9. Progression of emphysema in a 12-month hyperpolarized 3He-MRI study: lacunarity analysis provided a more sensitive measure than standard ADC analysis. Diaz S, Casselbrant I, Piitulainen E, Magnusson P, Peterson B, Pickering E, Tuthill T, Ekberg O, Akeson P. Acad Radiol; 2009 Jun; 16(6):700-7. PubMed ID: 19362025 [Abstract] [Full Text] [Related]
10. The effects of SNR on ADC measurements in diffusion-weighted hyperpolarized He-3 MRI. O'Halloran RL, Holmes JH, Altes TA, Salerno M, Fain SB. J Magn Reson; 2007 Mar; 185(1):42-9. PubMed ID: 17150391 [Abstract] [Full Text] [Related]
12. Advantages of parallel imaging in conjunction with hyperpolarized helium--a new approach to MRI of the lung. Lee RF, Johnson G, Grossman RI, Stoeckel B, Trampel R, McGuinness G. Magn Reson Med; 2006 May; 55(5):1132-41. PubMed ID: 16586457 [Abstract] [Full Text] [Related]
17. Three-dimensional mapping of the B1 field using an optimized phase-based method: application to hyperpolarized 3He in lungs. Santoro D, Rivoire J, Meise F, Terekhov M, Salhi Z, Gast K, Schreiber LM. Magn Reson Med; 2011 Apr; 65(4):1166-72. PubMed ID: 21413081 [Abstract] [Full Text] [Related]
18. A flexible 32-channel receive array combined with a homogeneous transmit coil for human lung imaging with hyperpolarized 3He at 1.5 T. Deppe MH, Parra-Robles J, Marshall H, Lanz T, Wild JM. Magn Reson Med; 2011 Dec; 66(6):1788-97. PubMed ID: 21574180 [Abstract] [Full Text] [Related]
19. [Ultrafast MRI of lung ventilation using hyperpolarized helium-3]. Schreiber WG, Weiler N, Kauczor HU, Markstaller K, Eberle B, Hast J, Surkau R, Grossmann T, Deninger A, Hanisch G, Otten EW, Thelen M. Rofo; 2000 Feb; 172(2):129-33. PubMed ID: 10723485 [Abstract] [Full Text] [Related]
20. Rapid hyperpolarized 3He diffusion MRI of healthy and emphysematous human lungs using an optimized interleaved-spiral pulse sequence. Salerno M, Altes TA, Brookeman JR, de Lange EE, Mugler JP. J Magn Reson Imaging; 2003 May; 17(5):581-8. PubMed ID: 12720268 [Abstract] [Full Text] [Related] Page: [Next] [New Search]